Oscillometric and Intra-arterial Blood Pressure in Preterm and Term Infants: Extent of Discrepancy and Factors Associated with Inaccuracy

被引:15
|
作者
Shimokaze, Tomoyuki [1 ]
Akaba, Kazuhiro [1 ]
Saito, Emi [1 ]
机构
[1] Saiseikai Yamagata Hosp, Dept Pediat, Yamagata 9908545, Japan
关键词
noninvasive blood pressure; arterial line; discomfort; sedation; light-for-gestational-age; BIRTH-WEIGHT; ARTERIAL-PRESSURE; AGREEMENT; ACCURACY; MONITOR;
D O I
10.1055/s-0034-1383851
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Securing an arterial line to monitor continuous blood pressure (BP) is difficult in infants. We aimed to reveal the extent of discrepancies between oscillometric and direct BP. Study Design Infants who required continuous BP monitoring were prospectively enrolled. Direct and indirect BP were simultaneously recorded. Disposable BP cuffs matching one-half to two-thirds of the upper arm circumference were used. Results A total of 74 infants were studied (gestational age [GA], 24-42 weeks). The correlation coefficients of systolic, diastolic, and mean arterial BP of indirect and direct measurements were 0.87, 0.82, and 0.84, respectively (p < 0.001). The mean differences in systolic, diastolic, and mean arterial BP (indirect minus direct BP) were 2.2 +/- 5.7, - 6.0 +/- 5.8, and - 1.3 +/- 5.7 mm Hg, respectively. Oscillometric measurements significantly underestimated systolic BP in light-for-gestational-age infants and diastolic BP in infants without fentanyl administration. There were no significant correlations between discrepant BP measurements and edema, vasopressor administration, arterial line location, GA, postnatal age, body weight, pulse rate, or hemoglobin level. In 4.1% of infants, systolic BP increased by 10 to 15 mm Hg at the time of cuff expansion. Conclusion We recommend intra-arterial BP measurement when the BP values seriously influence the therapeutic protocol.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [21] Evaluation of the oscillometric method for noninvasive blood pressure measurement during cuff deflation and cuff inflation with reference to intra-arterial blood pressure
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Argha, Ahmadreza
    Rehan, Rajan
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42 (07) : 1235 - 1247
  • [22] Agreement between noninvasive oscillometric and invasive intra-arterial blood pressure in children with ruptured brain arteriovenous malformations
    Chang, Nathan
    Poon, Diana
    Casazza, May
    Medrano, Amanda
    Basnett, Kaitlyn
    Koilparampil, Lesley
    Rasmussen, Lindsey
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2024, 243
  • [23] Blood Pressure Measurement Compared Between Oscillometric Blood Pressure Monitoring and Gold Standard Intra-Arterial Blood Pressure Monitoring in Adult Shock Resuscitation Patients
    Tongyoo, Surat
    Visuthisakchai, Suharit
    Permpikul, Chairat
    JOURNAL OF CRITICAL & INTENSIVE CARE, 2022, 13 (03): : 102 - 109
  • [24] The effect of oscillometric blood pressure measurement on pain response in preterm infants
    Kavurt, Sumru
    Arslan, Zehra
    Unal, Sezin
    Bas, Ahmet Yagmur
    Demirel, Nihal
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2023, 59 (11) : 1251 - 1255
  • [25] Validation of oscillometric ratio and maximum gradient methods for non-invasive blood pressure measurement with intra-arterial blood pressure measurements as reference
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Argha, Ahmadreza
    Rehan, Rajan
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42 (06) : 1075 - 1085
  • [26] AMBULATORY MONITORING OF INTRA-ARTERIAL BLOOD-PRESSURE
    MELVILLE, D
    BIOLOGICAL PSYCHOLOGY, 1985, 20 (03) : 227 - 227
  • [27] INTRA-ARTERIAL BLOOD PRESSURE IN PATIENTS WITH COARCTATION OF THE AORTA
    BROWN, GE
    POLLACK, AA
    CLAGETT, OT
    WOOD, EH
    PROCEEDINGS OF THE STAFF MEETINGS OF THE MAYO CLINIC, 1948, 23 (06): : 129 - 134
  • [28] ERRORS IN INTRA-ARTERIAL BLOOD-PRESSURE MEASUREMENTS
    ZINGG, W
    BAINES, WD
    MATHUR, AN
    CANADIAN JOURNAL OF SURGERY, 1968, 11 (01) : 93 - &
  • [29] P113 The Forgotten Black Box of Blood Pressure: Error in Oscillometric Mean Arterial Pressure is Associated with Cuff Measurement Inaccuracy
    Dean Picone
    Martin Schultz
    Matthew Armstrong
    Nathan Dwyer
    Philip Roberts-Thomson
    Thomas Weber
    James Sharman
    Artery Research, 2019, 25 (Suppl 1) : S153 - S153
  • [30] Comparison of non-invasive oscillometric and intra-arterial 24-hour blood pressure measurement in acute stroke
    Manios, E
    Tsivgoulis, G
    Spengos, K
    Spiliopoulou, J
    Dolianitis, K
    Tseke, P
    Xynos, K
    Dimitriou, A
    Vemmos, K
    Zakopoulos, N
    Mavrikakis, M
    JOURNAL OF HYPERTENSION, 2005, 23 : S124 - S124