Multielemental determination in oil matrices diluted in xylene by ICP-MS with a dynamic reaction cell employing methane as reaction gas for solving specific interferences

被引:23
|
作者
de Souza, Jefferson R. [1 ]
Duyck, Christiane B. [1 ,2 ]
Fonseca, Teresa C. O.
Saint'Pierre, Tatiana D. [1 ]
机构
[1] Pontificia Univ Catolica Rio de Janeiro PUC Rio, Dept Quim, BR-22451900 Rio De Janeiro, Brazil
[2] Univ Fed Fluminense, Dept Quim, BR-24020150 Niteroi, RJ, Brazil
关键词
PLASMA-MASS SPECTROMETRY; OPTICAL-EMISSION SPECTROMETRY; ATOMIC SPECTROMETRY; SAMPLE INTRODUCTION; LUBRICATING OILS; TRACE-ELEMENTS; CRUDE-OIL; BIODIESEL; COLLISION; FRACTIONS;
D O I
10.1039/c2ja30085k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analysis of organic samples by ICP-MS is still a challenge due to the occurrence of non-spectral and spectral interferences, which usually requires time-consuming sample preparation procedures for their minimization. In this work, results are presented on the direct multielemental determination in oil samples after simple dilution in xylene. The solutions were introduced into the plasma by a sample introduction system especially suited for organics, and the operational conditions of the plasma and the dynamic reaction cell were optimized. A central composite design showed that the nebulizer and the auxiliary gas flow rates had a significant influence on interference formation, monitored by Ba++ and LaO+ intensities. The compromised plasma conditions were: RF power of 1300 W and gas flow rates of 0.42 L min(-1) for the nebulizer (Ar), 1.1 L min(-1) for the auxiliary gas (Ar), and 0.1 L min(-1) of O-2 used as an additional gas. In order to minimize spectral interferences on Ca, Cr, Fe and Mg, the operational conditions of the dynamic reaction cell, working with methane as reaction gas, were optimized for Fe-56, Cr-52, Ca-40 and Mg-24. Two certified reference materials, NIST 1634c (used fuel oil) and NIST 1085b (lubricating oil), were analyzed and the recoveries were in the range of 90% to 110% for most elements, being the sample detection limits between 0.2 mu g kg(-1) (Cr) and 40 mu g kg(-1) (Zn). Reliability of the data was also tested by comparing the results for a set of biodiesel samples with those determined by ICP OES and good agreement was obtained for most elements. Differences in the elemental compositions of biodiesel samples produced from different raw materials were observed, suggesting that elemental fingerprinting may be used for source identification.
引用
收藏
页码:1280 / 1286
页数:7
相关论文
共 50 条
  • [41] Rapid and accurate determination of chlorine isotopic ratios with ICP-MS/MS using O2 reaction gas
    Schlieder, Tyler D.
    Rocco, Nicole D.
    di Vacri, Maria Laura
    Arnquist, Isaac J.
    Bottenus, Danny
    Huber, Zachary
    Mcnamara, Bruce
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (10) : 2502 - 2507
  • [42] A dynamic reaction cell (DRC) solution to oxide-based interferences in inductively coupled plasma mass spectrometry (ICP-MS) analysis of the noble metals
    Simpson, LA
    Thomsen, M
    Alloway, BJ
    Parker, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) : 1375 - 1380
  • [43] Application of neon as a collision gas - a cell gas index for collision/reaction cell-ICP-MS determination
    Narukawa, T.
    Shikino, O.
    Chiba, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (10) : 2142 - 2147
  • [44] Achieving high trace-metal purity levels using dynamic reaction cell ICP-MS
    Ping, CM
    Kishi, Y
    Kawabata, K
    Thomas, R
    MICRO, 2003, 21 (03): : 37 - 42
  • [45] Using dynamic reaction cell ICP-MS technology to determine the full suite of elements in rainwater samples
    Gürleyük, H
    Brunette, RC
    Howard, CR
    Schneider, C
    Thomas, R
    SPECTROSCOPY, 2005, 20 (01) : 24 - +
  • [46] Determination of aluminum in large volume parenteral drug products used in total parenteral nutrition therapy by ICP-MS with a dynamic reaction cell
    Harigaya, Koki
    Kuwahara, Yukari
    Nishi, Hiroyuki
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (04) : 475 - 479
  • [47] Analysis of diluted sea-water at the ng L-1 level using an ICP-MS with an octopole reaction cell
    Leonhard, P
    Pepelnik, R
    Prange, A
    Yamada, N
    Yamada, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) : 189 - 196
  • [48] Validation of a digestion procedure for ICP-AES and dynamic reaction cell ICP-MS for trace elemental analysis in environmental samples
    X. J. Yang
    G. K.-C. Low
    Environmental Chemistry Letters, 2009, 7 : 381 - 387
  • [49] Validation of a digestion procedure for ICP-AES and dynamic reaction cell ICP-MS for trace elemental analysis in environmental samples
    Yang, X. J.
    Low, G. K. -C.
    ENVIRONMENTAL CHEMISTRY LETTERS, 2009, 7 (04) : 381 - 387
  • [50] Comparison of high-resolution and dynamic reaction cell ICP-MS capabilities for forensic analysis of iron in glass
    Castro, Waleska
    Trejos, Tatiana
    Naes, Benjamin
    Almirall, Jose R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (04) : 663 - 672