Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2

被引:1
|
作者
Domnich, Alexander [1 ]
Orsi, Andrea [1 ,2 ]
Panatto, Donatella [2 ]
De Pace, Vanessa [1 ]
Ricucci, Valentina [1 ]
Caligiuri, Patrizia [1 ]
Guarona, Giulia [1 ]
Chessa, Valerio [1 ]
Ferone, Diego [3 ,4 ]
Boccotti, Simona [1 ,2 ]
Bruzzone, Bianca [1 ]
Icardi, Giancarlo [1 ,2 ]
机构
[1] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Hyg Unit, I-16132 Genoa, Italy
[2] Univ Genoa, Dept Hlth Sci, I-16132 Genoa, Italy
[3] Univ Genoa, Dept Internal Med & Med Specialties, I-16132 Genoa, Italy
[4] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Endocrinol Unit, I-16132 Genoa, Italy
来源
PATHOGENS | 2021年 / 10卷 / 12期
基金
欧盟地平线“2020”;
关键词
COVID-19; SARS-CoV-2; RT-LAMP; RT-PCR; diagnostic accuracy; COVID-19;
D O I
10.3390/pathogens10121629
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6-98.9%) and 98.5% (95% CI: 95.7-99.7%), respectively. Inter-assay agreement was almost perfect (kappa = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Development and Application of Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) for Feline Coronavirus Detection
    Techangamsuwan, Somporn
    Radtanakatikanon, Araya
    Thanawongnuwech, Roongroje
    THAI JOURNAL OF VETERINARY MEDICINE, 2013, 43 (02): : 229 - 233
  • [42] Multiplex detection of three banana viruses by reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Zhang, Jingxin
    Borth, Wayne
    Lin, Birun
    Melzer, Michael
    Shen, Huifang
    Pu, Xiaoming
    Sun, Dayuan
    Nelson, Scot
    Hu, John
    TROPICAL PLANT PATHOLOGY, 2018, 43 (06): : 543 - 551
  • [43] Multiplex detection of three banana viruses by reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Jingxin Zhang
    Wayne Borth
    Birun Lin
    Michael Melzer
    Huifang Shen
    Xiaoming Pu
    Dayuan Sun
    Scot Nelson
    John Hu
    Tropical Plant Pathology, 2018, 43 : 543 - 551
  • [44] Performance of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Targeting the RNA Polymerase Gene for the Direct Detection of SARS-CoV2 in Nasopharyngeal Swabs
    Hoffmann, Elias da Rosa
    Balzan, Lisiane da Rocha
    Inamine, Everton
    Pancotto, Lisiane Rech
    Gaboardi, Guilherme
    Cantarelli, Vlademir Vicente
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (17)
  • [45] Detection of Novel duck reovirus (NDRV) using visual reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Li, Zhili
    Cai, Yuejia
    Liang, Guozhi
    El-Ashram, Saeed
    Mei, Minmin
    Huang, Wenjing
    Li, Xiaowen
    Li, Wenfeng
    He, Cheng
    Huang, Shujian
    SCIENTIFIC REPORTS, 2018, 8
  • [46] Detection of Novel duck reovirus (NDRV) using visual reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Zhili Li
    Yuejia Cai
    Guozhi Liang
    Saeed El-Ashram
    Minmin Mei
    Wenjing Huang
    Xiaowen Li
    Wenfeng Li
    Cheng He
    Shujian Huang
    Scientific Reports, 8
  • [47] Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2
    Lau, Yee Ling
    Ismail, Ilyiana
    Mustapa, Nur Izati
    Lai, Meng Yee
    Soh, Tuan Suhaila Tuan
    Hassan, Afifah
    Peariasamy, Kalaiarasu M.
    Lee, Yee Leng
    Chong, Yoong Min
    Sam, I-Ching
    Goh, Pik Pin
    PEERJ, 2020, 8
  • [48] Comparative evaluation of 19 reverse transcription loop-mediated isothermal amplification assays for detection of SARS-CoV-2
    Dong, Yajuan
    Wu, Xiuming
    Li, Shenwei
    Lu, Renfei
    Li, Yingxue
    Wan, Zhenzhou
    Qin, Jianru
    Yu, Guoying
    Jin, Xia
    Zhang, Chiyu
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [49] Comparative evaluation of 19 reverse transcription loop-mediated isothermal amplification assays for detection of SARS-CoV-2
    Yajuan Dong
    Xiuming Wu
    Shenwei Li
    Renfei Lu
    Yingxue Li
    Zhenzhou Wan
    Jianru Qin
    Guoying Yu
    Xia Jin
    Chiyu Zhang
    Scientific Reports, 11
  • [50] Rapid detection of Banna virus by reverse transcription-loop -mediated isothermal amplification (RT-LAMP)
    Xia, Han
    Zhao, Na
    Zhao, Lu
    Wang, Yujuan
    Zhao, Wang
    Yuan, Zhiming
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2019, 78 : 93 - 98