摘要
Inherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and prevented mass-production for some applications. Here, aiming at exploring calibration transfer between chemical sensor arrays, we exposed five twin 8-sensor detection units to different concentration levels of ethanol, ethylene, carbon monoxide, or methane. First, we built calibration models using data acquired with a master unit. Second, to explore the transferability of the calibration models, we used Direct Standardization to map the signals of a slave unit to the space of the master unit in calibration. In particular, we evaluated the transferability of the calibration models to other detection units, and within the same unit measuring days apart. Our results show that signals acquired with one unit can be successfully mapped to the space of a reference unit. Hence, calibration models trained with a master unit can be extended to slave units using a reduced number of transfer samples, diminishing thereby calibration costs. Similarly, signals of a sensing unit can be transformed to match sensor behavior in the past to mitigate drift effects. Therefore, the proposed methodology can reduce calibration costs in mass-production and delay recalibrations due to sensor aging. Acquired dataset is made publicly available.
引用
收藏
页码:1044 / 1053
页数:10
相关论文
共 50 条
  • [31] Direct writing of electronic and sensor materials using a laser transfer technique
    A. Piqué
    D. B. Chrisey
    J. M. Fitz-Gerald
    R. A. McGill
    R. C. Y. Auyeung
    H. D. Wu
    S. Lakeou
    Viet Nguyen
    R. Chung
    M. Duignan
    Journal of Materials Research, 2000, 15 : 1872 - 1875
  • [32] Drift reduction for metal-oxide sensor arrays using canonical correlation regression and partial least squares
    Gutierrez-Osuna, R
    ELECTRONIC NOSES AND OLFACTION 2000, 2000, : 147 - 152
  • [33] Joint calibration of array shape and sensor gain/phase for highly deformed arrays using wideband signals
    Yang, Long
    Yang, Yixin
    Liao, Guisheng
    Guo, Xijing
    SIGNAL PROCESSING, 2019, 165 : 222 - 232
  • [34] Calibration of Chemical Pneumatic Belmonte Esthesiometer Stimuli using a Portable Carbon Dioxide Sensor
    Jayakumar, Varadharajan
    Alabi, Emmanuel B.
    Feng, Yunwei
    Simpson, Trefford L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [35] Using SYSTEM II Power Transfer System to Develop Calibration of Medium Power Sensor
    Yan Daoguang
    Hou Xingbo
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 635 - 638
  • [36] Chemical multi-sensor arrays for liquids monolithic integration using microelectronic technology
    Bratov, A
    Dominguez, C
    DEFENSE AGAINST BIOTERROR: DETECTION TECHNOLOGIES, IMPLEMENTATION STRATEGIES AND COMMERCIAL OPPORTUNITIES, 2005, 1 : 273 - 289
  • [37] A calibration transfer methodology for Standardization of Raman instruments with different spectral resolutions using Double Digital Projection Slit
    Li, Qifeng
    Sun, Xueqing
    Ma, Xiangyun
    Li, Bin
    Wang, Huijie
    Lv, Haiyue
    Wang, Qing
    Xu, Kexin
    Chen, Da
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2019, 191 : 143 - 147
  • [38] Direct visualization of molecular scale chemical adsorptions on solids using plasmonic nanoparticle arrays
    Wang, Chaoming
    Ma, Liyuan
    Hossain, Mainul
    Wang, Haining
    Zou, Shengli
    Hickman, James J.
    Su, Ming
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (02): : 667 - 672
  • [39] Research on Application of Direct Standardization Algorithm in Near-Infrared Spectrum Calibration Transfer of Acid Value and Peroxide Value of Edible Oil
    Liu Cui-ling
    Li Tian-rui
    Wei Li-na
    Xu Ying-ying
    Wu Jing-zhu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (10) : 3042 - 3050
  • [40] Tailored Graphene Micropatterns by Wafer-Scale Direct Transfer for Flexible Chemical Sensor Platform
    Kim, Yeonhoo
    Kim, Taehoon
    Lee, Jinwoo
    Choi, Yong Seok
    Moon, Joonhee
    Park, Seo Yun
    Lee, Tae Hyung
    Park, Hoon Kee
    Lee, Sol A.
    Kwon, Min Sang
    Byun, Hyung-Gi
    Lee, Jong-Heun
    Lee, Myoung-Gyu
    Hong, Byung Hee
    Jang, Ho Won
    ADVANCED MATERIALS, 2021, 33 (02)