Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: A three-dimensional finite element analysis

被引:9
|
作者
Yan, Xu [1 ]
Zhang, Xinwen [2 ]
Chi, Weichao [3 ]
Ai, Hongjun [1 ]
Wu, Lin [1 ]
机构
[1] China Med Univ, Sch Stomatol, Dept Prosthodont, Shenyang 110001, Peoples R China
[2] China Med Univ, Sch Stomatol, Ctr Implant Dent, Shenyang 110001, Peoples R China
[3] Harbin Inst Technol, Sch Astronaut, Harbin 150006, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
finite element analysis; bi-cortical implant; stress distribution; resonance frequencies; sinus floor; BRANEMARK SYSTEM IMPLANTS; PRIMARY STABILITY; IN-VITRO; NUMERICAL APPROACH; ORAL IMPLANTS; ELEVATION TECHNIQUE; FIXED PROSTHESIS; ANCHORAGE; STRESS; PLACEMENT;
D O I
10.3109/00016357.2014.967718
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. This study aimed to compare the influence of alveolar ridge cortical bone and sinus floor cortical bone in sinus areabi-cortical dental implantation by means of 3D finite element analysis. Materials and methods. Three-dimensional finite element (FE) models in a posterior maxillary region with sinus membrane and the same height of alveolar ridge of 10 mm were generated according to the anatomical data of the sinus area. They were either with fixed thickness of crestal cortical bone and variable thickness of sinus floor cortical bone or vice versa. Ten models were assumed to be under immediate loading or conventional loading. The standard implant model based on the Nobel Biocare implant system was created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. An inclined force of 129 N was applied. Results. Von Mises stress mainly concentrated on the surface of crestal cortical bone around the implant neck. For all the models, both the axial and buccolingual resonance frequencies of conventional loading were higher than those of immediate loading; however, the difference is less than 5%. Conclusion. The results showed that bi-cortical implant in sinus area increased the stability of the implant, especially for immediately loading implantation. The thickness of both crestal cortical bone and sinus floor cortical bone influenced implant micromotion and stress distribution; however, crestal cortical bone may be more important than sinus floor cortical bone.
引用
收藏
页码:312 / 320
页数:9
相关论文
共 50 条
  • [31] Effect of dental implant cross-sectional design on cortical bone structure using finite element analysis
    Abu-Hammad, Osama
    Khraisat, Ameen
    Dar-Odeh, Najla
    El-Maaytah, Mohammed
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (04) : 217 - 221
  • [32] Comparison of Conventional and Pontic Fixed Partial Dentures Over Implants Using the Finite Element Method: Three-Dimensional Analysis of Cortical and Medullary Bone Stress
    Toniollo, Marcelo Bighetti
    Sa, Mikaelly dos Santos
    Silva, Fernanda Pereira
    Reis, Giselle Rodrigues
    Macedo, Ana Paula
    Terada, Andrea Sayuri Silveira Dias
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 175 - 181
  • [33] Cortical Bone Stress Distribution in Mandibles with Different Configurations Restored with Prefabricated Bar-Prosthesis Protocol: A Three-Dimensional Finite-Element Analysis
    de Almeida, Erika Oliveira
    Rocha, Eduardo Passos
    Assuncao, Wirley Goncalves
    Freitas Junior, Amilcar Chagas
    Anchieta, Rodolfo Bruniera
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (01): : 29 - 34
  • [34] Biomechanical Analysis of Grafted and Nongrafted Maxillary Sinus Augmentation in the Atrophic Posterior Maxilla with Three-Dimensional Finite Element Method
    Wang, Xuan
    Zhang, Tianqi
    Yang, Enli
    Gong, Zhiyuan
    Shen, Hongzhou
    Wu, Haiwei
    Zhang, Dongsheng
    SCANNING, 2020, 2020
  • [35] Influence of Fine Threads and Platform-Switching on Crestal Bone Stress Around Implant-A Three-Dimensional Finite Element Analysis
    Khurana, Pardeep
    Sharma, Arun
    Sodhi, Kiranmeet Kaur
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (06) : 697 - 703
  • [36] THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS
    Baggi, Luigi
    Cappelloni, Ilaria
    Di Girolamo, Michele
    Maceri, Franco
    Vairo, Giuseppe
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06): : 422 - 431
  • [37] Image based finite element modeling of the three-point bending test of cortical bone
    Binkowski, Marcin
    Kokot, Grzegorz
    Bolechala, Filip
    John, Antoni
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [39] Three-dimensional mapping of cortical bone thickness in subjects with different vertical facial dimensions
    Sadek, Mais Medhat
    Sabet, Noha Ezat
    Hassan, Islam Tarek
    PROGRESS IN ORTHODONTICS, 2016, 17
  • [40] Three-dimensional mapping of cortical bone thickness in subjects with different vertical facial dimensions
    Mais Medhat Sadek
    Noha Ezat Sabet
    Islam Tarek Hassan
    Progress in Orthodontics, 17