Bayesian Approach for Peak Detection in Two-Dimensional Chromatography

被引:37
|
作者
Vivo-Truyols, Gabriel [1 ]
机构
[1] Univ Amsterdam, Analyt Chem Grp, vant Hoff Inst Mol Sci, NL-1098 XH Amsterdam, Netherlands
关键词
LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; ALGORITHM;
D O I
10.1021/ac202124t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for peak detection in two-dimensional chromatography is presented. In a first step, the method starts with a conventional one-dimensional peak detection algorithm to detect constructed to decide which of the individual one-dimensional peaks modulated peaks. In a second step, a sophisticated algorithm is have been originated from the same compound and should then be arranged in a two-dimensional peak. The merging algorithm is based on Bayesian inference. The user sets prior information about certain parameters (e.g., second-dimension retention time variability, first-dimension band broadening, chromatographic noise). On the basis of these priors, the algorithm calculates the probability of myriads of peak arrangements (i.e., ways of merging one-dimensional peaks), finding which of them holds the highest value. Uncertainty in each parameter can be accounted by adapting conveniently its probability distribution function, which in turn may change the final decision of the most probable peak arrangement. It has been demonstrated that the Bayesian approach presented in this paper follows the chromatographers' intuition. The algorithm has been applied and tested with LC x LC and GC x GC data and takes around 1 min to process chromatograms with several thousands of peaks.
引用
收藏
页码:2622 / 2630
页数:9
相关论文
共 50 条
  • [31] Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions
    Seeley, John, V
    Schimmel, Nicolaas E.
    Seeley, Stacy K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (13) : 2399 - 2409
  • [32] Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions
    John V. Seeley
    Nicolaas E. Schimmel
    Stacy K. Seeley
    Analytical and Bioanalytical Chemistry, 2023, 415 : 2399 - 2409
  • [33] Improving peak shapes with counter gradients in two-dimensional high performance liquid chromatography
    Stevenson, Paul G.
    Bassanese, Danielle N.
    Conlan, Xavier A.
    Barnett, Neil W.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1337 : 147 - 154
  • [34] Evaluation of the impact of peak description on the quantitative capabilities of comprehensive two-dimensional liquid chromatography
    Place, Benjamin J.
    Morris, Mallory J.
    Phillips, Melissa M.
    Sander, Lane C.
    Rimmer, Catherine A.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1368 : 107 - 115
  • [35] A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time
    Thekkudan, Dennis F.
    Rutan, Sarah C.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4313 - 4327
  • [36] Peak picking and the assessment of separation performance in two-dimensional high performance liquid chromatography
    Stevenson, Paul G.
    Mnatsakanyan, Mariam
    Guiochon, Georges
    Shalliker, R. Andrew
    ANALYST, 2010, 135 (07) : 1541 - 1550
  • [37] An improved peak clustering algorithm for comprehensive two-dimensional liquid chromatography data analysis
    Xu, Jucai
    Zheng, Lin
    Su, Guowan
    Sun, Baoguo
    Zhao, Mouming
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 273 - 283
  • [38] Influence of temperature on peak shape and solvent compatibility: Implications for two-dimensional liquid chromatography
    Haun, Jakob
    Teutenberg, Thorsten
    Schmidt, Torsten C.
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (14) : 1723 - 1730
  • [39] Complementarity of two-dimensional gas chromatography and two-dimensional liquid chromatography for the analysis of depolymerised lignin
    Tammekivi, Eliise
    Lilti, Hugo
    Batteau, Magali
    Lorentz, Chantal
    Geantet, Christophe
    Laurenti, Dorothee
    Faure, Karine
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1736
  • [40] Two-dimensional chromatography of complex polymers Part 1. Analysis of a graft copolymer by two-dimensional chromatography with on-line FTIR detection
    Adrian, J
    Esser, E
    Hellmann, G
    Pasch, H
    POLYMER, 2000, 41 (07) : 2439 - 2449