Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty

被引:10
|
作者
Castagnini, Francesco [1 ]
Bordini, Barbara [2 ]
Yorifuji, Makiko [2 ,3 ]
Giardina, Federico [1 ]
Natali, Simone [1 ]
Pardo, Francesco [1 ]
Traina, Francesco [1 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Ortopedia Traumatol & Chirurg Protes & Reimpianti, Via Pupilli 1, IT-40136 Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[3] Tokyo Med Univ, Dept Orthoped Surg, Tokyo, Japan
关键词
Ti-Por; Additive manufacturing; Electron beam melting; Pore; Highly porous titanium cups; ACETABULAR COMPONENT; RANDOMIZED-TRIAL; INGROWTH; BONE; PERFORMANCE; IMPLANTS; SIZE;
D O I
10.1159/000500876
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Highly porous titanium cups have been recently introduced, with contradictory outcomes. A retrospective consecutive case series involving bilateral metachronous total hip arthroplasties (THA) performed with 2 different cups, i.e., Fixa (F) and Fixa Ti-Por (T) (Adler Ortho, Milan, Italy), and the same stem, was evaluated. T sockets, manufactured using electron beam melting, were supposed to prove superior in terms of clinical results, survival rates, and radiographic parameters in comparison to hydroxyapatite-coated F cups with conventional porosity. Subjects and Methods: Twenty-four bilateral metachronous THAs with an F cup on one side and a T socket on the other side were evaluated. Preoperative and postoperative Harris hip scores (HHS) were collected for every patient. Radiographic signs of loosening were assessed. The radiographic signs of osseointegration (radiolucent lines, superolateral buttress, inferomedial buttress, radial trabeculae, and stress shielding) were evaluated. Results: No intraoperative complications occurred. The mean HHS score was excellent and comparable in both groups. At the mean follow-up of 134 months (F) and 79 months (T), no cup or liner revisions were performed. No radiographic signs of loosening were reported. All of the patients revealed 3 parameters of good bony ingrowth at least. Both groups showed similar radiographic parameters regarding osseointegration, which were stable over the time. Stress shielding was more evident in the T cohort (p =0.07). Conclusion: Highly porous titanium cups produced using an additive manufacturing and electron beam melting technology achieved reliable midterm clinical and radiographic results not inferior to those of second-generation cups.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [21] Migration and wear of hydroxyapatite-coated press-fit cups in revision hip arthroplasty -: A radiostereometric study
    Nivbrant, B
    Kärrholm, J
    JOURNAL OF ARTHROPLASTY, 1997, 12 (08): : 904 - 912
  • [22] Comparison of a highly porous titanium cup (Tritanium) and a conventional hydroxyapatite-coated porous titanium cup: A retrospective analysis of clinical and radiological outcomes in hip arthroplasty among Japanese patients
    Yoshioka, Shinji
    Nakano, Shunji
    Kinoshita, Yutaka
    Nakamura, Masaru
    Goto, Tomohiro
    Hamada, Daisuke
    Sairyo, Koichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (06) : 967 - 972
  • [23] Survivorship and Radiological Analysis of a Monoblock, Hydroxyapatite-Coated Titanium Stem in Revision Hip Arthroplasty
    Saunders, Paul R. J.
    Shaw, Debbie A.
    Sidharthan, Sijin K.
    Siney, Paul D.
    Young, Stephen K.
    Board, Tim N.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : 1678 - 1685
  • [24] Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell
    Delanois, Ronald E.
    Gwam, Chukwuweike U.
    Mohamed, Nequesha
    Khlopas, Anton
    Chughtai, Morad
    Malkani, Arthur L.
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : 2806 - 2809
  • [25] Ten-year results of ALIZE acetabular cup with hydroxyapatite coating and AURA hydroxyapatite-coated stem in total hip arthroplasty
    Fayard, Jean-Philippe
    Chalencon, Francois
    Passot, Jean-Paul
    Latour, Laurent Dupre
    Edorh, Gregoire
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1021 - 1025
  • [26] Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem:: results at a minimum of 10 years' follow-up in 104 hips
    Bodén, H
    Salemyr, M
    Sköldenberg, O
    Ahl, T
    Adolphson, P
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (02) : 175 - 179
  • [27] Natural progress of a bone scan after cementless hydroxyapatite-coated total hip arthroplasty
    Suh, KT
    Lee, CB
    Kim, IJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (389) : 134 - 142
  • [28] Hydroxyapatite-coated femoral components in total knee arthroplasty - Medium term results
    Murty, AN
    Scott, G
    Freeman, MAR
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 844 - 851
  • [29] 6-YEAR RESULTS OF HYDROXYAPATITE-COATED TOTAL HIP-REPLACEMENT
    GEESINK, RGT
    HOEFNAGELS, NHM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (04): : 534 - 547
  • [30] Fully hydroxyapatite-coated total hip replacement: ten-year results
    Valera Pertegas, Marius
    Vergara-Valladolid, Pedro
    Crusi-Sererols, Xavier
    Sancho-Navarro, Rogelio
    HIP INTERNATIONAL, 2010, 20 : S79 - S85