Detecting Four-Limb Blood Oxygen Saturation and Heart Rate based on Reflex Photoplethysmography

被引:1
|
作者
Lu, Chi-Heng [1 ]
Wei, Jhao-En [1 ]
Tuan, Chiu-Ching [1 ]
机构
[1] Natl Taipei Univ Technol, Grad Inst Elect Engn, 1,Sec 3,Zhongxiao E Rd, Taipei 10608, Taiwan
关键词
Photoplethysmography; Four-Limb; Oxygen Saturation; Heart Rate; Hyperbaric Oxygen Therapy; Vascular suture; NEAR-INFRARED SPECTROSCOPY;
D O I
10.1145/3268808.3268822
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The study purpose is to construct a reflective Oxygen Saturation (SpO(2)) and Heart Rate (HR) four-limb detective device, improve transmission SpO(2) device only to measure finger, toe and earlobe. Using Silicon Labs Si1143, Arduino Nano, self-calibrated SpO(2) algorithm and mobile application software constitute a mobile reflective SpO(2) and HR detective device. Static four parts and post-exercise experiment had been carried out to test our device, the result can achieve comparable performance to a clinical device with no significant difference revealed by paired t-tests. This study has applied for clinical trial permission, the schedule will improve the calibration curve and compensation factor of unverifiable body parts by blood draw comparison. Provide clinical staff for immediate local SpO(2) and HR information, evaluate the effectiveness of vascular suture and hyperbaric oxygen therapy.
引用
收藏
页码:145 / 149
页数:5
相关论文
共 50 条
  • [1] Accurate Detection of Heart Rate and Blood Oxygen Saturation in Reflective Photoplethysmography
    Krizea, Maria
    Gialelis, John
    Kladas, Anastasios
    Theodorou, Gerasimos
    Protopsaltis, Grigoris
    Koubias, Stavros
    2020 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT 2020), 2020,
  • [2] Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
    Shelley, Kirk H.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S31 - S36
  • [3] A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations
    Longmore, Sally K.
    Lui, Gough Y.
    Naik, Ganesh
    Breen, Paul P.
    Jalaludin, Bin
    Gargiulo, Gaetano D.
    SENSORS, 2019, 19 (08):
  • [4] Measurement device for detecting oxygen saturation in blood, heart rate, and temperature of human body
    Suprayitno, E. A.
    Marlianto, M. R.
    Mauliana, M., I
    4TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE, 2019, 2019, 1402
  • [5] Effect of practice on four-limb co-ordination with and without inter-limb reflex
    Inui, N
    JOURNAL OF HUMAN MOVEMENT STUDIES, 2002, 42 (06): : 481 - 493
  • [6] Four-Limb Blood Pressure as Predictors of Mortality in Elderly Chinese
    Sheng, Chang-Sheng
    Liu, Ming
    Zeng, Wei-Fang
    Huang, Qi-Fang
    Li, Yan
    Wang, Ji-Guang
    HYPERTENSION, 2013, 61 (06) : 1155 - +
  • [7] CHARACTERISTICS OF FOUR-LIMB BLOOD PRESSURE IN TAKAYASU'S ARTERITIS
    Chen, Yang
    Dong, Hui
    Wang, Kai-hao
    Che, Wu-qiang
    Xiong, Hong-liang
    Zou, Yu-bao
    Jiang, Xiong-jing
    JOURNAL OF HYPERTENSION, 2018, 36 : E193 - E193
  • [8] Monitoring of heart rate, blood oxygen saturation, and blood pressure using a smartphone
    Nemcova, Andrea
    Jordanova, Ivana
    Varecka, Martin
    Smisek, Radovan
    Marsanova, Lucie
    Smital, Lukas
    Vitek, Martin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 59
  • [9] Four-Limb Blood Pressure Measurement A Research Tool Looking for Clinical Use
    Clark, Christopher E.
    HYPERTENSION, 2013, 61 (06) : 1146 - 1147
  • [10] Isolated subclavian artery: an echocardiographic diagnosis and explanation of unusual four-limb blood pressures
    Larios, Guillermo
    Almeida, Claudia L.
    Ramroop, Ronand M.
    Dragulescu, Andreea
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (01) : 117 - 117