Development of de novo aortic valve incompetence in patients with the continuous-flow HeartWare ventricular assist device

被引:19
|
作者
Bhagra, Sai [1 ]
Bhagra, Catriona [1 ]
Oezalp, Faruk [2 ,3 ]
Butt, Tanveer [2 ,3 ]
Ramesh, B. C. [2 ,3 ]
Parry, Gareth [2 ,3 ]
Roysam, Chandrika [2 ,3 ]
Woods, Andrew [2 ]
Robinson-Smith, Nicola [2 ]
Wrightson, Neil [2 ,3 ]
MacGowan, Guy A. [1 ,2 ,3 ,4 ]
Schueler, Stephan [2 ,3 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[2] Freeman Rd Hosp, Dept Cardiothorac Surg, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[3] Freeman Rd Hosp, Dept Cardiopulmonaty Transplantat, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[4] Newcastle Univ, Inst Genet Med, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
关键词
HVAD; HeartWare; VAD; aortic regurgitation; aortic incompetence; aortic root; echocardiogram; SUPPORTED PATIENTS; INSUFFICIENCY; FUSION; REGURGITATION; IMPLANTATION; FAILURE;
D O I
10.1016/j.healun.2015.10.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: In this study we investigated the development of aortic incompetence (AI) and change in aortic root and left ventricular dimensions after implantation of the continuous-flow HeartWare ventricular assist device (HVAD) in our adult patient cohort. METHODS: A retrospective analysis of serial echocardiograms was performed on patients implanted with an HVAD between July 2009 and July 2013. Data from echocardiograms performed before and at 1 and 2 years (+/- 3 months) were analyzed. Patients with native aortic valves (AoVs) with no previous intervention and HVAD in situ for >= 6 months were included. RESULTS: A total of 73 HVADs in 71 patients with a mean duration of support of 624 +/- 359 days were included in our study. One patient developed moderate AI at 1 year (1.9%). Mild or greater AI was more likely in those with a closed or intermittently opening AoV at 1 year (p = 0.005). Aortic annulus dimensions increased significantly at 1 and 2 years, regardless of extent of AI. At 2 years, in those with mild or worse AI, the sinuses of Valsalva were also larger (p = 0.002). Left ventricular end-diastolic dimension (LVEDD) was significantly reduced in those with no or trace AI at 1 and 2 years (p = 0.012 and p = 0.008, respectively), but remained unchanged in those with AI at both time-points. CONCLUSIONS: The development of more than mild AI is rare in HVAD patients at our center. When encountered, it is more common with a closed AoV. Dilation of the aortic annulus, and root dilation in those with mild or more AI, is seen with HVAD support over time. (C) 2016 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:312 / 319
页数:8
相关论文
共 50 条
  • [1] Development of De-Novo Aortic Valve Incompetence in Patients With the Continuous Flow Heartware® Ventricular Assist Device
    Bhagra, S. K.
    Bhagra, C. J.
    Taylor, M.
    Fazal, I. A.
    Parry, G.
    MacGowan, G.
    Schueler, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S129 - S129
  • [2] De Novo Aortic Regurgitation After Continuous-Flow Left Ventricular Assist Device Implantation
    Patil, Nikhil Prakash
    Sabashnikov, Anton
    Mohite, Prashant N.
    Garcia, Diana
    Weymann, Alexander
    Zych, Bartlomiej
    Bowles, Christopher T.
    Hards, Rachel
    Hedger, Michael
    Popov, Aron F.
    De Robertis, Fabio
    Moza, Ajay
    Bahrami, Toufan
    Amrani, Mohamed
    Rahman-Haley, Shelley
    Banner, Nicholas R.
    Simon, Andre Ruediger
    ANNALS OF THORACIC SURGERY, 2014, 98 (03): : 850 - 857
  • [3] De Novo Aortic Regurgitation After Continuous-Flow Left Ventricular Assist Device Implantation
    Gasparovic, Hrvoje
    Kopjar, Tomislav
    Saeed, Diyar
    Cikes, Maja
    Svetina, Lucija
    Petricevic, Mate
    Lovric, Daniel
    Milicic, Davor
    Biocina, Bojan
    ANNALS OF THORACIC SURGERY, 2017, 104 (02): : 704 - 711
  • [4] Aortic Valve Pathology in Patients Supported by a Continuous-Flow Left Ventricular Assist Device
    Saito, T.
    Potapov, E.
    Wassilew, K.
    Gorodetski, B.
    Krabatsch, T.
    Hetzer, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S195 - S195
  • [5] Aortic valve pathology in patients supported by a continuous-flow left ventricular assist device
    Saito, T.
    Potapov, E.
    Krabatsch, T.
    Gorodetski, B.
    Hetzer, R.
    Wassilew, K.
    VIRCHOWS ARCHIV, 2014, 465 : S9 - S9
  • [6] Aortic Valve Pathology in Patients Supported by Continuous-Flow Left Ventricular Assist Device
    Saito, Tomohiro
    Wassilew, Katharina
    Gorodetski, Boris
    Stein, Julia
    Falk, Volkmar
    Krabatsch, Thomas
    Potapov, Evgenij
    CIRCULATION JOURNAL, 2016, 80 (06) : 1371 - 1377
  • [7] HeartWare continuous-flow ventricular assist device thrombosis: The Bad Oeynhausen experience
    Aissaoui, Nadia
    Boergermann, Jochen
    Gummert, Jan
    Morshuis, Michiel
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (04): : E37 - E39
  • [8] The effect of aortic valve incompetence on the hemodynamics of a continuous flow, ventricular assist device in a mock circulation
    Garcia, Mario A. Zamarripa
    Enriquez, Luz A.
    Dembitsky, Walter
    May-Newman, Karen
    ASAIO JOURNAL, 2008, 54 (03) : 237 - 244
  • [9] Aortic Valve Repair at the Time of Continuous-Flow Left Ventricular Assist Device Implantation
    Melnitchouk, S.
    Takayama, H.
    Jorde, U.
    Uriel, N.
    Colombo, P.
    Yang, J.
    Mancini, D.
    Naka, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S94 - S95
  • [10] Aortic Valve Interstitial Cell Activation in Patients with Continuous-Flow Left Ventricular Assist Device Support
    van Rijswijk, Jan Willem
    Martina, Jerson
    de Jonge, Nicolaas
    de Weger, Roel A.
    Vink, Aryan
    Kluin, Jolanda
    CARDIOLOGY, 2014, 128 (02) : 115 - 115