Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure

被引:378
|
作者
Weber, Thomas [1 ,2 ]
Wassertheurer, Siegfried [3 ,4 ]
Rammer, Martin [1 ]
Maurer, Edwin [1 ]
Hametner, Bernhard [3 ]
Mayer, Christopher C. [3 ]
Kropf, Johannes [3 ,4 ]
Eber, Bernd [1 ]
机构
[1] Klinikum Wels Grieskirchen, Dept Cardiol, A-4600 Wels, Austria
[2] Paracelsus Med Univ, Salzburg, Austria
[3] Austrian Inst Technol, Hlth & Environm Dept, Vienna, Austria
[4] Vienna Univ Technol, Inst Anal & Sci Comp, A-1040 Vienna, Austria
关键词
central systolic blood pressure; oscillometric blood pressure monitor; arterial waveforms; validation study; CENTRAL AORTIC PRESSURE; PREDICTS CARDIOVASCULAR EVENTS; GENERALIZED TRANSFER-FUNCTION; PULSE PRESSURE; ARTERIAL STIFFNESS; IMPACT; DRUGS; RISK;
D O I
10.1161/HYPERTENSIONAHA.111.176313
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The prognostic value of central systolic blood pressure has been established recently. At present, its noninvasive assessment is limited by the need of dedicated equipment and trained operators. Moreover, ambulatory and home blood pressure monitoring of central pressures are not feasible. An algorithm enabling conventional automated oscillometric blood pressure monitors to assess central systolic pressure could be of value. We compared central systolic pressure, calculated with a transfer-function like method (ARCSolver algorithm), using waveforms recorded with a regular oscillometric cuff suitable for ambulatory measurements, with simultaneous high-fidelity invasive recordings, and with noninvasive estimations using a validated device, operating with radial tonometry and a generalized transfer function. Both studies revealed a good agreement between the oscillometric cuff-based central systolic pressure and the comparator. In the invasive study, composed of 30 patients, mean difference between oscillometric cuff/ARCSolver-based and invasive central systolic pressures was 3.0 mm Hg (SD: 6.0 mm Hg) with invasive calibration of brachial waveforms and -3.0 mm Hg (SD: 9.5 mm Hg) with noninvasive calibration of brachial waveforms. Results were similar when the reference method (radial tonometry/transfer function) was compared with invasive measurements. In the noninvasive study, composed of 111 patients, mean difference between oscillometric cuff/ARCSolver-derived and radial tonometry/transfer function-derived central systolic pressures was -0.5 mm Hg (SD: 4.7 mm Hg). In conclusion, a novel transfer function-like algorithm, using brachial cuff-based waveform recordings, is suited to provide a realistic estimation of central systolic pressure. (Hypertension. 2011;58:825-832.). Online Data Supplement
引用
收藏
页码:825 / U317
页数:11
相关论文
共 50 条
  • [21] CUFF-BASED AND INTRAARTERIAL BRACHIAL BLOOD PRESSURE MISMATCH AND ITS POTENTIAL IMPACT ON ANTIHYPERTENSIVE TREATMENT AND ESTIMATION OF AORTIC BLOOD PRESSURE
    Goupil, Remi
    Kowalski, Cedric
    Yang, Katie
    Charron, Thierry
    Doucet, Michel
    Hatem, Raja
    Kouz, Remi
    Palisaitis, Donald
    Schampaert, Erick
    Terriault, Paul
    Tessier, Pierre
    Agharazii, Mohsen
    JOURNAL OF HYPERTENSION, 2021, 39 : E409 - E409
  • [22] Arterial pressure: agreement between a brachial cuff-based device and radial tonometry
    Park, Chloe M.
    Korolkova, Olga
    Davies, Justin E.
    Parker, Kim H.
    Siggers, Jennifer H.
    March, Katherine
    Tillin, Therese
    Chaturvedi, Nish
    Hughes, Alun D.
    JOURNAL OF HYPERTENSION, 2014, 32 (04) : 865 - 872
  • [23] Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure
    Bia, Daniel
    Salazar, Federico
    Cinca, Luis
    Gutierrez, Marcos
    Facta, Alvaro
    Diaz, Alejandro
    Zocalo, Yanina
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2024, 44 (03) : 228 - 239
  • [24] Relationship between brachial blood pressure obtained by cuff method and central blood pressure measured with invasive method
    Kobayashi, H.
    Kino, M.
    Hokama, Y.
    Ohshima, K.
    Sugo, Y.
    Kojima, I.
    Miyawaki, Y.
    Takazawa, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 265 - 265
  • [25] Blood Pressure Estimation Algorithm by a Cuff-Based Monitoring Unit
    Lopez-Lozada, Elizabeth
    Perez-Martinez, David
    Barragan-Vazquez, Diana Patricia
    Montiel-Perez, Yalja
    Sossa-Azuela, Juan Humberto
    COMPUTACION Y SISTEMAS, 2023, 27 (04): : 1047 - 1056
  • [26] Comparison between cuff-based and radial tonometry exercise-induced central blood pressure
    Morales-Acuna, Francisco
    Ratcliffe, Brycen
    Harrison, Caleb
    Crowe, Sierra
    Bockover, Evan
    Pawlak, Robert
    Gurovich, Alvaro N.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (04) : 901 - 911
  • [27] Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring
    Man, Ping-Kwan
    Cheung, Kit-Leong
    Sangsiri, Nawapon
    Shek, Wilfred Jin
    Wong, Kwan-Long
    Chin, Jing-Wei
    Chan, Tsz-Tai
    So, Richard Hau-Yue
    HEALTHCARE, 2022, 10 (10)
  • [28] The effect of arterial stiffness on cuff-based blood pressure measurement
    Ma, Yuxiang
    Chen, Ying
    Ma, Yinji
    Feng, Xue
    EXTREME MECHANICS LETTERS, 2021, 48
  • [29] A New Method to Estimate Aortic Pulse Wave Velocity and Central Systolic Blood Pressure by Measuring Brachial Cuff Pulse Waveform
    Shiina, Kazuki
    Tomiyama, Hirofumi
    Odaira, Mari
    Yoshida, Masanobu
    Yamashina, Akira
    Kobayashi, Tatsuya
    Fujii, Kenji
    Ogura, Toshihiko
    CIRCULATION, 2011, 124 (21)
  • [30] Is Noninvasive Brachial Systolic Blood Pressure an Accurate Estimate of Central Aortic Systolic Blood Pressure?
    Shih, Yuan-Ta
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chuang, Shao-Yuan
    Hu, Wei-Chih
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (11) : 1283 - 1291