Calibration transfer and drift counteraction in chemical sensor arrays using Direct Standardization

被引:151
|
作者
Fonollosa, J. [1 ,2 ,3 ]
Fernandez, L. [2 ,3 ]
Gutierrez-Galvez, A. [2 ,3 ]
Huerta, R. [1 ]
Marco, S. [2 ,3 ]
机构
[1] Univ Calif San Diego, Biocircuit Inst, La Jolla, CA 92093 USA
[2] Inst Bioengn Catalonia, Barcelona 08028, Spain
[3] Univ Barcelona, Dept Elect Engn, E-08028 Barcelona, Spain
来源
关键词
Chemical sensors; Calibration transfer; MOX sensors; Electronic nose; Direct Standardization; Public dataset; SEMICONDUCTOR GAS SENSORS; ORTHOGONAL SIGNAL CORRECTION; ELECTRONIC NOSE; INSTRUMENTS;
D O I
10.1016/j.snb.2016.05.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and prevented mass-production for some applications. Here, aiming at exploring calibration transfer between chemical sensor arrays, we exposed five twin 8-sensor detection units to different concentration levels of ethanol, ethylene, carbon monoxide, or methane. First, we built calibration models using data acquired with a master unit. Second, to explore the transferability of the calibration models, we used Direct Standardization to map the signals of a slave unit to the space of the master unit in calibration. In particular, we evaluated the transferability of the calibration models to other detection units, and within the same unit measuring days apart. Our results show that signals acquired with one unit can be successfully mapped to the space of a reference unit. Hence, calibration models trained with a master unit can be extended to slave units using a reduced number of transfer samples, diminishing thereby calibration costs. Similarly, signals of a sensing unit can be transformed to match sensor behavior in the past to mitigate drift effects. Therefore, the proposed methodology can reduce calibration costs in mass-production and delay recalibrations due to sensor aging. Acquired dataset is made publicly available.
引用
收藏
页码:1044 / 1053
页数:10
相关论文
共 50 条
  • [1] On-line drift counteraction for metal oxide gas sensor arrays
    Paniagua, M
    Llobet, E
    Brezmes, J
    Vilanova, X
    Correig, X
    Hines, EL
    ELECTRONICS LETTERS, 2003, 39 (01) : 40 - 42
  • [2] Calibration transfer in temperature modulated gas sensor arrays
    Fernandez, L.
    Guney, S.
    Gutierrez-Galvez, A.
    Marco, S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 276 - 284
  • [3] Internal standardization and calibration of surface acoustic wave chemical sensor systems
    Shaffer, RE
    Cygan, MT
    Hart, SJ
    Chung, R
    Nguyen, V
    Dilella, D
    McGill, RA
    ELECTRO-OPTIC, INTEGRATED OPTIC, AND ELECTRONIC TECHNOLOGIES FOR ONLINE CHEMICAL PROCESS MONITORING, 1999, 3537 : 213 - 223
  • [4] The Application of Piecewise Direct Standardization with SNV in Calibration Transfer of Raman Spectra
    Huang Cheng-wei
    Dai Lian-kui
    Dong Xue-feng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (05) : 1279 - 1282
  • [5] Calibration transfer for bioprocess Raman monitoring using Kennard Stone piecewise direct standardization and multivariate algorithms
    Petillot, Laure
    Pewny, Fiona
    Wolf, Martin
    Sanchez, Celia
    Thomas, Fabrice
    Sarrazin, Johan
    Fauland, Katharina
    Katinger, Hermann
    Javalet, Charlotte
    Bonneville, Christophe
    ENGINEERING REPORTS, 2020, 2 (11)
  • [6] A direct comparison transfer microwave power sensor calibration system
    Shan, Y.
    Chua, S. W.
    Neo, H.
    Wu, T.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 512 - 513
  • [7] Comparison of RF Power Sensor Calibration Using a Vector Network Analyzer and a Direct Transfer System
    Angin, Windi Kurnia Perangin
    Kwon, Jae-Yong
    Kang, Tae-Weon
    Kang, No-Weon
    2016 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (URSI AP-RASC), 2016, : 1754 - 1756
  • [8] Generic Model and Case Studies of Microwave Power Sensor Calibration Using Direct Comparison Transfer
    Shan, Yueyan
    Meng, Yu Song
    Lin, Zhiping
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (06) : 1834 - 1839
  • [9] Blind Drift Calibration of Sensor Networks Using Sparse Bayesian Learning
    Wang, Yuzhi
    Yang, Anqi
    Li, Zhan
    Chen, Xiaoming
    Wang, Pengjun
    Yang, Huazhong
    IEEE SENSORS JOURNAL, 2016, 16 (16) : 6249 - 6260
  • [10] Evaluation of calibration transfer strategies between Metal Oxide gas sensor arrays
    Fonollosa, J.
    Neftci, E.
    Huerta, R.
    Marco, S.
    EUROSENSORS 2015, 2015, 120 : 261 - 264