Measurement device for detecting oxygen saturation in blood, heart rate, and temperature of human body

被引:8
|
作者
Suprayitno, E. A. [1 ]
Marlianto, M. R. [1 ]
Mauliana, M., I [2 ]
机构
[1] Univ Muhammadiyah Sidoarjo, Elect Engn Dept, Gelam 250, Sidoarjo, Indonesia
[2] Univ Muhammadiyah Sidoarjo, Informat Engn Dept, Gelam 250, Sidoarjo, Indonesia
关键词
D O I
10.1088/1742-6596/1402/3/033110
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The progress of science and technology must be able to help resolve human medical problems for human survival. In this study, integrated measurement of oxygen saturation in the blood, heart rate and temperature of the human body have been made into one tool whose measurement results are displayed directly on the LCD display on a measuring instrument and an Android Smartphone. This tool uses Arduino Nano as its Microcontroller, Bluetooth as wireless serial communication with Android smartphone, Android Application Made with MIT App Inventor, MAX30100 sensor is used to measure blood oxygen saturation and heart rate, and MLX90614 sensor to measure body temperature. Testing Measurements that have been made are calibrated with Industrial standard measuring instruments (Oximeters) and digital thermometers. The result is that the accuracy of the tool reaches 99.62% for blood oxygen saturation measurements, 97.55% for heart rate, and 99.62% for body temperature when compared with industry standard devices. Android applications have been successfully installed on 5 types of smartphones with different brands and specifications. The Bluetooth range of a measuring device for a smartphone in maximum data transfer is 29 meters without a hitch and a maximum of 21.5 meters with obstacles.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Low-Cost and Portable Device to Monitor Heart Rate, Blood Oxygen Saturation and Body Temperature with Warning System
    Guo, Cong
    Ma, Qianhui
    Shen, Mingyu
    Dong, Xinghao
    Chen, Shuaifei
    Liu, Fulong
    PROCEEDINGS OF TEPEN 2022, 2023, 129 : 641 - 652
  • [2] Detecting Four-Limb Blood Oxygen Saturation and Heart Rate based on Reflex Photoplethysmography
    Lu, Chi-Heng
    Wei, Jhao-En
    Tuan, Chiu-Ching
    2018 2ND INTERNATIONAL CONFERENCE ON E-SOCIETY, E-EDUCATION AND E-TECHNOLOGY (ICSET 2018), 2018, : 145 - 149
  • [3] Realization and Evaluation of the Device for Measuring the Impedance of Human Body for Detecting the Respiratory and Heart Rate
    Metshein, Margus
    Parve, Toomas
    Annus, Paul
    Rist, Marek
    Min, Mart
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2017, 23 (03) : 36 - 42
  • [4] EFFECTS OF BODY POSITION ON OXYGEN SATURATION, TEMPERATURE, RESPIRATORY RATE, AND HEART RATE OF HEALTHY TERM AND PRETERM INFANTS
    Alsufayan, F.
    Saker, A.
    Mahwi, S.
    Shawkat, S.
    PEDIATRIC RESEARCH, 2010, 68 : 565 - 565
  • [5] System design for wearable blood oxygen saturation and pulse measurement device
    Fu, Yu
    Liu, Jian
    6TH INTERNATIONAL CONFERENCE ON APPLIED HUMAN FACTORS AND ERGONOMICS (AHFE 2015) AND THE AFFILIATED CONFERENCES, AHFE 2015, 2015, 3 : 1187 - 1194
  • [6] Monitoring of heart rate, blood oxygen saturation, and blood pressure using a smartphone
    Nemcova, Andrea
    Jordanova, Ivana
    Varecka, Martin
    Smisek, Radovan
    Marsanova, Lucie
    Smital, Lukas
    Vitek, Martin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 59
  • [7] Human Body Resistance and Temperature Measurement Device
    Wara, S. T.
    Oghogho, I
    Abayomi-Alli, A.
    Odikayor, C. D.
    Essien, M. S.
    ADVANCES IN MATERIALS AND SYSTEMS TECHNOLOGIES II, 2009, 62-64 : 153 - 158
  • [8] The Comparison of Effect of Two Different Bathing Methods on Heart Rate, Oxygen Saturation and Body Temperature of Newborns
    Ar, I.
    Gozen, D.
    EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1839 - 1840
  • [9] 1140 Effects of Body Position on Oxygen Saturation, Temperature, Respiratory Rate, and Heart Rate of Healthy Term and Preterm Infants
    F Alsufayan
    A Saker
    S Mahwi
    S Shawkat
    Pediatric Research, 2010, 68 : 565 - 565
  • [10] Modeling of the blood oxygen and heart rate measurement system
    Lyashenyk, A., V
    Nykyrui, R. I.
    Goyanyuk, I. V.
    PHYSICS AND CHEMISTRY OF SOLID STATE, 2024, 25 (01): : 104 - 108