Oscillometric and Intra-arterial Blood Pressure in Preterm and Term Infants: Extent of Discrepancy and Factors Associated with Inaccuracy

被引:16
|
作者
Shimokaze, Tomoyuki [1 ]
Akaba, Kazuhiro [1 ]
Saito, Emi [1 ]
机构
[1] Saiseikai Yamagata Hosp, Dept Pediat, Yamagata 9908545, Japan
关键词
noninvasive blood pressure; arterial line; discomfort; sedation; light-for-gestational-age; BIRTH-WEIGHT; ARTERIAL-PRESSURE; AGREEMENT; ACCURACY; MONITOR;
D O I
10.1055/s-0034-1383851
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Securing an arterial line to monitor continuous blood pressure (BP) is difficult in infants. We aimed to reveal the extent of discrepancies between oscillometric and direct BP. Study Design Infants who required continuous BP monitoring were prospectively enrolled. Direct and indirect BP were simultaneously recorded. Disposable BP cuffs matching one-half to two-thirds of the upper arm circumference were used. Results A total of 74 infants were studied (gestational age [GA], 24-42 weeks). The correlation coefficients of systolic, diastolic, and mean arterial BP of indirect and direct measurements were 0.87, 0.82, and 0.84, respectively (p < 0.001). The mean differences in systolic, diastolic, and mean arterial BP (indirect minus direct BP) were 2.2 +/- 5.7, - 6.0 +/- 5.8, and - 1.3 +/- 5.7 mm Hg, respectively. Oscillometric measurements significantly underestimated systolic BP in light-for-gestational-age infants and diastolic BP in infants without fentanyl administration. There were no significant correlations between discrepant BP measurements and edema, vasopressor administration, arterial line location, GA, postnatal age, body weight, pulse rate, or hemoglobin level. In 4.1% of infants, systolic BP increased by 10 to 15 mm Hg at the time of cuff expansion. Conclusion We recommend intra-arterial BP measurement when the BP values seriously influence the therapeutic protocol.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [32] FURTHER OBSERVATIONS ON RETROLENTAL FIBROPLASIA, INCLUDING MEASUREMENTS OF THE INTRA-ARTERIAL BLOOD PRESSURE IN PREMATURE INFANTS
    LAUPUS, WE
    BARNETT, HL
    MCNAMARA, H
    NORTON, EWD
    BOUSQUET, FP
    AMA AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1952, 84 (06): : 749 - 754
  • [33] Accuracy of a wrist blood pressure monitor:: Comparison with intra-arterial pressure
    Sanchez, FJ
    Morillas, P
    Bertomeu, V
    Ruiz, JM
    Frutos, A
    Carrillo, P
    Nuñez, D
    Quiles, J
    Valero, R
    Rodriguez, JA
    JOURNAL OF HYPERTENSION, 2005, 23 : S35 - S35
  • [34] Comparative assessment of the extent of blood pressure by Dinamap versus PulsePen and extent of intra-arterial blood. Study DEPHY: Screening for arterial hypertension in pseudo-diabetes.
    Anceau, C. Cugnet
    Serusclat, A.
    Andre-Fouet, X.
    Finet, G.
    Rioufol, G.
    Gueyffier, F.
    Douek, P.
    Moulin, P.
    DIABETES & METABOLISM, 2010, 36 : A32 - A32
  • [35] Comparison of Non-Invasive Oscillometric and Intra-Arterial Blood Pressure Measurements in Children Admitted to the Pediatric Intensive Care Unit
    Kaur, Jaswinder
    Bhargava, Siddharth
    Pooni, Puneet Aulakh
    Bhat, Deepak
    Dhooria, Gurdeep S.
    Arora, Kamaldeep
    Kakkar, Shruti
    Gill, Karambir
    JOURNAL OF PEDIATRIC INTENSIVE CARE, 2024, 13 (02) : 155 - 161
  • [36] Oscillometric (MEMOPRINT S plus BmedVET) vs. intra-arterial (SIEMENS SIRECUST) blood pressure measurement in anesthetized dogs
    Henke, J
    Pragst, I
    Zahn, P
    Egner, B
    Erhardt, W
    KLEINTIERPRAXIS, 2000, 45 (09): : 661 - +
  • [37] A COMPARISON OF INTRA-ARTERIAL AND AUSCULTATORY BLOOD-PRESSURE READINGS
    CHYUN, DA
    HEART & LUNG, 1985, 14 (03): : 223 - 228
  • [38] Comment on: Z-Z Peng "The agreement between oscillometric and intra-arterial technique for blood pressure monitoring in the lower extremities of infants undergoing aortic coarctation repair'
    Withington, Davinia E.
    PEDIATRIC ANESTHESIA, 2017, 27 (05) : 552 - 552
  • [39] Intra-arterial blood pressure measurement: sources of error and solutions
    Devasahayam, Suresh
    Gangadharan, Naveen
    Surekha, C.
    Baskaran, Bowya
    Mukadam, Farhan Adam
    Subramani, Sathya
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (04) : 1123 - 1138
  • [40] Direct intra-arterial blood-pressure readings in man
    Dameshek, W
    Loman, J
    AMERICAN JOURNAL OF PHYSIOLOGY, 1932, 101 (01): : 140 - 148