Oscillometric (MEMOPRINT S plus BmedVET) vs. intra-arterial (SIEMENS SIRECUST) blood pressure measurement in anesthetized dogs

被引:0
|
作者
Henke, J [1 ]
Pragst, I [1 ]
Zahn, P [1 ]
Egner, B [1 ]
Erhardt, W [1 ]
机构
[1] Tech Univ Munich, Inst Expt Onkol & Therapieforsch, D-81875 Munich, Germany
来源
KLEINTIERPRAXIS | 2000年 / 45卷 / 09期
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
There is a real need for noninvasive blood pressure measurement systems for animals in light of their lower costs and, most importantly, lower risks for the patient. Noninvasive blood pressure measurement systems are much easier to use than their invasive conterparts. The purpose of this experimental study was to compare two techniques for oscillometric (MEMOPRINT) and intra-arterial blood pressure measurement (SIEMENS SIRECUST) in 7 anesthetized dogs with and without conditions pharmacologically affecting the peripheral vascular system.
引用
收藏
页码:661 / +
页数:5
相关论文
共 50 条
  • [1] Comparing Intra-Arterial, Auscultatory, and Oscillometric Measurement Methods for Arterial Blood Pressure
    Babadag, Keziban
    Zaybak, Ayten
    FLORENCE NIGHTINGALE JOURNAL OF NURSING, 2021, 29 (02): : 194 - 202
  • [2] Evaluation of the tongue for oscillometric measurement of arterial pressure in anesthetized Beagle dogs
    Kim, Dalhae
    Kim, Hyunseok
    Shin, Donghwi
    Kim, Jiyoung
    Lee, Inhyung
    Son, Won-gyun
    VETERINARY ANAESTHESIA AND ANALGESIA, 2022, 49 (02) : 149 - 155
  • [3] Compared values of the measurement of average pressure by intra-arterial and oscillometric methods
    Vaquez, H
    Gley, P
    Mouquin, M
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1933, 114 : 1305 - 1307
  • [4] OSCILLOMETRIC AND INTRA-ARTERIAL BLOOD PRESSURE IN CHILDREN POST KIDNEY TRANSPLANTATION: IS INVASIVE BLOOD PRESSURE MEASUREMENT STILL NEEDED?.
    Cornelissen, E.
    Marouane, A.
    Bootsma-Robroeks, C.
    Nusmeier, A.
    PEDIATRIC TRANSPLANTATION, 2017, 21 : 99 - 99
  • [5] Oscillometric and intra-arterial blood pressure in children post-kidney transplantation: Is invasive blood pressure measurement always needed?
    Marouane, Abderrahim
    Cornelissen, Elisabeth A. M.
    Nusmeier, Anneliese
    Bootsma-Robroeks, Charlotte M. H. H. T.
    PEDIATRIC TRANSPLANTATION, 2019, 23 (01)
  • [6] OSCILLOMETRIC AND INTRA-ARTERIAL BLOOD-PRESSURE MEASUREMENTS IN THE NEONATE - A COMPARISON OF METHODS
    LUI, K
    DOYLE, PE
    BUCHANAN, N
    AUSTRALIAN PAEDIATRIC JOURNAL, 1982, 18 (01): : 32 - 34
  • [7] Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke
    Manios, Efstathios
    Vemmosa, Konstantinos
    Tsivgoulis, Georgios
    Barlas, Gerasimos
    Eleni, Koroboki
    Spengos, Konstantinos
    BLOOD PRESSURE MONITORING, 2007, 12 (03) : 149 - 156
  • [8] Is the oscillometric blood pressure measuring device in accord with the intra-arterial invasive blood pressure measuring method?
    Bae, Jang-Whan
    Joo, Hye Jin
    Lee, Won-Yik
    Lee, Sang Yeob
    Lee, Ju-Hee
    Kim, Dong-Woon
    Cho, Myeong-Chan
    Lee, Chung-Suk
    Kim, Eun-Kyong
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 : S20 - S21
  • [9] Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs
    Meurs, KM
    Miller, MW
    Slater, MR
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1996, 32 (06) : 471 - 475
  • [10] Evaluation of the oscillometric method for noninvasive blood pressure measurement during cuff deflation and cuff inflation with reference to intra-arterial blood pressure
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Argha, Ahmadreza
    Rehan, Rajan
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42 (07) : 1235 - 1247