Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2

被引:1
|
作者
Domnich, Alexander [1 ]
Orsi, Andrea [1 ,2 ]
Panatto, Donatella [2 ]
De Pace, Vanessa [1 ]
Ricucci, Valentina [1 ]
Caligiuri, Patrizia [1 ]
Guarona, Giulia [1 ]
Chessa, Valerio [1 ]
Ferone, Diego [3 ,4 ]
Boccotti, Simona [1 ,2 ]
Bruzzone, Bianca [1 ]
Icardi, Giancarlo [1 ,2 ]
机构
[1] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Hyg Unit, I-16132 Genoa, Italy
[2] Univ Genoa, Dept Hlth Sci, I-16132 Genoa, Italy
[3] Univ Genoa, Dept Internal Med & Med Specialties, I-16132 Genoa, Italy
[4] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Endocrinol Unit, I-16132 Genoa, Italy
来源
PATHOGENS | 2021年 / 10卷 / 12期
基金
欧盟地平线“2020”;
关键词
COVID-19; SARS-CoV-2; RT-LAMP; RT-PCR; diagnostic accuracy; COVID-19;
D O I
10.3390/pathogens10121629
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6-98.9%) and 98.5% (95% CI: 95.7-99.7%), respectively. Inter-assay agreement was almost perfect (kappa = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using Reverse Transcribed Loop-Mediated Isothermal Amplification (RT-LAMP)
    Naddaf, Rawi
    Ben-Assa, Nadav
    Gefen, Tal
    Capucha, Tal
    Hajjo, Haitham
    Mandelbaum, Noa
    Elbaum, Lilach
    Kaplan, Shai
    Rotem, Assaf
    Chowers, Michal
    Szwarcwort-Cohen, Moran
    Paul, Mical
    Geva-Zatorsky, Naama
    BIO-PROTOCOL, 2020, 10 (20):
  • [32] RNA purification-free detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP) (vol 50, 2, 2022)
    Lai, Meng Yee
    Suppiah, Jeyanthi
    Thayan, Ravindran
    Ismail, Ilyiana
    Mustapa, Nur Izati
    Soh, Tuan Suhaila Tuan
    Hassan, Affah Haji
    Peariasamy, Kalaiarasu M.
    Lee, Yee Leng
    Lau, Yee Ling
    TROPICAL MEDICINE AND HEALTH, 2023, 51 (01)
  • [33] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) for point-of-care detection of SARS-CoV-2: a clinical study to evaluate agreement with RT-qPCR
    Natoli, Mary
    Kundrod, Kathryn
    Chang, Megan
    Smith, Chelsey
    Paul, Sai
    Eldin, Karen
    Patel, Keyur
    Baker, Ellen
    Schmeler, Kathleen
    Richards-Kortum, Rebecca
    LANCET GLOBAL HEALTH, 2021, 9 : 3 - 3
  • [34] Rapid Detection of Foot-and-Mouth Disease Virus by Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP)
    Shao, Jun-Jun
    Chang, Hui-Yun
    Zhou, Guang-Qing
    Cong, Guo-Zheng
    Du, Jun-Zheng
    Lin, Tong
    Gao, Shan-Dian
    He, Ji-Jun
    Liu, Xiang-Tao
    Liu, Ji-Xing
    Gao, Jin-Liang
    INTERNATIONAL JOURNAL OF APPLIED RESEARCH IN VETERINARY MEDICINE, 2010, 8 (02): : 133 - 142
  • [35] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of viral hemorrhagic septicaemia virus (VHS)
    Soliman, H.
    El-Matbouli, M.
    VETERINARY MICROBIOLOGY, 2006, 114 (3-4) : 205 - 213
  • [36] A Bioengineered Positive Control for Rapid Detection of the Ebola Virus by Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP)
    Lam, Patricia
    Keri, Ruth A.
    Steinmetz, Nicole F.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2017, 3 (03): : 452 - 459
  • [37] Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Specific and Rapid Detection of Tilapia Lake Virus
    Phusantisampan, Theerawut
    Rawiwan, Pattarasuda
    Roy, Sri Rajiv Kumar
    Sriariyanun, Malinee
    Surachetpong, Win
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [38] Improved Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for the Rapid and Sensitive Detection of Yam mosaic virus
    Festus, Ruth O.
    Seal, Susan E.
    Prempeh, Ruth
    Quain, Marian D.
    Silva, Goncalo
    VIRUSES-BASEL, 2023, 15 (07):
  • [39] Rapid and efficient detection of mycoplasma pneumonia RNA by reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Ma, Cuiping
    Yan, Chunyu
    Shi, Chao
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [40] An inexpensive and rapid diagnostic method for detection of SARS-CoV-2 RNA by loop-mediated isothermal amplification (LAMP)
    Prakash, S.
    Priyatma
    Aasarey, R.
    Pandey, P. K.
    Mathur, P.
    Arulselvi, S.
    METHODSX, 2023, 10