Effect of dental implant cross-sectional design on cortical bone structure using finite element analysis

被引:14
|
作者
Abu-Hammad, Osama
Khraisat, Ameen
Dar-Odeh, Najla
El-Maaytah, Mohammed
机构
[1] Univ Jordan, Fac Dent, Dept Conservat Dent & Prosthodont, Amman, Jordan
[2] Univ Jordan, Fac Dent, Dept Oral Med Oral Surg & Periodont, Amman, Jordan
[3] UCL Hosp, Oral & Maxillofacial Surg Head & Neck Unit, London, England
[4] Eastman Dent Inst, Div Maxillofacial Diagnost Med & Surg Sci, London, England
关键词
implant design; implant thread; bone stress; strain; implant diameter; finite element analysis;
D O I
10.1111/j.1708-8208.2007.00048.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This finite element analysis investigation evaluated the effect of different implant cross-sectional designs on bone stress levels under different loading patterns. Materials and Methods: Finite element analysis program was used to construct four different three-dimensional models describing 4 x 10-mm implants in blocks of cortical and trabecular bone. A 5-mm-long abutment was modeled above each implant. The implant in model 1 was unthreaded, while in model 2 the implant was circularly threaded. The third implant in model 3 had the cross-sectional shape as a 16-sided star-shaped design. The implant in model 4 was constructed unthreaded, with a diameter of 4.5mm. Vertical and horizontal loads of 100 N each were applied on the top middle node of each implant assembly. All nodes at the bottom surface of the bone models were restrained. Results: By comparing models 1, 2, and 3, the lowest bone stress values under vertical and horizontal forces were observed around the unthreaded implant in model 1 (8.92 and 94.52MPa, respectively). The highest stress value under vertical loading was shown around the threaded implant in model 2 (10.07MPa), whereas the highest stress value under horizontal loading was observed around the star-shaped implant in model 3 (108.40MPa). Model 4, with a wider unthreaded design, had stress values under vertical and horizontal loading of 7.32 and 71.35MPa, respectively. Conclusions: It was concluded that the unthreaded implant design produced the least bone stress. An increase in implant diameter could produce marked reduction in stress value in the bone around the neck of the implant.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 50 条
  • [1] Effect of the Number of Dental Implant Neck Threads in Contact with the Cortical Bone on Interface Stresses Using Finite Element Method
    Hassan, Mohammed Moustafa
    El-Wakad, Moahamed-Tarek
    Bakr, E. M.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3A, 2014,
  • [2] An Optimized Dental Implant Model Using Finite Element Analysis and Design of Experiment
    Srivastava, Sambhrant
    Sarangi, Saroj Kumar
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 142 - 149
  • [3] Finite element analysis of gradient lattice structure patterns for bone implant design
    Seharing, Asliah
    Azman, Abdul Hadi
    Abdullah, Shahrum
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2020, 11 (04) : 535 - 545
  • [4] ANALYSIS OF A DENTAL IMPLANT USING FINITE ELEMENT METHOD
    Vlasceanu, Daniel
    Petrescu, Ioana
    Comaneanu, Raluca Monica
    Tarcolea, Mihai
    Cotrut, Mihai Cosmin
    [J]. ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1277 - 1278
  • [5] Effect of Short Dental Implant Material on Bone Stress: An In Vitro Finite Element Analysis
    Al Qahtani, Waleed M. S.
    [J]. JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1781 - 1786
  • [6] Influence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study
    Londono, J. J.
    Ramos, A.
    Correa, S.
    Mesnard, M.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 : S178 - S179
  • [7] Design of dental implant using design of experiment and topology optimization: A finite element analysis study
    Gupta, Yash
    Iyer, Rohit
    Dommeti, Vamsi Krishna
    Nutu, Emil
    Rana, Masud
    Merdji, Ali
    Biswas, Jayanta Kumar
    Roy, Sandipan
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (02) : 157 - 166
  • [8] Investigating a Novel Design Dental Implant by Using Finite Element Analysis and Experimental Setup
    Sen, Yasar
    [J]. JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2020, 10 (07) : 915 - 921
  • [9] Association between Age of Menopause and Thickness of Crestal Cortical Bone at Dental Implant Site: A Cross-Sectional Observational Study
    Ko, Yi-Chun
    Tsai, Ming-Tzu
    Fuh, Lih-Jyh
    Tsai, Min-Jia
    Wang, Xuan-Hui
    Huang, Heng-Li
    Hsu, Jui-Ting
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (16) : 1 - 9
  • [10] Effect of bone quality and osseointegration on stress distribution in the bone tissue surrounding dental implant: a finite element analysis
    Kasari, M. Shabanpour
    Yousefi, H.
    Shirazi, Emamian
    Geramy, A.
    [J]. JOURNAL OF OSSEOINTEGRATION, 2023, 15 (02) : 106 - 112