A disc-based quantitative carrier test method to assess the virucidal activity of chemical germicides

被引:68
|
作者
Sattar, SA [1 ]
Springthorpe, VS [1 ]
Adegbunrin, O [1 ]
Abu Zafer, A [1 ]
Busa, M [1 ]
机构
[1] Univ Ottawa, Ctr Res Environm Microbiol, Ottawa, ON K1H 8M5, Canada
关键词
virucides; carrier test; germicides; metal discs; non-enveloped viruses; infection control;
D O I
10.1016/S0166-0934(03)00192-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Suspension tests for virucidal activity of chemical germicides are easier to perform, but they normally do not present the test product with a strong enough challenge. In contrast, carrier tests, where the test virus is dried on an animate or inanimate surface, offer the test formulation a higher level of challenge because it first has to penetrate successfully the inoculum to gain access to and inactivate the target organism on the carrier. Since pathogens in nature are normally found adsorbed to surfaces and/or embedded in organic or cellular debris, the results of carrier tests are more relevant to predicting the activity of chemical germicides under field situations. The method described below uses discs (1 cm in diameter) of brushed stainless steel discs as carriers. Ten mul of the test virus in a soil load is placed on each disc and the inoculum dried under ambient conditions. The dried inoculum is then exposed to 50 mul of the test formulation or a control solution for a defined contact time at the specified temperature. EBSS (0.95 ml) is added to each carrier holder to dilute/neutralize the germicide, the inoculum eluted and the eluates titrated in cell cultures to determine the degree of loss in virus viability. At least five test and three control carriers are used in each test. Controls are also included to test for toxicity of the test formulation to the host cells and any interference sub-cytotoxic levels of the formulation may have on the ability of the virus to infect the cells. The method has been used with several types of human and animal pathogenic viruses to test the activity of all major classes of chemical germicides against them. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [41] Quantitative evaluation of prion inactivation comparing steam sterilization and chemical sterilants: proposed method for test standardization
    Vadrot, C.
    Darbord, J. -C.
    JOURNAL OF HOSPITAL INFECTION, 2006, 64 (02) : 143 - 148
  • [42] AN INDIRECT, QUANTITATIVE METHOD FOR THE ESTIMATION OF HEPARIN ACTIVITY INVITRO - THE HEPARIN-PROTAMINE TITRATION TEST
    LEROY, GV
    HALPERN, B
    DOLKART, RE
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1950, 35 (03): : 446 - 458
  • [43] A simple, rapid, and sensitive fluorescence-based method to assess triacylglycerol hydrolase activity
    Rajan, Sujith
    de Guzman, Hazel C.
    Palaia, Thomas
    Goldberg, Ira J.
    Hussain, M. Mahmood
    JOURNAL OF LIPID RESEARCH, 2021, 62
  • [44] Dynamics and test method of carrier-based aircraft nose landing gear sudden extension
    Wei, Xiaohui
    Liu, Chenglong
    Nie, Hong
    Zhang, Ming
    Yin, Qiaozhi
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2013, 34 (06): : 1363 - 1369
  • [45] Modal Test of Shaft-Mounted Brake Disc Based on PolyMax Modal Parameter Identification Method
    Jiao B.
    Cao J.
    Lü B.
    Zhang H.
    Song Y.
    Chen D.
    1600, Chinese Academy of Railway Sciences (41): : 102 - 107
  • [46] Simulation test for metering process of horizontal disc precision metering device based on discrete element method
    Zhao, W. (zhaowy@gsau.edu.cn), 1600, Chinese Society of Agricultural Engineering (30):
  • [47] General Raman-based method for evaluating the carrier mobilities of chemical vapor deposited graphene
    Woo, Yun Sung
    Lee, Dong Wook
    Kim, Un Jeong
    CARBON, 2018, 132 : 263 - 270
  • [48] An Automatic Test Case Generation Method based on SysML Activity Diagram
    Xu, Yiqun
    Wu, Linbo
    2019 INTERNATIONAL CONFERENCE ON ADVANCED ELECTRONIC MATERIALS, COMPUTERS AND MATERIALS ENGINEERING (AEMCME 2019), 2019, 563
  • [49] A sensitive optical-based test method for the locomotor activity of earthworms
    Xu, Ting
    Zhao, Wanting
    Miao, Juanjuan
    Zhang, Bin
    Yang, Xinyue
    Sheng, G. Daniel
    Yin, Daqiang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 715
  • [50] Study on Determination Method of Rock Tensile Modulus of Brazilian Disc Splitting Test Based on Digital Speckle Correlation Method (DSCM)
    Tongbin Zhao
    Wei Zhang
    Minglu Xing
    Yue Qiu
    Jinpeng Yao
    Arabian Journal for Science and Engineering, 2022, 47 : 4287 - 4300