A disc-based quantitative carrier test method to assess the virucidal activity of chemical germicides

被引:68
|
作者
Sattar, SA [1 ]
Springthorpe, VS [1 ]
Adegbunrin, O [1 ]
Abu Zafer, A [1 ]
Busa, M [1 ]
机构
[1] Univ Ottawa, Ctr Res Environm Microbiol, Ottawa, ON K1H 8M5, Canada
关键词
virucides; carrier test; germicides; metal discs; non-enveloped viruses; infection control;
D O I
10.1016/S0166-0934(03)00192-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Suspension tests for virucidal activity of chemical germicides are easier to perform, but they normally do not present the test product with a strong enough challenge. In contrast, carrier tests, where the test virus is dried on an animate or inanimate surface, offer the test formulation a higher level of challenge because it first has to penetrate successfully the inoculum to gain access to and inactivate the target organism on the carrier. Since pathogens in nature are normally found adsorbed to surfaces and/or embedded in organic or cellular debris, the results of carrier tests are more relevant to predicting the activity of chemical germicides under field situations. The method described below uses discs (1 cm in diameter) of brushed stainless steel discs as carriers. Ten mul of the test virus in a soil load is placed on each disc and the inoculum dried under ambient conditions. The dried inoculum is then exposed to 50 mul of the test formulation or a control solution for a defined contact time at the specified temperature. EBSS (0.95 ml) is added to each carrier holder to dilute/neutralize the germicide, the inoculum eluted and the eluates titrated in cell cultures to determine the degree of loss in virus viability. At least five test and three control carriers are used in each test. Controls are also included to test for toxicity of the test formulation to the host cells and any interference sub-cytotoxic levels of the formulation may have on the ability of the virus to infect the cells. The method has been used with several types of human and animal pathogenic viruses to test the activity of all major classes of chemical germicides against them. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [31] A quantitative method to assess extrasynaptic NMDA receptor function in the protective effect of synaptic activity against neurotoxicity
    C Peter Bengtson
    Oliver Dick
    Hilmar Bading
    BMC Neuroscience, 9
  • [32] A quantitative method to assess extrasynaptic NMDA receptor function in the protective effect of synaptic activity against neurotoxicity
    Bengtson, C. Peter
    Dick, Oliver
    Bading, Hilmar
    BMC NEUROSCIENCE, 2008, 9 (1)
  • [33] To reduce cytotoxicity when testing the virucidal activity of chemical disinfectants and biocides: The "T-25 method" as an alternative to "large-volume-plating"
    Rheinbaben, F. V.
    Kohnlein, J.
    Schmidt, N.
    Hildebrandt, C.
    Werner, S.
    HELIYON, 2023, 9 (10)
  • [34] A new analytical method for impact splitting strain rate in Brazilian disc test based on SHPB
    Yue, Chengjun
    Chen, Li
    Yuan, Jiayi
    Li, Qiyao
    Xu, Linfeng
    MATERIALS AND STRUCTURES, 2023, 56 (04)
  • [35] A new analytical method for impact splitting strain rate in Brazilian disc test based on SHPB
    Chengjun Yue
    Li Chen
    Jiayi Yuan
    Qiyao Li
    Linfeng Xu
    Materials and Structures, 2023, 56
  • [36] 13C mixed triglyceride breath test:: A noninvasive method to assess lipase activity in children
    van Dijk-van Aalst, K
    Van Den Driessche, M
    van der Schoor, S
    Schiffelers, S
    van't Westeinde, T
    Ghoos, Y
    Veereman-Wauters, G
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2001, 32 (05): : 579 - 585
  • [37] A rapid quantitative detection method of colorimetric test strip based on machine vision
    Ding, Youchun
    Wang, Qiaohua
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2011, 9 (3-4): : 836 - 839
  • [38] Fast Quantitative Parallax Test Based on Sine-Like Micrometric Method
    Niu Jin
    Xu Xiping
    Wang Shu
    An Zhiyong
    ACTA OPTICA SINICA, 2018, 38 (04)
  • [39] A Quantitative Evaluation Method of Pilot Errors during Landing Process of Carrier-Based Aircraft
    Sun, Guoqiang
    Zeng, Shengkui
    Guo, Jianbin
    Zhou, Guo
    PROCEEDINGS OF THE 2015 FIRST INTERNATIONAL CONFERENCE ON RELIABILITY SYSTEMS ENGINEERING 2015 ICRSE, 2015,
  • [40] Quantitative Analysis of EEG Slow Wave Activity Based on MinPeakProminence Method
    Yildirim, Sema
    Kocer, Hasan Erdinc
    Ekmekci, Ahmet Hakan
    TRAITEMENT DU SIGNAL, 2021, 38 (03) : 757 - 773