Development of two-grating spectrometer for the charge exchange spectroscopy system on KSTAR

被引:7
|
作者
Lee, Hyungho [1 ,2 ]
Song, Eun-ji [3 ]
Park, Young-dong [4 ]
Oh, Soo-ghee [3 ]
Ko, Won-Ha [1 ]
机构
[1] NFRI, Taejon 305333, South Korea
[2] Univ Sci & Technol, Dept Nucl Fus & Plasma Sci, Taejon 305350, South Korea
[3] Ajou Univ, Div Energy Syst Res, Suwon 443749, South Korea
[4] Ajou Univ, Dept Chem, Suwon 443749, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2011年 / 82卷 / 06期
关键词
PLASMA ION TEMPERATURE;
D O I
10.1063/1.3606438
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The charge exchange spectroscopy (CES) system on Korea Superconducting Tokamak Advanced Research (KSTAR) was installed last year and had been applied to measure the C VI ion temperature and rotation velocity profiles. The ion temperature and rotation velocity profiles had been estimated from the C VI 5290.5 angstrom (n = 8-7) charge-exchange spectrum signal measured by a Czerny-Turner type spectrometer and a thinned back-illuminated charge coupled device (CCD) camera. However, the Czerny-Turner type spectrometer used for the KSTAR CES system showed so low signal to noise ratio for KSTAR plasmas in the 2010 experimental campaign that the time resolution of the CES system had been limited to 100 ms due to the increased exposure time of the attached CCD camera. Then, new two-grating spectrometer had been developed in order to improve the time resolution of the CES system. The spectrometer consists of two gratings (1200 g/mm and 1800 g/mm each) with additive configuration, concave mirrors (f = 50 cm), and a cylindrical lens (f = 50 cm). The time resolution of the CES system increases by a factor of 2-4 with the two-grating spectrometer. The C VI ion temperature and rotation velocity profiles obtained by the two-grating spectrometer are compared to those by Czerny-Turner type spectrometer in this paper. (C) 2011 American Institute of Physics. [doi:10.1063/1.3606438]
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A visible and UV charge exchange spectroscopy system for the tritium phase of JET
    Morsi, HW
    vonHellermann, M
    Konig, RWT
    Schropf, H
    PLASMA PHYSICS AND CONTROLLED FUSION, 1995, 37 (12) : 1407 - 1431
  • [22] Design of combined system of helium charge exchange spectroscopy and hydrogen beam emission spectroscopy in VEST
    Kim, YooSung
    Shi, Yue-Jiang
    Lee, Kihyun
    Oh, Soo-Ghee
    von Hellermann, Manfred
    Chung, Kyoung-Jae
    Hwang, Y. S.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 975 - 978
  • [23] Fast charge exchange spectroscopy using a Fabry-Perot spectrometer in the JIPP TII-U tokamak
    Ida, K
    Xu, J
    Sato, KN
    Sakakita, H
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 219 - 223
  • [24] Enhanced core charge exchange recombination spectroscopy system on Joint European Torus
    Negus, C. R.
    Giroud, C.
    Meigs, A. G.
    Zastrow, K. -D.
    Hillis, D. L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [25] A fast edge charge exchange recombination spectroscopy system at the ASDEX Upgrade tokamak
    Cavedon, M.
    Puetterich, T.
    Viezzer, E.
    Dux, R.
    Geiger, B.
    McDermott, R. M.
    Meyer, H.
    Stroth, U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (04):
  • [26] Study of the ηη system in the π-p charge exchange reaction at 32 GeV/c with the GAMS-4π spectrometer
    Blick, AM
    Binon, FG
    Dolgopolov, A
    Donskov, S
    Inaba, S
    Fujii, Y
    Khaustov, G
    Kolosov, VN
    Kondashov, AA
    Lednev, AA
    Lishin, VA
    Peigneux, JP
    Polyakov, VA
    Sadovsky, SA
    Samoylenko, VD
    Shagin, PM
    Shimizu, H
    Singovsky, AV
    Sobol, AE
    Stroot, JP
    Sugonyaev, VP
    Takamatsu, K
    Tsuru, T
    Yasu, Y
    Zvyagin, AY
    HADRON SPECTROSCOPY, 2002, 619 : 637 - 640
  • [27] Development of Ar+16 charge exchange recombination spectroscopy measurements at ASDEX Upgrade
    McDermott, R. M.
    Dux, R.
    Guzman, F.
    Puetterich, T.
    Fischer, R.
    Kappatou, A.
    NUCLEAR FUSION, 2021, 61 (01)
  • [28] The development of charge exchange recombination spectroscopy diagnostics for the T-15MD tokamak
    Krupin, V.
    Zemtsov, I.
    Nurgaliev, M.
    Klyuchnikov, L.
    Nemets, A.
    Ivanov, A.
    Stupishin, N.
    Naumenko, N.
    Tugarinov, S.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (02):
  • [29] The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak
    刘亮
    余德良
    马倩
    何小斐
    Maarten DE BOCK
    Manfred von HELLERMANN
    Michael WALSH
    陈文锦
    何小雪
    魏彦玲
    张能
    李栋
    魏会领
    the HL-2A Team
    Plasma Science and Technology, 2024, (06) : 108 - 115
  • [30] The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak
    刘亮
    余德良
    马倩
    何小斐
    Maarten DE BOCK
    Manfred von HELLERMANN
    Michael WALSH
    陈文锦
    何小雪
    魏彦玲
    张能
    李栋
    魏会领
    the HLA Team
    Plasma Science and Technology, 2024, 26 (06) : 108 - 115