Development of de novo aortic valve incompetence in patients with the continuous-flow HeartWare ventricular assist device

被引:19
|
作者
Bhagra, Sai [1 ]
Bhagra, Catriona [1 ]
Oezalp, Faruk [2 ,3 ]
Butt, Tanveer [2 ,3 ]
Ramesh, B. C. [2 ,3 ]
Parry, Gareth [2 ,3 ]
Roysam, Chandrika [2 ,3 ]
Woods, Andrew [2 ]
Robinson-Smith, Nicola [2 ]
Wrightson, Neil [2 ,3 ]
MacGowan, Guy A. [1 ,2 ,3 ,4 ]
Schueler, Stephan [2 ,3 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[2] Freeman Rd Hosp, Dept Cardiothorac Surg, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[3] Freeman Rd Hosp, Dept Cardiopulmonaty Transplantat, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[4] Newcastle Univ, Inst Genet Med, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
JOURNAL OF HEART AND LUNG TRANSPLANTATION | 2016年 / 35卷 / 03期
关键词
HVAD; HeartWare; VAD; aortic regurgitation; aortic incompetence; aortic root; echocardiogram; SUPPORTED PATIENTS; INSUFFICIENCY; FUSION; REGURGITATION; IMPLANTATION; FAILURE;
D O I
10.1016/j.healun.2015.10.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: In this study we investigated the development of aortic incompetence (AI) and change in aortic root and left ventricular dimensions after implantation of the continuous-flow HeartWare ventricular assist device (HVAD) in our adult patient cohort. METHODS: A retrospective analysis of serial echocardiograms was performed on patients implanted with an HVAD between July 2009 and July 2013. Data from echocardiograms performed before and at 1 and 2 years (+/- 3 months) were analyzed. Patients with native aortic valves (AoVs) with no previous intervention and HVAD in situ for >= 6 months were included. RESULTS: A total of 73 HVADs in 71 patients with a mean duration of support of 624 +/- 359 days were included in our study. One patient developed moderate AI at 1 year (1.9%). Mild or greater AI was more likely in those with a closed or intermittently opening AoV at 1 year (p = 0.005). Aortic annulus dimensions increased significantly at 1 and 2 years, regardless of extent of AI. At 2 years, in those with mild or worse AI, the sinuses of Valsalva were also larger (p = 0.002). Left ventricular end-diastolic dimension (LVEDD) was significantly reduced in those with no or trace AI at 1 and 2 years (p = 0.012 and p = 0.008, respectively), but remained unchanged in those with AI at both time-points. CONCLUSIONS: The development of more than mild AI is rare in HVAD patients at our center. When encountered, it is more common with a closed AoV. Dilation of the aortic annulus, and root dilation in those with mild or more AI, is seen with HVAD support over time. (C) 2016 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:312 / 319
页数:8
相关论文
共 50 条
  • [31] Progression of aortic regurgitation after continuous-flow left ventricular assist device implantation
    Ertugay, S.
    Kemal, H. S. Hatice Soner
    Balcioglu, O.
    Ozturk, P.
    Engin, C.
    Nalbantgil, S.
    Yagdi, T.
    Ozbaran, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 328 - 328
  • [32] Spontaneous microbubbles in the aortic root and thrombosis of a continuous-flow left ventricular assist device
    Raina, Amresh
    Agarwal, Richa
    Benza, Raymond L.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (05): : 550 - 551
  • [33] Effect of Aortic Valve Opening Pattern on Endothelial Function After Continuous-Flow Left Ventricular Assist Device Implantation
    Kaya, Ersin
    Kocabas, Umut
    Simsek, Evrim
    Nalbantgil, Sanem
    Engin, Cagatay
    Ozbaran, Mustafa
    Akilli, Azem
    ASAIO JOURNAL, 2023, 69 (10) : E429 - E436
  • [34] Factors influencing the functional status of aortic valve in ovine models supported by continuous-flow left ventricular assist device
    Yu, Xin-Yi
    Shi, Jian-Wei
    Zang, Yi-Rui
    Zhang, Jie-Min
    Liu, Zhi-Gang
    ARTIFICIAL ORGANS, 2022, 46 (07) : 1334 - 1345
  • [35] Less Frequency of Aortic Valve Opening and Continuous Flow Device Cause Aortic Regurgitation in Patients With Left Ventricular Assist Device
    Hatano, Masaru
    Kinugawa, Koichiro
    Yao, Atsushi
    Shiga, Taro
    Masukata, Yoko
    Hirata, Yasunobu
    Nishimura, Takashi
    Ono, Minoru
    Kyo, Shunei
    Nagai, Ryozo
    JOURNAL OF CARDIAC FAILURE, 2009, 15 (07) : S170 - S170
  • [36] Impact of aortic valve closure on adverse events and outcomes with the HeartWare ventricular assist device
    Singh, Steve K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01): : 24 - 25
  • [37] PREDICTORS AND IMPACT OF DE NOVO AORTIC REGURGITATION IN PATIENTS WITH CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICES
    Park, Jeong Rang
    Brady, Peter A.
    Clavell, Alfredo
    Maleszewski, Joseph
    Nkomo, Vuyisile
    Pislaru, Sorin
    Stulak, John
    Lin, Grace
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 687 - 687
  • [38] Preoperative higher right ventricular stroke work index increases the risk of de novo aortic insufficiency after continuous-flow left ventricular assist device implantation
    Maeda, Shusaku
    Toda, Koichi
    Shimamura, Kazuo
    Nakamoto, Kei
    Igeta, Masataka
    Sakata, Yasushi
    Sawa, Yoshiki
    Miyagawa, Shigeru
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (03) : 222 - 229
  • [39] Concomitant or late aortic valve intervention and its efficacy for aortic insufficiency associated with continuous-flow left ventricular assist device implantation
    Ando, Masahiko
    Ono, Minoru
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [40] Aortic regurgitation in left ventricular assist device patients - Does aortic root dilatation contribute to valve incompetence?
    Faerber, Gloria
    Schneider, Ulrich
    Graeger, Stephanie
    Elayan, Yousef
    Schwan, Imke
    Tkebuchava, Sophie
    Kirov, Hristo
    Caldonazo, Tulio
    Diab, Mahmoud
    Doenst, Torsten
    ARTIFICIAL ORGANS, 2024,