Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions

被引:3
|
作者
Seeley, John, V [1 ]
Schimmel, Nicolaas E. [1 ]
Seeley, Stacy K. [2 ]
机构
[1] Oakland Univ, Dept Chem, Rochester, MI 48309 USA
[2] Mott Community Coll, Div Arts & Sci, Flint, MI 48504 USA
关键词
Gas chromatography; Two-dimensional separation; Flow modulation; Peak modeling; Secondary column; MASS-SPECTROMETRY; THERMAL MODULATOR;
D O I
10.1007/s00216-022-04387-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study examines how the height and width of peaks exiting the secondary column of a comprehensive two-dimensional gas chromatography (GC x GC) separation are affected by the width of the pulse introduced to the secondary column. A flow-modulated GC x GC apparatus was assembled that allowed input pulse widths to be controlled precisely over a range of 10 to 70 ms. GC x GC chromatograms were obtained using secondary columns containing a polyethylene glycol stationary phase with internal diameters of 0.25 and 0.32 mm. The area, height, and width of peaks emerging from the secondary column were found to be accurately modeled by the convolution of a rectangular function with a Gaussian distribution. The rectangular function represents the input pulse, and the Gaussian distribution represents the broadening that occurs in the secondary column. The minimum peak width that could be produced by the secondary column was determined for a wide range of compounds. Injection pulse widths that matched a compound's minimum peak width produced peaks that were 25% wider than the minimum width and had heights that were 76% of the maximum possible peak height. Increasing the injection width significantly above the minimum width yielded substantially broader peaks with only a modest increase (<25%) in peak height.
引用
收藏
页码:2399 / 2409
页数:11
相关论文
共 50 条
  • [1] Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions
    John V. Seeley
    Nicolaas E. Schimmel
    Stacy K. Seeley
    [J]. Analytical and Bioanalytical Chemistry, 2023, 415 : 2399 - 2409
  • [2] A robust thermal modulator for comprehensive two-dimensional gas chromatography
    Phillips, JB
    Gaines, RB
    Blomberg, J
    van der Wielen, FWM
    Dimandja, JM
    Green, V
    Granger, J
    Patterson, D
    Racovalis, L
    de Geus, HJ
    de Boer, J
    Haglund, P
    Lipsky, J
    Sinha, V
    Ledford, EB
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (01): : 3 - 10
  • [3] Comprehensive two-dimensional gas chromatography with a simple fluidic modulator
    Seeley, John V.
    Micyus, Nicole J.
    McCurry, James D.
    Seeley, Stacy K.
    [J]. AMERICAN LABORATORY, 2006, 38 (09) : 24 - 26
  • [4] COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY USING A MEMS THERMAL MODULATOR
    Paul, D.
    Serrano, G.
    Zellers, E. T.
    Kurabayashi, K.
    [J]. 2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [5] New valve switching modulator for comprehensive two-dimensional gas chromatography
    Wang, Frank Cheng-Yu
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) : 274 - 280
  • [6] The Modulator in Comprehensive Two-Dimensional Liquid Chromatography
    Egeness, Mari J.
    Breadmore, Michael C.
    Hilder, Emily F.
    Shellie, Robert A.
    [J]. LC GC EUROPE, 2016, 29 (05) : 268 - 276
  • [7] Comprehensive Two-Dimensional Gas Chromatography
    Ryan, Danielle
    Marriott, Philip
    [J]. ADVANCES IN CHROMATOGRAPHY, VOL 46, 2008, 46 : 451 - 467
  • [8] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    [J]. LC GC EUROPE, 2004, 17 (02) : 86 - +
  • [9] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    [J]. LC GC NORTH AMERICA, 2004, 22 (01) : 32 - +
  • [10] New liquid nitrogen cryogenic modulator for comprehensive two-dimensional gas chromatography
    Harynuk, J
    Górecki, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) : 53 - 63