Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: A three-dimensional finite element analysis

被引:9
|
作者
Yan, Xu [1 ]
Zhang, Xinwen [2 ]
Chi, Weichao [3 ]
Ai, Hongjun [1 ]
Wu, Lin [1 ]
机构
[1] China Med Univ, Sch Stomatol, Dept Prosthodont, Shenyang 110001, Peoples R China
[2] China Med Univ, Sch Stomatol, Ctr Implant Dent, Shenyang 110001, Peoples R China
[3] Harbin Inst Technol, Sch Astronaut, Harbin 150006, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
finite element analysis; bi-cortical implant; stress distribution; resonance frequencies; sinus floor; BRANEMARK SYSTEM IMPLANTS; PRIMARY STABILITY; IN-VITRO; NUMERICAL APPROACH; ORAL IMPLANTS; ELEVATION TECHNIQUE; FIXED PROSTHESIS; ANCHORAGE; STRESS; PLACEMENT;
D O I
10.3109/00016357.2014.967718
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. This study aimed to compare the influence of alveolar ridge cortical bone and sinus floor cortical bone in sinus areabi-cortical dental implantation by means of 3D finite element analysis. Materials and methods. Three-dimensional finite element (FE) models in a posterior maxillary region with sinus membrane and the same height of alveolar ridge of 10 mm were generated according to the anatomical data of the sinus area. They were either with fixed thickness of crestal cortical bone and variable thickness of sinus floor cortical bone or vice versa. Ten models were assumed to be under immediate loading or conventional loading. The standard implant model based on the Nobel Biocare implant system was created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. An inclined force of 129 N was applied. Results. Von Mises stress mainly concentrated on the surface of crestal cortical bone around the implant neck. For all the models, both the axial and buccolingual resonance frequencies of conventional loading were higher than those of immediate loading; however, the difference is less than 5%. Conclusion. The results showed that bi-cortical implant in sinus area increased the stability of the implant, especially for immediately loading implantation. The thickness of both crestal cortical bone and sinus floor cortical bone influenced implant micromotion and stress distribution; however, crestal cortical bone may be more important than sinus floor cortical bone.
引用
收藏
页码:312 / 320
页数:9
相关论文
共 50 条
  • [41] Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models
    Bossy, E. (emmanuel.bossy@lip.bhdc.jussieu.fr), 1600, Acoustical Society of America (115):
  • [42] A method for measuring the three-dimensional orientation of cortical canals with implications for comparative analysis of bone microstructure in vertebrates
    Pratt, Isaac Vorster
    Cooper, David Michael Lane
    MICRON, 2017, 92 : 32 - 38
  • [43] Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models
    Bossy, E
    Talmant, M
    Laugier, P
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (05): : 2314 - 2324
  • [44] Comparing Cortical Bone Trajectories for Pedicle Screw Insertion using Robotic Guidance and Three-Dimensional Computed Tomography Navigation
    Khan, Asham
    Rho, Kyungduk
    Mao, Jennifer Z.
    O'Connor, Timothy E.
    Agyei, Justice O.
    Meyers, Joshua E.
    Mullin, Jeffrey P.
    Pollina, John
    WORLD NEUROSURGERY, 2020, 141 : E625 - E632
  • [45] Technology of Cortical Bone Trajectory on the Influence of Stability in Fixation of Burst Fracture of Thoracolumbar Spine: A Finite Element Analysis
    Wang, Jianping
    Gu, Juping
    Zhao, Jian
    Zhang, Xinsong
    Hua, Liang
    Zhou, Chunfeng
    ADVANCED COMPUTATIONAL METHODS IN LIFE SYSTEM MODELING AND SIMULATION, LSMS 2017, PT I, 2017, 761 : 104 - 112
  • [46] Finite Element Analysis of Cortical Bone Trajectory Screw Resistance to Pullout During Exposure to Different Cortical Layers Based on AbaqusCEA Software
    Wu, Changbing
    Long, Hao
    Fu, Yong
    He, Zubo
    Liu, Jie
    Xu, Zihang
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (08) : 1329 - 1337
  • [47] Finite Element Analysis of Cortical Bone Trajectory Screw Resistance to Pullout During Exposure to Different Cortical Layers Based on AbaqusCEA Software
    Changbing Wu
    Hao Long
    Yong Fu
    Zubo He
    Jie Liu
    Zihang Xu
    Indian Journal of Orthopaedics, 2023, 57 : 1329 - 1337
  • [48] Influence of Implant Length and Diameter, Bicortical Anchorage, and Sinus Augmentation on Bone Stress Distribution: Three-Dimensional Finite Element Analysis
    Moriwaki, Hiroyoshi
    Yamaguchi, Satoshi
    Nakano, Tamaki
    Yamanishi, Yasufumi
    Imazato, Satoshi
    Yatani, Hirofumi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : E84 - E91
  • [49] Thermomechanical damage in cortical bone caused by margins of surgical drill bit: A finite element analysis
    Akhbar, Mohd Faizal Ali
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 231
  • [50] 3D Finite-Element Modelling of Drilling Cortical Bone: Temperature Analysis
    Alam, Khurshid
    Khan, Mushtaq
    Silberschmidt, Vadim V.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (06) : 618 - 623