Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2

被引:1
|
作者
Domnich, Alexander [1 ]
Orsi, Andrea [1 ,2 ]
Panatto, Donatella [2 ]
De Pace, Vanessa [1 ]
Ricucci, Valentina [1 ]
Caligiuri, Patrizia [1 ]
Guarona, Giulia [1 ]
Chessa, Valerio [1 ]
Ferone, Diego [3 ,4 ]
Boccotti, Simona [1 ,2 ]
Bruzzone, Bianca [1 ]
Icardi, Giancarlo [1 ,2 ]
机构
[1] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Hyg Unit, I-16132 Genoa, Italy
[2] Univ Genoa, Dept Hlth Sci, I-16132 Genoa, Italy
[3] Univ Genoa, Dept Internal Med & Med Specialties, I-16132 Genoa, Italy
[4] San Martino Policlin Hosp, IRCCS Oncol & Neurosci, Endocrinol Unit, I-16132 Genoa, Italy
来源
PATHOGENS | 2021年 / 10卷 / 12期
基金
欧盟地平线“2020”;
关键词
COVID-19; SARS-CoV-2; RT-LAMP; RT-PCR; diagnostic accuracy; COVID-19;
D O I
10.3390/pathogens10121629
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6-98.9%) and 98.5% (95% CI: 95.7-99.7%), respectively. Inter-assay agreement was almost perfect (kappa = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Meng Yee Lai
    Fatma Diyana Mohd Bukhari
    Nur Zulaikha Zulkefli
    Ilyiana Ismail
    Nur Izati Mustapa
    Tuan Suhaila Tuan Soh
    Afifah Haji Hassan
    Kalaiarasu M. Peariasamy
    Yee Leng Lee
    Jeyanthi Suppiah
    Ravindran Thayan
    Mohd Khairi Mat Isa
    Nur Zafirah Abdul Wahid
    Yee Ling Lau
    [J]. BMC Infectious Diseases, 22
  • [22] Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting
    Nuchnoi, Pornlada
    Piromtong, Pakorn
    Siribal, Saranya
    Anansilp, Korrarit
    Thichanpiang, Peeradech
    Okada, Pilailuk Akkapaiboon
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2023, 128 : 285 - 289
  • [23] Analysis of a Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) for yellow fever diagnostic
    Nunes, Marcio R. T.
    Vianez, Joau Lidio, Jr.
    Nunes, Keley N. B.
    da Silva, Sandro Patroca
    Lima, Clayton P. S.
    Guzman, Hilda
    Martins, Livia C.
    Carvalho, Valeria L.
    Tesh, Robert B.
    Vasconcelos, Pedro F. C.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2015, 226 : 40 - 51
  • [24] Development of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Renfei Lu
    Xiuming Wu
    Zhenzhou Wan
    Yingxue Li
    Lulu Zuo
    Jianru Qin
    Xia Jin
    Chiyu Zhang
    [J]. Virologica Sinica, 2020, (03) : 344 - 347
  • [25] Development of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Lu, Renfei
    Wu, Xiuming
    Wan, Zhenzhou
    Li, Yingxue
    Zuo, Lulu
    Qin, Jianru
    Jin, Xia
    Zhang, Chiyu
    [J]. VIROLOGICA SINICA, 2020, 35 (03) : 344 - 347
  • [26] Development of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Renfei Lu
    Xiuming Wu
    Zhenzhou Wan
    Yingxue Li
    Lulu Zuo
    Jianru Qin
    Xia Jin
    Chiyu Zhang
    [J]. Virologica Sinica., 2020, 35 (03) - 347
  • [27] Rapid and sensitive detection of porcine torovirus by a reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Liu, Xiaowan
    Zhou, Yuancheng
    Yang, Fan
    Liu, Pengjuan
    Cai, Yuhan
    Huang, Jianbo
    Zhu, Ling
    Xu, Zhiwen
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2016, 228 : 103 - 107
  • [28] Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP)
    Curtis, Kelly A.
    Rudolph, Donna L.
    Owen, S. Michele
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2008, 151 (02) : 264 - 270
  • [29] Detection of enterovirus 71 using reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Wang, Xiang
    Zhu, Jun-ping
    Zhang, Qian
    Xu, Zi-gang
    Zhang, Fang
    Zhao, Zhi-hui
    Zheng, Wen-zhi
    Zheng, Li-shu
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2012, 179 (02) : 330 - 334
  • [30] Detection of human Enterovirus 71 reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Yaqing, H.
    Wenping, Z.
    Zhiyi, Y.
    Xionghu, W.
    Shouyi, Y.
    Hong, Y.
    Yingchun, D.
    Guifang, H.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2012, 54 (03) : 233 - 239