Optimizing condenser fan control for air-cooled centrifugal chillers

被引:26
|
作者
Yu, F. W. [1 ]
Chan, K. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
关键词
air-cooled chiller; centrifugal compressor; coefficient of performance; electricity consumption;
D O I
10.1016/j.ijthermalsci.2007.07.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current design and operation of air-cooled condensers can cause a significant decrease in chiller performance under part load conditions. This paper demonstrates optimal condenser fan control to improve the coefficient of performance (COP) of air-cooled chillers. This control involves identifying the optimum set point of condensing temperature with the optimized power relationships of the compressors and condenser fans and enhancing the airflow and heat transfer area of the condensers. An example application of this control for an air-cooled centrifugal chiller indicated that the COP could increase by 11.4-237.2%, depending on the operating conditions. Such the increase of the COP results in a reduction of up to 14.1 kWh/m(2), or 27.3% in the annual electricity consumption per unit A/C floor area of chillers, given that the chillers serve an office building requiring an annual cooling energy per unit A/C floor area of 173.3 kWh/m(2). The simulation results of this study will give HVAC engineers a better understanding of how to optimize the design and operation of air-cooled chillers. (C) 2007 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:942 / 953
页数:12
相关论文
共 50 条
  • [41] CFD modelling of a thermal chimney for air-cooled condenser
    Li, Wenguang
    Yu, Guopeng
    Zagaglia, Daniele
    Green, Richard
    Yu, Zhibin
    GEOTHERMICS, 2020, 88
  • [42] Evaluation of a magnetic gear for air-cooled condenser applications
    Matthee, Alexander
    Wang, Rong-Jie
    Agenbach, Charles J.
    Els, Daniel N. J.
    Kamper, Maarten J.
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (05) : 677 - 683
  • [43] Varying duty operation of air-cooled condenser units
    Milman O.O.
    Kondratev A.V.
    Ptakhin A.V.
    Dunaev S.N.
    Kirjukhin A.V.
    Thermal Engineering, 2016, 63 (5) : 313 - 318
  • [44] PACKAGED AIR-COOLED CENTRIFUGAL CHILLER.
    Ishiguro, Toshihiko
    Hayashi, Masakatsu
    Hitachi Review, 1981, 30 (01): : 31 - 34
  • [45] Research on simulation model of direct air-cooled condenser
    Yan, Qin
    Xu, Er-Shu
    Yang, Yong-Ping
    Ma, Liang-Yu
    Wang, Bing-Shu
    Dongli Gongcheng/Power Engineering, 2008, 28 (03): : 381 - 385
  • [46] Optimum Operation of Air-Cooled Chillers with Multiple Refrigeration Circuits
    Yang, Jia
    Chan, K. T.
    Wu, Xiangsheng
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 460 - 467
  • [47] EFFECT OF TIP VORTEX REDUCTION ON AIR-COOLED CONDENSER AXIAL FLOW FAN PERFORMANCE: AN EXPERIMENTAL INVESTIGATION
    Pretorius, J. P.
    Erasmus, J. A.
    PROCEEDINGS OF ASME TURBO EXPO 2021: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 1, 2021,
  • [48] Improved energy performance of air-cooled water chillers with innovative condenser coil configurations - Part II: Experimental validation
    Lee, Tzong-Shing
    Wu, Wu-Chieh
    Jiang, Jin-Cheng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2212 - 2222
  • [49] Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser
    Hajidavalloo, E.
    Eghtedari, H.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (05): : 982 - 988
  • [50] Effect of Tip Vortex Reduction on Air-Cooled Condenser Axial Flow Fan Performance: An Experimental Investigation
    Pretorius, Johannes P.
    Erasmus, Johan A.
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2022, 144 (03):