Novel 16-Channel Receive Coil Array for Accelerated Upper Airway MRI at 3 Tesla

被引:17
|
作者
Kim, Yoon-Chul [1 ]
Hayes, Cecil E. [2 ]
Narayanan, Shrikanth S. [1 ]
Nayak, Krishna S. [1 ]
机构
[1] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA 90089 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
upper airway MRI; RF coil design; parallel imaging; rapid imaging; OBSTRUCTIVE SLEEP-APNEA; ARBITRARY K-SPACE; RECONSTRUCTION; TRAJECTORIES; SENSE;
D O I
10.1002/mrm.22742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Upper airway MRI can provide a noninvasive assessment of speech and swallowing disorders and sleep apnea. Recent work has demonstrated the value of high-resolution three-dimensional imaging and dynamic two-dimensional imaging and the importance of further improvements in spatio-temporal resolution. The purpose of the study was to describe a novel 16-channel 3 Tesla receive coil that is highly sensitive to the human upper airway and investigate the performance of accelerated upper airway MRI with the coil. In three-dimensional imaging of the upper airway during static posture, 6-fold acceleration is demonstrated using parallel imaging, potentially leading to capturing a whole three-dimensional vocal tract with 1.25 mm isotropic resolution within 9 sec of sustained sound production. Midsagittal spiral parallel imaging of vocal tract dynamics during natural speech production is demonstrated with 2 x 2 mm(2) in-plane spatial and 84 ms temporal resolution. Magn Reson Med 65:1711-1717, 2011. (C)2010 Wiley-Liss, Inc.
引用
收藏
页码:1711 / 1717
页数:7
相关论文
共 50 条
  • [1] A flexible 16-channel custom coil array for accelerated imaging of upper and infraglottic airway at 3 T
    Alam, Wahidul
    Reineke, Scott
    Viswanath, Madavan Raja
    Rusho, Rushdi Zahid
    Van Daele, Douglas
    Meyer, David
    Liu, Junjie
    Lingala, Sajan Goud
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (05) : 2117 - 2130
  • [2] A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla
    May, Markus W.
    Hansen, Sam-Luca J. D.
    Mahmutovic, Mirsad
    Scholz, Alina
    Kutscha, Nicolas
    Guerin, Bastien
    Stockmann, Jason P.
    Barry, Robert L.
    Kazemivalipour, Ehsan
    Gumbrecht, Rene
    Kimmlingen, Ralph
    Adriany, Markus
    Chang, Yulin
    Triantafyllou, Christina
    Knake, Susanne
    Wald, Lawrence L.
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (03) : 1419 - 1433
  • [3] Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla
    de Zwart, JA
    Ledden, PJ
    van Gelderen, P
    Bodurka, J
    Chu, RX
    Duyn, JH
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 22 - 26
  • [4] A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 tesla
    Schmitt, Melanie
    Potthast, Andreas
    Sosnovik, David E.
    Polimeni, Jonathan R.
    Wiggins, Graham C.
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1431 - 1439
  • [5] Optimization and Simulation of a 16-Channel Loop and Dipole Array for Head MRI Applications at 10.5 Tesla
    Radder, Jerahmie
    Woo, Myung-Kyun
    Van de Moortele, Pierre-Francois
    Metzger, Greg
    Ertuerk, Arcan
    Strupp, John
    Ugurbil, Kamil
    Adriany, Gregor
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1828 - 1831
  • [6] A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI
    Erturk, M. Arcan
    Raaijmakers, Alexander J. E.
    Adriany, Gregor
    Ugurbil, Kamil
    Metzger, Gregory J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 884 - 894
  • [7] Closely Fitted 16-Channel Breast Array for MRI
    Narongrit, Folk W.
    Ramesh, Thejas Vishnu
    Rispoli, Joseph V.
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 40 - 42
  • [8] A Four-Channel Broadband MRI Receive Array Coil
    Hou, Jue
    Bauer, Courtney C.
    Sun, Chenhao
    Malone, Ben
    Griffin, Jay
    Wright, Steven M.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [9] USING 3 TESLA MRI WITH A HIGH-RESOLUTION 16-CHANNEL HAND COIL TO DIFFERENTIATE BETWEEN RHEUMATOID AND PSORIATIC ARTHRITIS: A PILOT STUDY
    Sewerin, P.
    Abrar, D.
    Lautwein, A.
    Vordenbaeumen, S.
    Brinks, R.
    Goertz, C.
    Frenken, M.
    Schneider, M.
    Ostendorf, B.
    Schleich, C.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 1408 - 1409
  • [10] A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla
    Adriany, Gregor
    De Moortele, Pierre-Francois Van
    Ritter, Johannes
    Moeller, Steen
    Auerbach, Edward J.
    Akguen, Can
    Snyder, Carl J.
    Vaughan, Thomas
    Ugurbill, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 590 - 597