Calibration transfer and drift counteraction in chemical sensor arrays using Direct Standardization

被引:151
|
作者
Fonollosa, J. [1 ,2 ,3 ]
Fernandez, L. [2 ,3 ]
Gutierrez-Galvez, A. [2 ,3 ]
Huerta, R. [1 ]
Marco, S. [2 ,3 ]
机构
[1] Univ Calif San Diego, Biocircuit Inst, La Jolla, CA 92093 USA
[2] Inst Bioengn Catalonia, Barcelona 08028, Spain
[3] Univ Barcelona, Dept Elect Engn, E-08028 Barcelona, Spain
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2016年 / 236卷
关键词
Chemical sensors; Calibration transfer; MOX sensors; Electronic nose; Direct Standardization; Public dataset; SEMICONDUCTOR GAS SENSORS; ORTHOGONAL SIGNAL CORRECTION; ELECTRONIC NOSE; INSTRUMENTS;
D O I
10.1016/j.snb.2016.05.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and prevented mass-production for some applications. Here, aiming at exploring calibration transfer between chemical sensor arrays, we exposed five twin 8-sensor detection units to different concentration levels of ethanol, ethylene, carbon monoxide, or methane. First, we built calibration models using data acquired with a master unit. Second, to explore the transferability of the calibration models, we used Direct Standardization to map the signals of a slave unit to the space of the master unit in calibration. In particular, we evaluated the transferability of the calibration models to other detection units, and within the same unit measuring days apart. Our results show that signals acquired with one unit can be successfully mapped to the space of a reference unit. Hence, calibration models trained with a master unit can be extended to slave units using a reduced number of transfer samples, diminishing thereby calibration costs. Similarly, signals of a sensing unit can be transformed to match sensor behavior in the past to mitigate drift effects. Therefore, the proposed methodology can reduce calibration costs in mass-production and delay recalibrations due to sensor aging. Acquired dataset is made publicly available.
引用
收藏
页码:1044 / 1053
页数:10
相关论文
共 50 条
  • [41] Pharmaceutical analysis in solids using front face fluorescence spectroscopy and multivariate calibration with matrix correction by piecewise direct standardization
    Alves, Julio Cesar L.
    Poppi, Ronei J.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 103 : 311 - 318
  • [42] Diamond-on-Polymer Microelectrode Arrays Fabricated Using a Chemical Release Transfer Process
    Hess, Allison E.
    Sabens, David M.
    Martin, Heidi B.
    Zorman, Christian A.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (04) : 867 - 875
  • [43] CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES
    BOUVERESSE, E
    MASSART, DL
    DARDENNE, P
    ANALYTICA CHIMICA ACTA, 1994, 297 (03) : 405 - 416
  • [44] Multichannel calibration technique for optical-fibre chemical sensor using artificial neural network
    Taib, MN
    Narayanaswamy, R
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) : 365 - 370
  • [45] Environmental chemical sensing using quartz microbalance sensor arrays: Application of multicomponent analysis techniques
    Hierlemann, A
    Weimar, U
    Kraus, G
    Gauglitz, G
    Gopel, W
    SENSORS AND MATERIALS, 1995, 7 (03) : 179 - 189
  • [46] Improving semiconductor-based chemical sensor arrays using advanced algorithms for blind source separation
    Bedoya, G
    Jutten, C
    Bermejo, S
    Cabestany, J
    PROCEEDINGS OF THE ISA/IEEE SENSORS FOR INDUSTRY CONFERENCE, 2004, : 149 - 154
  • [47] Differentiation of Complex Vapor Mixtures Using Versatile DNA-Carbon Nanotube Chemical Sensor Arrays
    Kybert, Nicholas J.
    Lerner, Mitchell B.
    Yodh, Jeremy S.
    Preti, George
    Johnson, A. T. Charlie
    ACS NANO, 2013, 7 (03) : 2800 - 2807
  • [48] Removal of Background Drift Nonlinear Interference in 3-D Spectral Arrays for Multi-Way Calibration Using Trilinear Decomposition Methods
    Qing Xiangdong
    Wu Hailong
    Gu Huiwen
    Yin Xiaoli
    Wen Jin
    Shen Xiangzhong
    Yu Ruqin
    ACTA CHIMICA SINICA, 2016, 74 (03) : 277 - 284
  • [49] Self-Calibration direct position determination using a single moving array with sensor gain and phase errors
    Wu, Guizhou
    Zhang, Min
    Guo, Fucheng
    SIGNAL PROCESSING, 2020, 173
  • [50] Sustainable Fabrication and Transfer of High-Precision Nanoparticle Arrays Using Recyclable Chemical Pattern Templates
    Zha, Huaining
    Zhang, Wenjie
    Chen, Peng
    Tao, Jing
    Qiu, Li
    Yang, Fan
    Ye, Shunsheng
    Sang, Yutao
    Nie, Zhihong
    ADVANCED SCIENCE, 2024,