Measurement device for detecting oxygen saturation in blood, heart rate, and temperature of human body

被引:8
|
作者
Suprayitno, E. A. [1 ]
Marlianto, M. R. [1 ]
Mauliana, M., I [2 ]
机构
[1] Univ Muhammadiyah Sidoarjo, Elect Engn Dept, Gelam 250, Sidoarjo, Indonesia
[2] Univ Muhammadiyah Sidoarjo, Informat Engn Dept, Gelam 250, Sidoarjo, Indonesia
关键词
D O I
10.1088/1742-6596/1402/3/033110
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The progress of science and technology must be able to help resolve human medical problems for human survival. In this study, integrated measurement of oxygen saturation in the blood, heart rate and temperature of the human body have been made into one tool whose measurement results are displayed directly on the LCD display on a measuring instrument and an Android Smartphone. This tool uses Arduino Nano as its Microcontroller, Bluetooth as wireless serial communication with Android smartphone, Android Application Made with MIT App Inventor, MAX30100 sensor is used to measure blood oxygen saturation and heart rate, and MLX90614 sensor to measure body temperature. Testing Measurements that have been made are calibrated with Industrial standard measuring instruments (Oximeters) and digital thermometers. The result is that the accuracy of the tool reaches 99.62% for blood oxygen saturation measurements, 97.55% for heart rate, and 99.62% for body temperature when compared with industry standard devices. Android applications have been successfully installed on 5 types of smartphones with different brands and specifications. The Bluetooth range of a measuring device for a smartphone in maximum data transfer is 29 meters without a hitch and a maximum of 21.5 meters with obstacles.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] OXYGEN SATURATION AND HEART RATE DURING EXERCISE PERFORMANCE
    Lain, David
    Granger, Wesley
    ANESTHESIA AND ANALGESIA, 2013, 117 : 36 - 37
  • [42] Heart rate and oxygen saturation correlates of infant apnea
    Carbone T.
    Marrero L.C.
    Weiss J.
    Hiatt M.
    Hegyi T.
    Journal of Perinatology, 1999, 19 (1) : 44 - 47
  • [43] A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations
    Longmore, Sally K.
    Lui, Gough Y.
    Naik, Ganesh
    Breen, Paul P.
    Jalaludin, Bin
    Gargiulo, Gaetano D.
    SENSORS, 2019, 19 (08):
  • [44] One hour effects of salbutamol and formoterol on blood pressure, heart rate and oxygen saturation in asthmatics
    Capuchinho-Junior, Geraldo Andrade
    Dias, Ricardo Marques
    da Silva de Carvalho, Sonia Regina
    REVISTA PORTUGUESA DE PNEUMOLOGIA, 2008, 14 (03) : 353 - 361
  • [45] The Evaluation of Blood Flow Velocity and Heart Rate by the Frequency of Oxygen Saturation Fluctuation in Skin Tissue
    Tsai, Hsin-Yi
    Huang, Kuo-Cheng
    Hung, Min-Wei
    Yang, Ching-Ching
    Hsiao, Wen-Tse
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 1291 - 1294
  • [46] The heart rate, blood lactate and oxygen saturation changes of female futsal players during competition
    Egesoy, Halit
    Oksuzoglu, Aysegul Yapici
    Gumusdag, Hayrettin
    Atabas, Engin Gunes
    Celik, Eylem
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (04): : 1386 - 1389
  • [47] Axillary temperature measurement is not better tolerated than rectal in premature infants.: Influence of axillary and rectal temperature measurement on heart rate, oxygen saturation and cerebral haemodynamics and oxygenation
    Roll, C
    Horsch, S
    Hüsing, J
    Hanssler, L
    ZEITSCHRIFT FUR GEBURTSHILFE UND NEONATOLOGIE, 2000, 204 (05): : 193 - 197
  • [48] Heart rate measurement based on fluttering signal from human body
    Jin, Jing-Jing
    Wang, Xu
    Yang, Dan
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2009, 30 (02): : 176 - 179
  • [49] MIXED VENOUS TEMPERATURE, PH, AND OXYGEN-SATURATION AND HEART-RATE DURING EXERCISE
    MCELROY, PA
    WEBER, KT
    JANICKI, JS
    NAPPHOLZ, TA
    CIRCULATION, 1985, 72 (04) : 432 - 432
  • [50] EFFECTS OF TEMPERATURE AND BODY SIZE UPON HEART RATE AND OXYGEN CONSUMPTION IN TURTLES
    HUTTON, KE
    BOYER, DR
    WILLIAMS, JC
    CAMPBELL, PM
    JOURNAL OF CELLULAR AND COMPARATIVE PHYSIOLOGY, 1960, 55 (01): : 87 - 93