Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions

被引:3
|
作者
Seeley, John, V [1 ]
Schimmel, Nicolaas E. [1 ]
Seeley, Stacy K. [2 ]
机构
[1] Oakland Univ, Dept Chem, Rochester, MI 48309 USA
[2] Mott Community Coll, Div Arts & Sci, Flint, MI 48504 USA
关键词
Gas chromatography; Two-dimensional separation; Flow modulation; Peak modeling; Secondary column; MASS-SPECTROMETRY; THERMAL MODULATOR;
D O I
10.1007/s00216-022-04387-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study examines how the height and width of peaks exiting the secondary column of a comprehensive two-dimensional gas chromatography (GC x GC) separation are affected by the width of the pulse introduced to the secondary column. A flow-modulated GC x GC apparatus was assembled that allowed input pulse widths to be controlled precisely over a range of 10 to 70 ms. GC x GC chromatograms were obtained using secondary columns containing a polyethylene glycol stationary phase with internal diameters of 0.25 and 0.32 mm. The area, height, and width of peaks emerging from the secondary column were found to be accurately modeled by the convolution of a rectangular function with a Gaussian distribution. The rectangular function represents the input pulse, and the Gaussian distribution represents the broadening that occurs in the secondary column. The minimum peak width that could be produced by the secondary column was determined for a wide range of compounds. Injection pulse widths that matched a compound's minimum peak width produced peaks that were 25% wider than the minimum width and had heights that were 76% of the maximum possible peak height. Increasing the injection width significantly above the minimum width yielded substantially broader peaks with only a modest increase (<25%) in peak height.
引用
收藏
页码:2399 / 2409
页数:11
相关论文
共 50 条
  • [31] Comprehensive two-dimensional gas chromatography: a hyphenated method with strong coupling between the two dimensions
    Phillips, JB
    Beens, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) : 331 - 347
  • [32] Thermal Independent Modulator for Comprehensive Two Dimensional Gas Chromatography
    Luong, Jim
    Guan, Xiaosheng
    Xu, Shifen
    Gras, Ronda
    Shellie, Robert A.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (17) : 8428 - 8432
  • [33] Modeling of the first dimensional peak with two modulated sub-peaks in comprehensive two-dimensional gas chromatography
    Mao, Hui
    Jiang, Ming
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (13) : 2425 - 2434
  • [34] Modeling of the first dimensional peak with two modulated sub-peaks in comprehensive two-dimensional gas chromatography
    Hui Mao
    Ming Jiang
    [J]. Analytical and Bioanalytical Chemistry, 2023, 415 : 2425 - 2434
  • [35] Development of an algorithm for peak detection in comprehensive two-dimensional chromatography
    Peters, Sonja
    Vivo-Truyols, Gabriel
    Marriott, Philip J.
    Schoenmakers, Peter J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) : 14 - 24
  • [36] Partial modulation method via pulsed flow modulator for comprehensive two-dimensional gas chromatography
    Cai, HM
    Stearns, SD
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (20) : 6064 - 6076
  • [37] Effects of variation in modulator temperature during cryogenic modulation in comprehensive two-dimensional gas chromatography
    Begnaud, Frederic
    Debonneville, Christian
    Probst, Jean-Pierre
    Chaintreau, Alain
    Morrison, Paul D.
    Adcock, Jacqui L.
    Marriott, Philip J.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) : 3144 - 3151
  • [38] Development of a new consumable-free thermal modulator for comprehensive two-dimensional gas chromatography
    Panic, Ognjen
    Gorecki, Tadeusz
    McNeish, Christopher
    Goldstein, Allen H.
    Williams, Brent J.
    Worton, David R.
    Hering, Susanne V.
    Kreisberg, Nathan M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (20) : 3070 - 3079
  • [39] Development and Design of a Single-Stage Cryogenic Modulator for Comprehensive Two-Dimensional Gas Chromatography
    Mostafa, Ahmed
    Gorecki, Tadeusz
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (10) : 5414 - 5423
  • [40] Achieving high peak capacity production for gas chromatography and comprehensive two-dimensional gas chromatography by minimizing off-column peak broadening
    Wilson, Ryan B.
    Siegler, W. Christopher
    Hoggard, Jamin C.
    Fitz, Brian D.
    Nadeau, Jeremy S.
    Synovec, Robert E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3130 - 3139