Arterial pressure: agreement between a brachial cuff-based device and radial tonometry

被引:27
|
作者
Park, Chloe M. [1 ,2 ]
Korolkova, Olga [3 ]
Davies, Justin E. [1 ,2 ]
Parker, Kim H. [3 ]
Siggers, Jennifer H. [3 ]
March, Katherine [1 ,2 ]
Tillin, Therese [1 ,2 ]
Chaturvedi, Nish [1 ,2 ]
Hughes, Alun D. [1 ,2 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Int Ctr Circulatory Hlth, London, England
[2] Imperial Coll Healthcare NHS Trust, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London, England
基金
英国惠康基金;
关键词
brachial cuff; invasive; noninvasive; tonometry; central blood pressure; CENTRAL AORTIC PRESSURE; BLOOD-PRESSURE; WAVE-FORM; CARDIOVASCULAR-DISEASE; UPPER-LIMB; METAANALYSIS; CALIBRATION; VALIDATION; IMPACT; MORTALITY;
D O I
10.1097/HJH.0000000000000082
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: Aortic (central) blood pressure (BP) differs from brachial BP and may be a superior predictor of cardiovascular events. However, its measurement is currently restricted to research settings, owing to a moderate level of operator dependency. We tested a new noninvasive device in a large UK cohort. The device estimates central BP using measurements obtained with an upper arm cuff inflated to suprasystolic pressure. We compared these estimates with those obtained using radial tonometry as well as with invasively acquired measurements of aortic BP in a limited number of individuals. Methods: Consecutive cuff-based and tonometry-based estimates of the pressure waveform and the central BP were obtained from 1107 individuals (70 +/- 6 years). Short-term and long-term reproducibility studies were performed on 28 individuals. Simultaneous cuff-based and invasively measured pressure traces were acquired and compared in an additional six individuals (65 +/- 20 years). Results: Central systolic BP, as estimated by the cuff-based device, was found to be highly reproducible (coefficient of variation 4 and 8% for short and long-term reproducibility, respectively) and was comparable to that estimated by tonometry (average difference 3 +/- 6 mmHg, intraclass correlation coefficient = 0.91). The cuff-based pressure waveforms were similar to those acquired invasively (cross-correlation coefficient 0.93), and the difference in the estimated central systolic BP was -5 +/- 8 mmHg (P = 0.2). Conclusion: Cuff-based devices show promise to simplify the measurement of central BP, whilst maintaining a similar fidelity to tonometry. This could lead to improved adoption of estimates of central BP in clinical practice.
引用
收藏
页码:865 / 872
页数:8
相关论文
共 50 条
  • [1] Comparison of Central Blood Pressure Estimated by a Cuff-Based Device With Radial Tonometry
    Peng, Xiaoqing
    Schultz, Martin G.
    Abhayaratna, Walter P.
    Stowasser, Michael
    Sharman, James E.
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (10) : 1173 - 1178
  • [2] Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure
    Bia, Daniel
    Salazar, Federico
    Cinca, Luis
    Gutierrez, Marcos
    Facta, Alvaro
    Diaz, Alejandro
    Zocalo, Yanina
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2024, 44 (03) : 228 - 239
  • [3] Comparison between cuff-based and radial tonometry exercise-induced central blood pressure
    Morales-Acuna, Francisco
    Ratcliffe, Brycen
    Harrison, Caleb
    Crowe, Sierra
    Bockover, Evan
    Pawlak, Robert
    Gurovich, Alvaro N.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (04) : 901 - 911
  • [4] Comparison between cuff-based and radial tonometry exercise-induced central blood pressure
    Francisco Morales-Acuna
    Brycen Ratcliffe
    Caleb Harrison
    Sierra Crowe
    Evan Bockover
    Robert Pawlak
    Alvaro N. Gurovich
    European Journal of Applied Physiology, 2019, 119 : 901 - 911
  • [5] P6.8 Comparison of Central Blood Pressure Estimated by Upper-Arm Cuff-Based Device with Radial Tonometry
    Xiaoqing Peng
    Martin Schultz
    Walter Abhayaratna
    Michael Stowasser
    James Sharman
    Artery Research, 2015, 12 (1) : 26 - 26
  • [6] A Cuff-Based Method for Estimation of Central Blood Pressure in Children: Comparison with Carotid Wall Tracking and Radial Applanation Tonometry
    Milne, Laura Marie
    Watt, Louise
    Guilcher, Antoine
    Sofocleous, Paula
    Chowienczyk, Phil
    Sinha, Manish D.
    PEDIATRIC NEPHROLOGY, 2013, 28 (08) : 1634 - 1634
  • [7] The effect of arterial stiffness on cuff-based blood pressure measurement
    Ma, Yuxiang
    Chen, Ying
    Ma, Yinji
    Feng, Xue
    EXTREME MECHANICS LETTERS, 2021, 48
  • [8] Numerical validation of a suprasystolic brachial cuff-based method for estimating aortic pressure
    Liang, Fuyou
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 1053 - 1062
  • [9] Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure
    Weber, Thomas
    Wassertheurer, Siegfried
    Rammer, Martin
    Maurer, Edwin
    Hametner, Bernhard
    Mayer, Christopher C.
    Kropf, Johannes
    Eber, Bernd
    HYPERTENSION, 2011, 58 (05) : 825 - U317
  • [10] IMPROVED AGREEMENT OF A CUFFLESS 24 HOUR BLOOD PRESSURE MEASUREMENT DEVICE COMPARED TO CUFF-BASED STANDARD MEASUREMENT
    Krisai, P.
    Socrates, T.
    Meienberg, A.
    Mayr, M.
    Vischer, A. S.
    Burkard, T.
    JOURNAL OF HYPERTENSION, 2019, 37 : E129 - E130