Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty

被引:10
|
作者
Castagnini, Francesco [1 ]
Bordini, Barbara [2 ]
Yorifuji, Makiko [2 ,3 ]
Giardina, Federico [1 ]
Natali, Simone [1 ]
Pardo, Francesco [1 ]
Traina, Francesco [1 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Ortopedia Traumatol & Chirurg Protes & Reimpianti, Via Pupilli 1, IT-40136 Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[3] Tokyo Med Univ, Dept Orthoped Surg, Tokyo, Japan
关键词
Ti-Por; Additive manufacturing; Electron beam melting; Pore; Highly porous titanium cups; ACETABULAR COMPONENT; RANDOMIZED-TRIAL; INGROWTH; BONE; PERFORMANCE; IMPLANTS; SIZE;
D O I
10.1159/000500876
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Highly porous titanium cups have been recently introduced, with contradictory outcomes. A retrospective consecutive case series involving bilateral metachronous total hip arthroplasties (THA) performed with 2 different cups, i.e., Fixa (F) and Fixa Ti-Por (T) (Adler Ortho, Milan, Italy), and the same stem, was evaluated. T sockets, manufactured using electron beam melting, were supposed to prove superior in terms of clinical results, survival rates, and radiographic parameters in comparison to hydroxyapatite-coated F cups with conventional porosity. Subjects and Methods: Twenty-four bilateral metachronous THAs with an F cup on one side and a T socket on the other side were evaluated. Preoperative and postoperative Harris hip scores (HHS) were collected for every patient. Radiographic signs of loosening were assessed. The radiographic signs of osseointegration (radiolucent lines, superolateral buttress, inferomedial buttress, radial trabeculae, and stress shielding) were evaluated. Results: No intraoperative complications occurred. The mean HHS score was excellent and comparable in both groups. At the mean follow-up of 134 months (F) and 79 months (T), no cup or liner revisions were performed. No radiographic signs of loosening were reported. All of the patients revealed 3 parameters of good bony ingrowth at least. Both groups showed similar radiographic parameters regarding osseointegration, which were stable over the time. Stress shielding was more evident in the T cohort (p =0.07). Conclusion: Highly porous titanium cups produced using an additive manufacturing and electron beam melting technology achieved reliable midterm clinical and radiographic results not inferior to those of second-generation cups.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [41] Fracture of fully hydroxyapatite-coated titanium femoral stem of a total hip replacement - a report of 3 cases
    Sharma, DK
    Brooks, S
    Creasey, S
    Lewis, B
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06): : 768 - 771
  • [42] Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem
    Castellini, Iacopo
    Andreani, Lorenzo
    Parchi, Paolo Domenico
    Bonicoli, Enrico
    Piolanti, Nicola
    Risoli, Francesca
    Lisanti, Michele
    CLINICAL CASES IN MINERAL AND BONE METABOLISM, 2016, 13 (03) : 221 - 227
  • [43] Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine study
    Anke Eckardt
    Harold M. Aberman
    Dan H. Cantwell
    Jochen Heine
    Archives of Orthopaedic and Trauma Surgery, 2003, 123 : 28 - 35
  • [44] Hydroxyapatite-coated femoral stems in primary total hip arthroplasty: A meta-analysis of randomized controlled trials
    Li, Shuzhen
    Huang, Baohua
    Chen, Yueping
    Gao, Hui
    Fan, Qie
    Zhao, Jinmin
    Su, Wei
    INTERNATIONAL JOURNAL OF SURGERY, 2013, 11 (06) : 477 - 482
  • [45] BONE INGROWTH ANALYSIS AND INTERFACE EVALUATION OF HYDROXYAPATITE-COATED VERSUS UNCOATED TITANIUM POROUS BONE IMPLANTS
    MORONI, A
    CAJA, VL
    SABATO, C
    EGGER, EL
    GOTTSAUNERWOLF, F
    CHAO, EYS
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) : 411 - 416
  • [46] Total Hip Arthroplasty With a Fully Hydroxyapatite-Coated Stem: A Cohort Study During 23-28 Years
    Reikeras, Olav
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1543 - 1546
  • [47] Midterm Results of Femoral Impaction Bone Grafting With an Allograft Combined With Hydroxyapatite in Revision Total Hip Arthroplasty
    Oshima, Seigo
    Yasunaga, Yuji
    Yamasaki, Takuma
    Yoshida, Tomokazu
    Hori, Junji
    Ochi, Mitsuo
    JOURNAL OF ARTHROPLASTY, 2012, 27 (03): : 470 - 476
  • [48] Results of a Hydroxyapatite-Coated Modular Femoral Stem in Primary Total Hip Arthroplasty. A Minimum 5-Year Follow-Up
    Garcia-Rey, Eduardo
    Munoz, Teresa
    Montejo, Jorge
    Martinez, Javier
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1132 - 1139
  • [50] Midterm Results of Primary Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene
    Lee, Ji-Ho
    Lee, Byung Woo
    Lee, Byoung-Joo
    Kim, Shin-Yoon
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1014 - 1019