Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty

被引:10
|
作者
Castagnini, Francesco [1 ]
Bordini, Barbara [2 ]
Yorifuji, Makiko [2 ,3 ]
Giardina, Federico [1 ]
Natali, Simone [1 ]
Pardo, Francesco [1 ]
Traina, Francesco [1 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Ortopedia Traumatol & Chirurg Protes & Reimpianti, Via Pupilli 1, IT-40136 Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[3] Tokyo Med Univ, Dept Orthoped Surg, Tokyo, Japan
关键词
Ti-Por; Additive manufacturing; Electron beam melting; Pore; Highly porous titanium cups; ACETABULAR COMPONENT; RANDOMIZED-TRIAL; INGROWTH; BONE; PERFORMANCE; IMPLANTS; SIZE;
D O I
10.1159/000500876
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Highly porous titanium cups have been recently introduced, with contradictory outcomes. A retrospective consecutive case series involving bilateral metachronous total hip arthroplasties (THA) performed with 2 different cups, i.e., Fixa (F) and Fixa Ti-Por (T) (Adler Ortho, Milan, Italy), and the same stem, was evaluated. T sockets, manufactured using electron beam melting, were supposed to prove superior in terms of clinical results, survival rates, and radiographic parameters in comparison to hydroxyapatite-coated F cups with conventional porosity. Subjects and Methods: Twenty-four bilateral metachronous THAs with an F cup on one side and a T socket on the other side were evaluated. Preoperative and postoperative Harris hip scores (HHS) were collected for every patient. Radiographic signs of loosening were assessed. The radiographic signs of osseointegration (radiolucent lines, superolateral buttress, inferomedial buttress, radial trabeculae, and stress shielding) were evaluated. Results: No intraoperative complications occurred. The mean HHS score was excellent and comparable in both groups. At the mean follow-up of 134 months (F) and 79 months (T), no cup or liner revisions were performed. No radiographic signs of loosening were reported. All of the patients revealed 3 parameters of good bony ingrowth at least. Both groups showed similar radiographic parameters regarding osseointegration, which were stable over the time. Stress shielding was more evident in the T cohort (p =0.07). Conclusion: Highly porous titanium cups produced using an additive manufacturing and electron beam melting technology achieved reliable midterm clinical and radiographic results not inferior to those of second-generation cups.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [31] Hydroxyapatite-Coated Femoral Stems in Primary Total Hip Arthroplasty: An Updated Meta-Analysis
    Kim, William T.
    Woodruff, Robert
    Kalore, Niraj V.
    Vallem, Madan M.
    Cyrus, John W.
    Krumme, John W.
    Patel, Nirav K.
    Golladay, Gregory J.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (03): : 846 - 850.e2
  • [32] Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem
    Froimson, Mark I.
    Garino, Jonathan
    Machenaud, Alan
    Vidalain, J. P.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (01): : 1 - 7
  • [33] RADIOGRAPHIC PATTERNS IN TOTAL HIP-ARTHROPLASTY - HYDROXYAPATITE-COATED AND UNCOATED FEMORAL STEM PROSTHESES
    FOX, MG
    RAK, KM
    LISECKI, EJ
    CASTELLO, PH
    RADIOLOGY, 1995, 197 : 396 - 396
  • [34] Long-term results of a hydroxyapatite-coated femoral component in total hip replacement
    Rajaratnam, S. S.
    Jack, C.
    Tavakkolizadeh, A.
    George, M. D.
    Fletcher, R. J.
    Hankins, M.
    Shepperd, J. A. N.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (01): : 27 - 30
  • [35] Highly porous titanium cup in cementless total hip arthroplasty: registry results at eight years
    Castagnini, Francesco
    Bordini, Barbara
    Stea, Susanna
    Calderoni, Pierina Paola
    Masetti, Claudio
    Busanelli, Luca
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (08) : 1815 - 1821
  • [36] Highly porous titanium cup in cementless total hip arthroplasty: registry results at eight years
    Francesco Castagnini
    Barbara Bordini
    Susanna Stea
    Pierina Paola Calderoni
    Claudio Masetti
    Luca Busanelli
    International Orthopaedics, 2019, 43 : 1815 - 1821
  • [37] MICROMOTION OF FEMORAL STEMS IN TOTAL HIP-ARTHROPLASTY - A RANDOMIZED STUDY OF CEMENTED, HYDROXYAPATITE-COATED, AND POROUS-COATED STEMS WITH ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
    KARRHOLM, J
    MALCHAU, H
    SNORRASON, F
    HERBERTS, P
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (11): : 1692 - 1705
  • [38] Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study
    Ohta, Yoichi
    Sugama, Ryo
    Minoda, Yukihide
    Mizokawa, Shigekazu
    Takahashi, Shinji
    Ikebuchi, Mitsuhiko
    Nakatsuchi, Tamotsu
    Nakamura, Hiroaki
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [39] Fully hydroxyapatite-coated collared femoral stems in direct anterior versus direct lateral hip arthroplasty
    Heaven, Sebastian
    Perelgut, Maxwell
    Vasarhelyi, Edward
    Howard, James
    Teeter, Matthew
    Lanting, Brent
    CANADIAN JOURNAL OF SURGERY, 2021, 64 (02) : E205 - E210
  • [40] Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine study
    Eckardt, A
    Aberman, HM
    Cantwell, HD
    Heine, J
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (01) : 28 - 35