Measurement device for detecting oxygen saturation in blood, heart rate, and temperature of human body

被引:8
|
作者
Suprayitno, E. A. [1 ]
Marlianto, M. R. [1 ]
Mauliana, M., I [2 ]
机构
[1] Univ Muhammadiyah Sidoarjo, Elect Engn Dept, Gelam 250, Sidoarjo, Indonesia
[2] Univ Muhammadiyah Sidoarjo, Informat Engn Dept, Gelam 250, Sidoarjo, Indonesia
关键词
D O I
10.1088/1742-6596/1402/3/033110
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The progress of science and technology must be able to help resolve human medical problems for human survival. In this study, integrated measurement of oxygen saturation in the blood, heart rate and temperature of the human body have been made into one tool whose measurement results are displayed directly on the LCD display on a measuring instrument and an Android Smartphone. This tool uses Arduino Nano as its Microcontroller, Bluetooth as wireless serial communication with Android smartphone, Android Application Made with MIT App Inventor, MAX30100 sensor is used to measure blood oxygen saturation and heart rate, and MLX90614 sensor to measure body temperature. Testing Measurements that have been made are calibrated with Industrial standard measuring instruments (Oximeters) and digital thermometers. The result is that the accuracy of the tool reaches 99.62% for blood oxygen saturation measurements, 97.55% for heart rate, and 99.62% for body temperature when compared with industry standard devices. Android applications have been successfully installed on 5 types of smartphones with different brands and specifications. The Bluetooth range of a measuring device for a smartphone in maximum data transfer is 29 meters without a hitch and a maximum of 21.5 meters with obstacles.
引用
收藏
页数:6
相关论文
共 50 条
  • [32] DESIGN A WEARABLE DEVICE FOR BLOOD OXYGEN CONCENTRATION AND TEMPORAL HEART BEAT RATE
    Myint, Cho Zin
    Barsoum, Nader
    Ing, Wong Kiing
    POWER CONTROL AND OPTIMIZATION, 2010, 1239 : 213 - 219
  • [33] Changes in blood oxygen saturation and heart rate of young male and female subjects due to flow rate of highly concentrated oxygen
    Jun, Jae-Hoon
    Choi, Mi-Hyun
    Lee, Su-Jeong
    Yang, Jae-Woong
    Kim, Ji-Hye
    Choi, Jin-Seung
    Park, Jang-Yeon
    Tack, Gye-Rae
    Lee, Beob-Yi
    Kim, Hyun-Jun
    Chung, Soon-Cheol
    HEALTHMED, 2010, 4 (04): : 1062 - 1067
  • [34] Wireless Body Area Network For Monitoring Body Temperature, Heart Beat And Oxygen In Blood
    Al Rasyid, M. Udin Harun
    Lee, Bih-Hwang
    Sudarsono, Amang
    2015 INTERNATIONAL SEMINAR ON INTELLIGENT TECHNOLOGY AND ITS APPLICATIONS (ISITIA), 2015, : 95 - 98
  • [35] Development of Sleep Apnea Device by detection of blood pressure and heart rate measurement
    Sharma, Smita
    Mishra, V. M.
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2021, 12 (01) : 145 - 153
  • [36] Development of Sleep Apnea Device by detection of blood pressure and heart rate measurement
    Smita Sharma
    V. M. Mishra
    International Journal of System Assurance Engineering and Management, 2021, 12 : 145 - 153
  • [37] Two channel dynamic optical phantom for transabdominal and fetal oxygen saturation with heart rate measurement
    Yahya, M. A. M.
    Gan, K. B.
    Sameen, Aws Zuhair
    2017 INTERNATIONAL CONFERENCE ON ROBOTICS, AUTOMATION AND SCIENCES (ICORAS), 2017,
  • [38] Reflectance Pulse Oximetry (RPO): A New Tool for Continous Measurement of Heart Rate and Oxygen Saturation
    Arthur I Eidelman
    Yisrael Saroussi
    Iftach Y Shemesh
    Pediatric Research, 1999, 45 : 16 - 16
  • [39] Reflectance pulse oximetry (RPO): A new tool for continous measurement of heart rate and oxygen saturation
    Eidelman, AI
    Saroussi, Y
    Shemesh, IY
    PEDIATRIC RESEARCH, 1999, 45 (05) : 16A - 16A
  • [40] The effects of positional restraint on heart rate and oxygen saturation
    Schmidt, P
    Snowden, T
    JOURNAL OF EMERGENCY MEDICINE, 1999, 17 (05): : 777 - 782