Development of two-grating spectrometer for the charge exchange spectroscopy system on KSTAR

被引:7
|
作者
Lee, Hyungho [1 ,2 ]
Song, Eun-ji [3 ]
Park, Young-dong [4 ]
Oh, Soo-ghee [3 ]
Ko, Won-Ha [1 ]
机构
[1] NFRI, Taejon 305333, South Korea
[2] Univ Sci & Technol, Dept Nucl Fus & Plasma Sci, Taejon 305350, South Korea
[3] Ajou Univ, Div Energy Syst Res, Suwon 443749, South Korea
[4] Ajou Univ, Dept Chem, Suwon 443749, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2011年 / 82卷 / 06期
关键词
PLASMA ION TEMPERATURE;
D O I
10.1063/1.3606438
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The charge exchange spectroscopy (CES) system on Korea Superconducting Tokamak Advanced Research (KSTAR) was installed last year and had been applied to measure the C VI ion temperature and rotation velocity profiles. The ion temperature and rotation velocity profiles had been estimated from the C VI 5290.5 angstrom (n = 8-7) charge-exchange spectrum signal measured by a Czerny-Turner type spectrometer and a thinned back-illuminated charge coupled device (CCD) camera. However, the Czerny-Turner type spectrometer used for the KSTAR CES system showed so low signal to noise ratio for KSTAR plasmas in the 2010 experimental campaign that the time resolution of the CES system had been limited to 100 ms due to the increased exposure time of the attached CCD camera. Then, new two-grating spectrometer had been developed in order to improve the time resolution of the CES system. The spectrometer consists of two gratings (1200 g/mm and 1800 g/mm each) with additive configuration, concave mirrors (f = 50 cm), and a cylindrical lens (f = 50 cm). The time resolution of the CES system increases by a factor of 2-4 with the two-grating spectrometer. The C VI ion temperature and rotation velocity profiles obtained by the two-grating spectrometer are compared to those by Czerny-Turner type spectrometer in this paper. (C) 2011 American Institute of Physics. [doi:10.1063/1.3606438]
引用
收藏
页数:5
相关论文
共 50 条
  • [31] The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak
    Liu, Liang
    Yu, Deliang
    Ma, Qian
    He, Xiaofei
    De Bock, Maarten
    von Hellermann, Manfred
    Walsh, Michael
    Chen, Wenjin
    He, Xiaoxue
    Wei, Yanling
    Zhang, Neng
    Li, Dong
    Wei, Huiling
    PLASMA SCIENCE & TECHNOLOGY, 2024, 26 (06)
  • [32] Improved charge coupled device detectors for the edge charge exchange spectroscopy system on the DIII-D tokamak
    Burrell, KH
    Kaplan, DH
    Gohil, P
    Nilson, DG
    Groebner, RJ
    Thomas, DM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 1028 - 1033
  • [33] Wavelength calibration of the charge exchange recombination spectroscopy system on the DIII-D tokamak
    Gohil, P
    Burrell, KH
    Groebner, RJ
    Holtrop, K
    Kaplan, DH
    Monier-Garbet, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 878 - 881
  • [34] Impurity density profile measurements with a fast filter spectrometer and a modulated diagnostic beam on Tore Supra by charge exchange recombination spectroscopy
    Hess, WR
    Farjon, JL
    Guirlet, R
    Druetta, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (04): : 1775 - 1778
  • [35] Development of the charge exchange type beam scraper system at the J-PARC
    Okabe, K.
    Yamamoto, K.
    Kinsho, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 811 : 11 - 17
  • [36] Technology of near infrared spectroscopy analysis system design based on fixed grating and charge-coupled device
    Zhang, Yinqiao
    Zhao, Bo
    Wang, Hui
    Mao, Wenhua
    Zhang, Xiaochao
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2009, 25 (09): : 176 - 181
  • [37] Feasibility study for an edge main ion charge exchange recombination spectroscopy system at ASDEX Upgrade
    Cano-Megias, P.
    Viezzer, E.
    van Vuuren, A. Jansen
    Cavedon, M.
    Cruz-Zabala, D. J.
    Dux, R.
    Geiger, B.
    Garcia-Munoz, M.
    Chacartegui, R.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [38] Upgrade of the edge Charge Exchange Recombination Spectroscopy system at the High Field Side of ASDEX Upgrade
    Cruz-Zabala, D. J.
    Viezzer, E.
    Griener, M.
    Plank, U.
    Cavedon, M.
    Cano-Megias, P.
    Dux, R.
    Fuchert, G.
    Garcia-Lopez, J.
    Garcia-Munoz, M.
    van Vuuren, A. Jansen
    Puetterich, T.
    Rohde, V
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [39] Optical system design for the charge exchange spectroscopy of the Korea superconducting tokamak advanced research device
    Oh, Seungtae
    Ko, Won-Ha
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (04)
  • [40] Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER
    Kuznetsov, A. P.
    Buzinskij, O. I.
    Gubsky, K. L.
    Nikitina, E. A.
    Savchenkov, A. V.
    Tarasov, B. A.
    Tugarinov, S. N.
    PHYSICS OF ATOMIC NUCLEI, 2015, 78 (14) : 1677 - 1685