Analysis of diluted sea-water at the ng L-1 level using an ICP-MS with an octopole reaction cell

被引:125
|
作者
Leonhard, P
Pepelnik, R
Prange, A [1 ]
Yamada, N
Yamada, T
机构
[1] GKSS Forschungszentrum Geesthacht GmbH, Inst Coastal Res Phys & Chem Anal, Geesthacht, Germany
[2] Agilent Technol, Tokyo, Japan
关键词
D O I
10.1039/b110180n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ICP-MS with an octopole reaction/collision cell was used for the multi-element determination of trace elements in sea-water. The use of a reaction or collision gas, respectively, reduces serious spectral interferences from matrix elements such as ArCl+ or ArNa+. On introducing He or H-2 to the cell, detection limits of 0.3 ng L-1 for U to 20 ng L-1 for Fe and As were determined in 10-fold diluted sea-water. The trace elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Mo, Cd, Pb and U were determined in diluted sea-water samples (certified reference material: NASS-5, SLEW-3) with a trueness of +/- 20% to the certified values. For most of the elements an accuracy of better than 19% was achieved with no sample pre-treatment other than simple dilution.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [1] Multielement analysis of human seminal plasma by octopole reaction cell ICP-MS
    20144300126370
    Živković, Tanja, 1600, Royal Society of Chemistry (29):
  • [2] Multielement analysis of human seminal plasma by octopole reaction cell ICP-MS
    Zivkovic, Tanja
    Tariba, Blanka
    Pizent, Alica
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (11) : 2114 - 2126
  • [3] Determination of selenium in milk powder by octopole reaction cell ICP-MS
    Cho, Sung-Eel
    Kim, Mi-Ju
    Kim, Yong-Ha
    Min, Young-Keun
    Kim, Young-Sang
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (03): : 203 - 210
  • [4] Routine analysis of ultra pure water by ICP-MS in the low- and sub-ng/L level
    Hoelzl, R
    Fabry, L
    Kotz, L
    Pahlke, S
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (01): : 64 - 69
  • [5] Routine analysis of ultra pure water by ICP-MS in the low- and sub-ng/L level
    R. Hoelzl
    L. Fabry
    L. Kotz
    S. Pahlke
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 64 - 69
  • [6] The use of a dual mode sample introduction system for internal standardization in the determination of Hg at the ng L-1 level by cold vapor ICP-MS
    Pyhtila, Heidi
    Niemela, Matti
    Peramaki, Paavo
    Piispanen, Juha
    Ukonmaanaho, Liisa
    ANALYTICAL METHODS, 2013, 5 (12) : 3082 - 3088
  • [7] Effects of deuterium in octopole reaction and collision cell ICP-MS on detection of selenium in extracellular fluids
    Ogra, Y
    Ishiwata, K
    Suzuki, KT
    ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) : 123 - 129
  • [8] Accurate, Low-Level Sulfur Analysis by ICP-MS Using MS/MS with Oxygen Reaction Cell Gas
    McCurdy, Ed
    Woods, Glenn
    Georg, Bastian
    Sugiyama, Naoki
    SPECTROSCOPY, 2020, 35 : 27 - 34
  • [9] Strategy for water analysis using ICP-MS
    Fernández-Turiel, JL
    Llorens, JF
    López-Vera, F
    Gómez-Artola, C
    Morell, I
    Gimeno, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (06): : 601 - 606
  • [10] Strategy for water analysis using ICP-MS
    J. L. Fernández-Turiel
    J. F. Llorens
    F. López-Vera
    C. Gómez-Artola
    I. Morell
    D. Gimeno
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 601 - 606