Continuous-Flow Cardiac Assistance: Effects on Aortic Valve Function in a Mock Loop

被引:29
|
作者
Tuzun, Egemen [1 ,2 ,3 ,4 ]
Rutten, Marcel [3 ]
Dat, Marco [3 ]
van de Vosse, Frans [3 ]
Kadipasaoglu, Cihan [1 ,2 ]
de Mol, Bas [3 ,4 ]
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Cardiovasc Res Labs, Houston, TX 77030 USA
[2] St Lukes Episcopal Hosp, Ctr Cardiac Support, Houston, TX 77030 USA
[3] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Cardiovasc Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
left ventricular assist device; continuous flow; aortic valve; mock circulation; LEAFLETS;
D O I
10.1016/j.jss.2010.05.040
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion-with resultant aortic regurgitation-has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. Materials and Methods. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Results. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Conclusions. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 50 条
  • [21] CONTINUOUS-FLOW, VARIABLE MIXING VALVE FOR PERFUSION EXPERIMENTS
    COOK, DL
    HOKANSON, DE
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1976, 367 (02): : 201 - 203
  • [22] INSTANT SHIFT FROM CONTINUOUS-FLOW ASSISTANCE TO PARACORPOREAL DIAPHRAGM TYPE PULSATILE ASSISTANCE
    TAGUCHI, K
    TAKEZAWA, G
    MURASHITA, J
    FUKUNAGA, S
    BURGGER, JP
    ODERMATT, R
    LICHTSTEINER, M
    HAHN, C
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 516 - 519
  • [23] Analysis of Cleveland Clinic continuous-flow total artificial heart performance using the Virtual Mock Loop: Comparison with an in vivo study
    Miyamoto, Takuma
    Horvath, David J.
    Horvath, Dennis W.
    Kuban, Barry D.
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    ARTIFICIAL ORGANS, 2020, 44 (04) : 375 - 383
  • [24] Induced pulsation of a continuous-flow total artificial heart in a mock circulatory system
    Khalil, Hassan A.
    Kerr, Daniel T.
    Schusterman, Mark A., II
    Cohn, William E.
    Frazier, O. H.
    Radovancevic, Branislav
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (05): : 568 - 573
  • [25] Continuous-Flow Left Ventricular Assist Device Support is Associated with Aortic Valve Interstitial Cell Activation
    van Rijswijk, J. W.
    Martina, J. R.
    de Jonge, N.
    de Weger, R. A.
    Vink, A.
    Kluin, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S76 - S76
  • [26] Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device
    Martina, Jerson R.
    Schipper, Marguerite E. I.
    de Jonge, Nicolaas
    Ramjankhan, Faiz
    de Weger, Roel A.
    Lahpor, Jaap R.
    Vink, Aryan
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (04) : 616 - 624
  • [27] Development of de novo aortic valve incompetence in patients with the continuous-flow HeartWare ventricular assist device
    Bhagra, Sai
    Bhagra, Catriona
    Oezalp, Faruk
    Butt, Tanveer
    Ramesh, B. C.
    Parry, Gareth
    Roysam, Chandrika
    Woods, Andrew
    Robinson-Smith, Nicola
    Wrightson, Neil
    MacGowan, Guy A.
    Schueler, Stephan
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (03): : 312 - 319
  • [28] Ten-Year Survival With a Continuous-Flow Left Ventricular Assist Device and Aortic Valve Closure
    Letsou, George, V
    Musfee, Fadi, I
    Lee, Andrew D.
    Cheema, Faisal
    Delgado, Reynolds M.
    Frazier, O. H.
    TEXAS HEART INSTITUTE JOURNAL, 2020, 47 (04) : 325 - 328
  • [29] Aortic Valve Interstitial Cell Activation in Patients with Continuous-Flow Left Ventricular Assist Device Support
    van Rijswijk, Jan Willem
    Martina, Jerson
    de Jonge, Nicolaas
    de Weger, Roel A.
    Vink, Aryan
    Kluin, Jolanda
    CARDIOLOGY, 2014, 128 (02) : 115 - 115
  • [30] Validation of Peripheral Pulse Wave Analysis Technique to Detect Aortic Valve State in Continuous-Flow LVADs
    Singal, Ashish
    Hamel, Aimee
    Larson, Matt
    Kelner, Harrison
    Johnson, Evan
    Eckman, Peter
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2014, 8 (02):