Liquid chromatography-electrospray ionization-tandem mass spectrometry for simultaneous analysis of chlorogenic acids and their metabolites in human plasma

被引:42
|
作者
Matsui, Yuji [1 ]
Nakamura, Shun [1 ]
Kondou, Naoki [1 ]
Takasu, Yoshio [1 ]
Ochiai, Ryuji [1 ]
Masukawa, Yoshinori [1 ]
机构
[1] Kao Corp, Analyt Res Ctr, Tochigi Res Labs, Haga, Tochigi 3213497, Japan
关键词
chlorogenic acids; human plasma; LC-ESI-MS/MS; metabolite; simultaneous analysis;
D O I
10.1016/j.jchromb.2007.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed for the simultaneous analysis of nine chlorogenic acids (CGAs), three isomers each of caffeoylquinic acids (CQAs), feruloylquinic acids (FQAs) and dicaffeoylquinic acids (dCQAs), and their two metabolites, caffeic acid (CA) and ferulic acid (FA), in human plasma. In simultaneous multiple reaction monitoring (MRM) measurements using ESI-MS/MS with a negative ion mode, a deprotonated molecular ion derived from each of the I I molecules was used as a precursor ion while three diagnostic product ions characteristic for each were selected for the qualitative analysis. To obtain maximal intensities for all diagnostic product ions, the collision energy was optimized for each one. LC separation was achieved under conditions of a reversed-phase Inertsil ODS-2 column combined with a gradient elution system using 50 mM acetic acid with 3% acetonitrile aqueous solution and 50 mN acetic acid with 100% acetonitrile. In the quantitative analysis, one of the three diagnostic product ions for each of the I I molecules was selected. Application of simultaneous LC-ESI-MS/MS MRM measurements to analyze the I I standards spiked into blank human plasma indicated that all diagnostic product ions were detected without any interference, and that the sensitivity, linearity and recovery of this method were acceptable. When using this method to analyze those I I molecules in the plasma after oral ingestion of 250 ml of a drink containing a green coffee bean extract (300 mg CGAs). all 11 molecules were identified and CQAs, FQAs and FA were quantified. CQAs, FQAs and dCQAs in human plasma were detected for the first time. This method should be useful to understand the biological and pharmacological effects of CGAs, such as improvement of human hypertension. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 50 条
  • [41] Rapid determination of total homocysteine in blood spots by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Gempel, K
    Gerbitz, KD
    Casetta, B
    Bauer, MF
    CLINICAL CHEMISTRY, 2000, 46 (01) : 122 - 123
  • [42] Quantitative determination of dihydrostreptomycin in bovine tissues and milk by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Cherlet, Marc
    De Baere, Siegrid
    De Backer, Patrick
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05): : 647 - 656
  • [43] Liquid chromatography-electrospray ionization tandem mass spectrometry for the quantification of styraxlignolide A in rat plasma
    Ji, Hye Y.
    Oh, Sei-Ryang
    Lee, Hyeong-Kyu
    Na, Dong H.
    Lee, Hye S.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1828 - 1833
  • [44] A liquid chromatography-electrospray ionization-tandem mass spectrometry study of ethanolamines in high salinity industrial wastewaters
    Campo, Pablo
    Suidan, Makram T.
    Chai, Yunzhou
    Davis, John
    TALANTA, 2010, 80 (03) : 1110 - 1115
  • [45] Simultaneous determination of 18 tetrahydrocorticosteroid sulfates in human urine by liquid chromatography/electrospray ionization-tandem mass spectrometry
    Mitamura, Kuniko
    Satoh , Rika
    Kamibayashi, Mami
    Sato, Kanta
    Iida, Takashi
    Ikegawa, Shigeo
    STEROIDS, 2014, 85 : 18 - 29
  • [46] Simple and accurate quantitative analysis of 20 anti-tuberculosis drugs in human plasma using liquid chromatography-electrospray ionization-tandem mass spectrometry
    Kim, Hyo-Ji
    Seo, Kyung-Ah
    Kim, Hyun-Mi
    Jeong, Eun-Sook
    Ghim, Jong Lyul
    Lee, Seung Heon
    Lee, Young Min
    Kim, Dong Hyun
    Shin, Jae-Gook
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 102 : 9 - 16
  • [47] Lisinopril quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Padua, AAF
    Barrientos-Astigarraga, RE
    Rezende, VM
    Mendes, GD
    De Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 211 - 216
  • [48] Metabolomic analysis of uremic toxins by liquid chromatography/electrospray ionization-tandem mass spectrometry
    Kikuchi, Kaori
    Itoh, Yoshiharu
    Tateoka, Ryoko
    Ezawa, Atsuko
    Murakami, Kenjiro
    Niwa, Toshimitsu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (20): : 1662 - 1668
  • [49] Quantitation of Armillarisin A in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Wang, Yan
    Wang, Yingwu
    Li, Pengfei
    Tang, Yunbiao
    Fawcett, J. Paul
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1860 - 1863
  • [50] Lansoprazole quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Oliveira, CH
    Barrientos-Astigarraga, RE
    Abib, E
    Mendes, GD
    da Silva, DR
    de Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (02): : 453 - 459