Closely Fitted 16-Channel Breast Array for MRI

被引:1
|
作者
Narongrit, Folk W. [1 ]
Ramesh, Thejas Vishnu [2 ]
Rispoli, Joseph V. [1 ,3 ]
机构
[1] Purdue Univ, Elmore Family Sch Elect & Comp Engn, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[3] Univ Virginia, Radiol & Med Imaging, Charlottesville, VA USA
关键词
MRI; RF Coils; Signal-to-Noise Ratio; Breast Imaging;
D O I
10.1109/IMBIOC56839.2023.10304880
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: We propose a 16-channel bilateral breast coil array prototype for high-resolution MR imaging at 3T. This coil aims to improve signal-to-noise ratio (SNR) by positioning the coil array close to the breast. Methods: Sixteen 80-mm coil elements made on flexible printed circuit boards were placed on top of a 3D-printed plastic housing modeled to fit most cup sizes. Match, tune, and detune elements were incorporated onto the coil. Phantom and in-vivo scans were performed to demonstrate the SNR profile and clinical efficacy of the coil. Conclusion: The in-vivo images show high sensitivity and coverage of the breast, and the SNR profile evaluated from the phantom images was relatively uniform throughout the imaging volume.
引用
收藏
页码:40 / 42
页数:3
相关论文
共 50 条
  • [1] An Open Source 16-Channel Breast Array for Prone and Supine MRI
    Narongrit, Folk W.
    Ramesh, Thejas Vishnu
    Rispoli, Joseph V.
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024, 8 (03): : 251 - 258
  • [2] Custom-Fitted 16-Channel Bilateral Breast Coil for Bidirectional Parallel Imaging
    Nnewihe, Anderson N.
    Grafendorfer, Thomas
    Daniel, Bruce L.
    Calderon, Paul
    Alley, Marcus T.
    Robb, Fraser
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 281 - 289
  • [3] A MONOLITHIC 16-CHANNEL ANALOG ARRAY NORMALIZER
    GILBERT, B
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1984, 19 (06) : 956 - 963
  • [4] A 16-CHANNEL CMOS NEURAL STIMULATING ARRAY
    TANGHE, SJ
    WISE, KD
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1992, 27 (12) : 1819 - 1825
  • [5] Optimization and Simulation of a 16-Channel Loop and Dipole Array for Head MRI Applications at 10.5 Tesla
    Radder, Jerahmie
    Woo, Myung-Kyun
    Van de Moortele, Pierre-Francois
    Metzger, Greg
    Ertuerk, Arcan
    Strupp, John
    Ugurbil, Kamil
    Adriany, Gregor
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1828 - 1831
  • [6] Novel 16-Channel Receive Coil Array for Accelerated Upper Airway MRI at 3 Tesla
    Kim, Yoon-Chul
    Hayes, Cecil E.
    Narayanan, Shrikanth S.
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1711 - 1717
  • [7] A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI
    Erturk, M. Arcan
    Raaijmakers, Alexander J. E.
    Adriany, Gregor
    Ugurbil, Kamil
    Metzger, Gregory J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 884 - 894
  • [8] 16-CHANNEL COMMUTATOR
    IVANOV, YI
    POTOTSKAYA, IV
    GONCHARENKO, LF
    DUSHKIN, AA
    MEASUREMENT TECHNIQUES USSR, 1982, 25 (09): : 750 - 753
  • [9] A 16-Channel Dense Array for In Vivo Animal Cortical MRI/fMRI on 7T Human Scanners
    Zhang, Xiaotong
    Zhang, Jialu
    Gao, Yang
    Qian, Meizhen
    Qu, Shuxian
    Quan, Zhiyan
    Yu, Miao
    Chen, Xiaoming
    Wang, Yueming
    Pan, Gang
    Adriany, Gregor
    Roe, Anna Wang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (05) : 1611 - 1618
  • [10] 16-channel flexible optical passband filter array for CDCF ROADM
    Yuan, Zhilin
    Li, Wei
    Yang, Rui
    Yang, Liu
    Wang, Fan
    Guo, Jinping
    Xu, Zuowei
    Feng, Qiguang
    Wang, You
    Hu, Qianggao
    OPTICS COMMUNICATIONS, 2019, 450 : 61 - 66