Development of two-grating spectrometer for the charge exchange spectroscopy system on KSTAR

被引:7
|
作者
Lee, Hyungho [1 ,2 ]
Song, Eun-ji [3 ]
Park, Young-dong [4 ]
Oh, Soo-ghee [3 ]
Ko, Won-Ha [1 ]
机构
[1] NFRI, Taejon 305333, South Korea
[2] Univ Sci & Technol, Dept Nucl Fus & Plasma Sci, Taejon 305350, South Korea
[3] Ajou Univ, Div Energy Syst Res, Suwon 443749, South Korea
[4] Ajou Univ, Dept Chem, Suwon 443749, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2011年 / 82卷 / 06期
关键词
PLASMA ION TEMPERATURE;
D O I
10.1063/1.3606438
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The charge exchange spectroscopy (CES) system on Korea Superconducting Tokamak Advanced Research (KSTAR) was installed last year and had been applied to measure the C VI ion temperature and rotation velocity profiles. The ion temperature and rotation velocity profiles had been estimated from the C VI 5290.5 angstrom (n = 8-7) charge-exchange spectrum signal measured by a Czerny-Turner type spectrometer and a thinned back-illuminated charge coupled device (CCD) camera. However, the Czerny-Turner type spectrometer used for the KSTAR CES system showed so low signal to noise ratio for KSTAR plasmas in the 2010 experimental campaign that the time resolution of the CES system had been limited to 100 ms due to the increased exposure time of the attached CCD camera. Then, new two-grating spectrometer had been developed in order to improve the time resolution of the CES system. The spectrometer consists of two gratings (1200 g/mm and 1800 g/mm each) with additive configuration, concave mirrors (f = 50 cm), and a cylindrical lens (f = 50 cm). The time resolution of the CES system increases by a factor of 2-4 with the two-grating spectrometer. The C VI ion temperature and rotation velocity profiles obtained by the two-grating spectrometer are compared to those by Czerny-Turner type spectrometer in this paper. (C) 2011 American Institute of Physics. [doi:10.1063/1.3606438]
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER
    A. P. Kuznetsov
    O. I. Buzinskij
    K. L. Gubsky
    E. A. Nikitina
    A. V. Savchenkov
    B. A. Tarasov
    S. N. Tugarinov
    Physics of Atomic Nuclei, 2015, 78 : 1677 - 1685
  • [42] A near X-point charge exchange neutral spectroscopy (CENS) system for DIII-D
    Haskey, S. R.
    Chrystal, C.
    Angulo, A.
    Bortolon, A.
    Wolfe, E.
    Linsenmayer, E.
    Marini, C.
    Scotti, F.
    Agustin, K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (09):
  • [43] Overview on R&D and design activities for the ITER core charge exchange spectroscopy diagnostic system
    Biel, W.
    Baross, T.
    Bourauel, P.
    Dunai, D.
    Durkut, M.
    Erdei, G.
    Hawkes, N.
    v. Hellermann, M.
    Hogenbirk, A.
    Jaspers, R.
    Kiss, G.
    Klinkhamer, F.
    Koning, J. F.
    Kotov, V.
    Krasikov, Y.
    Krimmer, A.
    Lischtschenko, O.
    Litnovsky, A.
    Marchuk, O.
    Neubauer, O.
    Offermanns, G.
    Panin, A.
    Patel, K.
    Pokol, G.
    Schrader, M.
    Snijders, B.
    Szabo, V.
    van der Valk, N.
    Voinchet, R.
    Wolters, J.
    Zoletnik, S.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 548 - 551
  • [44] Toner surface-charge density and development efficiency in the two-component development system
    Takahashi, S.
    Kobayashi, N.
    Yamazaki, T.
    Proceedings of the International Congress on Advances in Non-Impact Printing Technologies, 1991,
  • [45] Development of Laboratory Experimental System to Clarify Solar Wind Charge Exchange Mechanism with TES Microcalorimeter
    Enoki, T.
    Ishisaki, Y.
    Akamatsu, H.
    Ezoe, Y.
    Ohashi, T.
    Kanda, T.
    Ishida, T.
    Tanuma, H.
    Ohashi, H.
    Shinozaki, K.
    Mitsuda, K.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (5-6) : 771 - 776
  • [46] Development of Laboratory Experimental System to Clarify Solar Wind Charge Exchange Mechanism with TES Microcalorimeter
    T. Enoki
    Y. Ishisaki
    H. Akamatsu
    Y. Ezoe
    T. Ohashi
    T. Kanda
    T. Ishida
    H. Tanuma
    H. Ohashi
    K. Shinozaki
    K. Mitsuda
    Journal of Low Temperature Physics, 2012, 167 : 771 - 776
  • [47] Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge
    Churchill, R. M.
    Theiler, C.
    Lipschultz, B.
    Dux, R.
    Puetterich, T.
    Viezzer, E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (09):
  • [48] Grating spectrometer system for beam emission spectroscopy diagnostics using high-energy negative-ion-based neutral beam injection on LHD
    Kado, S.
    Oishi, T.
    Yoshinuma, M.
    Ida, K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [49] Development of a charge exchange recombination spectroscopy method for determination of ion temperature from Hα line broadening in the Hanbit mirror device
    Yoo, SJ
    Yang, HL
    Na, HK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 2119 - 2122
  • [50] Spectroscopy of a Cooper-pair box coupled to a two-level system via charge and critical current
    Zaretskey, V.
    Suri, B.
    Novikov, S.
    Wellstood, F. C.
    Palmer, B. S.
    PHYSICAL REVIEW B, 2013, 87 (17):