Liquid chromatography-electrospray ionization-tandem mass spectrometry for simultaneous analysis of chlorogenic acids and their metabolites in human plasma

被引:42
|
作者
Matsui, Yuji [1 ]
Nakamura, Shun [1 ]
Kondou, Naoki [1 ]
Takasu, Yoshio [1 ]
Ochiai, Ryuji [1 ]
Masukawa, Yoshinori [1 ]
机构
[1] Kao Corp, Analyt Res Ctr, Tochigi Res Labs, Haga, Tochigi 3213497, Japan
关键词
chlorogenic acids; human plasma; LC-ESI-MS/MS; metabolite; simultaneous analysis;
D O I
10.1016/j.jchromb.2007.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed for the simultaneous analysis of nine chlorogenic acids (CGAs), three isomers each of caffeoylquinic acids (CQAs), feruloylquinic acids (FQAs) and dicaffeoylquinic acids (dCQAs), and their two metabolites, caffeic acid (CA) and ferulic acid (FA), in human plasma. In simultaneous multiple reaction monitoring (MRM) measurements using ESI-MS/MS with a negative ion mode, a deprotonated molecular ion derived from each of the I I molecules was used as a precursor ion while three diagnostic product ions characteristic for each were selected for the qualitative analysis. To obtain maximal intensities for all diagnostic product ions, the collision energy was optimized for each one. LC separation was achieved under conditions of a reversed-phase Inertsil ODS-2 column combined with a gradient elution system using 50 mM acetic acid with 3% acetonitrile aqueous solution and 50 mN acetic acid with 100% acetonitrile. In the quantitative analysis, one of the three diagnostic product ions for each of the I I molecules was selected. Application of simultaneous LC-ESI-MS/MS MRM measurements to analyze the I I standards spiked into blank human plasma indicated that all diagnostic product ions were detected without any interference, and that the sensitivity, linearity and recovery of this method were acceptable. When using this method to analyze those I I molecules in the plasma after oral ingestion of 250 ml of a drink containing a green coffee bean extract (300 mg CGAs). all 11 molecules were identified and CQAs, FQAs and FA were quantified. CQAs, FQAs and dCQAs in human plasma were detected for the first time. This method should be useful to understand the biological and pharmacological effects of CGAs, such as improvement of human hypertension. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 50 条
  • [31] Simultaneous determination of hair cortisol, cortisone and DHEAS with liquid chromatography-electrospray ionization-tandem mass spectrometry in negative mode
    Chen, Zheng
    Li, Jifeng
    Zhang, Jing
    Xing, Xue
    Gao, Wei
    Lu, Zuhong
    Deng, Huihua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 929 : 187 - 194
  • [32] Simple and practical derivatization procedure for enhanced detection of carboxylic acids in liquid chromatography-electrospray ionization-tandem mass spectrometry
    Higashi, Tatsuya
    Ichikawa, Takuya
    Inagaki, Shinsuke
    Min, Jun Zhe
    Fukushima, Takeshi
    Toyo'oka, Toshimasa
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (05) : 809 - 818
  • [33] Solid phase microextraction with liquid chromatography-electrospray ionization-tandem mass spectrometry for analysis of amphetamine and methamphetamine in serum
    Chou, CC
    Lee, MR
    ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 49 - 56
  • [34] Analysis of trans-3′-hydroxynorcotinine in smokers' urine by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Upadhyaya, Pramod
    Hecht, Stephen S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [35] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Laiel C. Soliman
    Elizabeth M. Andrucson
    Kingsley K. Donkor
    John S. Church
    Bruno Cinel
    Food Analytical Methods, 2016, 9 : 630 - 637
  • [36] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Soliman, Laiel C.
    Andrucson, Elizabeth M.
    Donkor, Kingsley K.
    Church, John S.
    Cinel, Bruno
    FOOD ANALYTICAL METHODS, 2016, 9 (03) : 630 - 637
  • [37] Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry as an Alternative Proteomics Platform to Ultraperformance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry for Samples of Intermediate Complexity
    Li, Yihan
    Champion, Matthew M.
    Sun, Liangliang
    Champion, Patricia A. DiGiuseppe
    Wojcik, Roza
    Dovichi, Norman J.
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1617 - 1622
  • [38] Simultaneous quantitative analysis of dextromethorphan, dextrorphan and chlorphenamine in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Ding, Ying
    Huang, Kai
    Chen, Lan
    Yang, Jie
    Xu, Wen-Yan
    Xu, Xue-Jiao
    Duan, Ru
    Zhang, Jing
    He, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (03) : 446 - 452
  • [39] Determination of dansylated monoamine and amino acid neurotransmitters and their metabolites in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Cai, Hua-Lin
    Zhu, Rong-Hua
    Li, Huan-De
    ANALYTICAL BIOCHEMISTRY, 2010, 396 (01) : 103 - 111
  • [40] Lipidomic profiling of wild cordyceps and its substituents by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Lin, Manting
    Guo, Shan
    Xie, Di
    Li, Sheng
    Hu, Hankun
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2022, 163