Liquid chromatography-electrospray ionization-tandem mass spectrometry for simultaneous analysis of chlorogenic acids and their metabolites in human plasma

被引:42
|
作者
Matsui, Yuji [1 ]
Nakamura, Shun [1 ]
Kondou, Naoki [1 ]
Takasu, Yoshio [1 ]
Ochiai, Ryuji [1 ]
Masukawa, Yoshinori [1 ]
机构
[1] Kao Corp, Analyt Res Ctr, Tochigi Res Labs, Haga, Tochigi 3213497, Japan
关键词
chlorogenic acids; human plasma; LC-ESI-MS/MS; metabolite; simultaneous analysis;
D O I
10.1016/j.jchromb.2007.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed for the simultaneous analysis of nine chlorogenic acids (CGAs), three isomers each of caffeoylquinic acids (CQAs), feruloylquinic acids (FQAs) and dicaffeoylquinic acids (dCQAs), and their two metabolites, caffeic acid (CA) and ferulic acid (FA), in human plasma. In simultaneous multiple reaction monitoring (MRM) measurements using ESI-MS/MS with a negative ion mode, a deprotonated molecular ion derived from each of the I I molecules was used as a precursor ion while three diagnostic product ions characteristic for each were selected for the qualitative analysis. To obtain maximal intensities for all diagnostic product ions, the collision energy was optimized for each one. LC separation was achieved under conditions of a reversed-phase Inertsil ODS-2 column combined with a gradient elution system using 50 mM acetic acid with 3% acetonitrile aqueous solution and 50 mN acetic acid with 100% acetonitrile. In the quantitative analysis, one of the three diagnostic product ions for each of the I I molecules was selected. Application of simultaneous LC-ESI-MS/MS MRM measurements to analyze the I I standards spiked into blank human plasma indicated that all diagnostic product ions were detected without any interference, and that the sensitivity, linearity and recovery of this method were acceptable. When using this method to analyze those I I molecules in the plasma after oral ingestion of 250 ml of a drink containing a green coffee bean extract (300 mg CGAs). all 11 molecules were identified and CQAs, FQAs and FA were quantified. CQAs, FQAs and dCQAs in human plasma were detected for the first time. This method should be useful to understand the biological and pharmacological effects of CGAs, such as improvement of human hypertension. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 50 条
  • [21] Simultaneous determination of aconitine, mesaconitine, hypaconitine, bulleyaconitine and lappaconitine in human urine by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Li, Mei
    Cai, Zongwei
    ANALYTICAL METHODS, 2013, 5 (16) : 4034 - 4038
  • [22] Regiospecific Analysis of Triacylglycerols by Ultrahigh-Performance-Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Tarvainen, Marko
    Kallio, Heikki
    Yang, Baoru
    ANALYTICAL CHEMISTRY, 2019, 91 (21) : 13695 - 13702
  • [23] Quantitative Determination of Four Nitrofurans and Corresponding Metabolites in the Fish Muscle by Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Tsai, Chung-Wei
    Tang, Chuan-Ho
    Wang, Wei-Hsien
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2010, 18 (02) : 98 - 106
  • [24] Quantification of clomiphene metabolite isomers in human plasma by rapid-resolution liquid chromatography-electrospray ionization-tandem mass spectrometry
    Ganchev, Boian
    Heinkele, Georg
    Kerb, Reinhold
    Schwab, Matthias
    Muerdter, Thomas E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (10) : 3429 - 3441
  • [25] Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Fang, WB
    Andrenyak, DM
    Moody, DE
    Nuwayser, ES
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (03) : 169 - 174
  • [26] Determination of Total Choline by Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry in Infant Formulas
    Fu, Shishan
    Tao, Baohua
    Lai, Shiyun
    Zhang, Jingshun
    Ren Yiping
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (01) : 157 - 162
  • [27] The in vivo glucuronidation of buprenorphine and norbuprenorphine determined by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Huang, W
    Moody, DE
    McCance-Katz, EF
    THERAPEUTIC DRUG MONITORING, 2006, 28 (02) : 245 - 251
  • [28] Rapid and accurate determination of dichlorvos in water by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Yang, Lan
    Liu, Yan Hong
    An, Li Zhe
    Li, You-bin
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (20) : 2943 - 2955
  • [29] Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry
    Byeon, Seul Kee
    Lee, Ju Yong
    Moon, Myeong Hee
    ANALYST, 2012, 137 (02) : 451 - 458
  • [30] Determination of nitrofuran metabolites in milk by liquid chromatography-electrospray ionization tandem mass spectrometry
    Rodziewicz, Lech
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 156 - 160