Closely Fitted 16-Channel Breast Array for MRI

被引:1
|
作者
Narongrit, Folk W. [1 ]
Ramesh, Thejas Vishnu [2 ]
Rispoli, Joseph V. [1 ,3 ]
机构
[1] Purdue Univ, Elmore Family Sch Elect & Comp Engn, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[3] Univ Virginia, Radiol & Med Imaging, Charlottesville, VA USA
关键词
MRI; RF Coils; Signal-to-Noise Ratio; Breast Imaging;
D O I
10.1109/IMBIOC56839.2023.10304880
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: We propose a 16-channel bilateral breast coil array prototype for high-resolution MR imaging at 3T. This coil aims to improve signal-to-noise ratio (SNR) by positioning the coil array close to the breast. Methods: Sixteen 80-mm coil elements made on flexible printed circuit boards were placed on top of a 3D-printed plastic housing modeled to fit most cup sizes. Match, tune, and detune elements were incorporated onto the coil. Phantom and in-vivo scans were performed to demonstrate the SNR profile and clinical efficacy of the coil. Conclusion: The in-vivo images show high sensitivity and coverage of the breast, and the SNR profile evaluated from the phantom images was relatively uniform throughout the imaging volume.
引用
收藏
页码:40 / 42
页数:3
相关论文
共 50 条
  • [31] 16-CHANNEL PARALLEL OPTICAL INTERCONNECT DEMONSTRATION WITH AN INGAAS/INP MQW MODULATOR ARRAY
    BARNES, N
    HEALEY, P
    REJMANGREENE, MAZ
    SCOTT, EG
    WEBB, RP
    ELECTRONICS LETTERS, 1990, 26 (15) : 1126 - 1127
  • [32] A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer
    Isabel Dregely
    Titus Lanz
    Stephan Metz
    Matthias F. Mueller
    Marika Kuschan
    Manoj Nimbalkar
    Ralph A. Bundschuh
    Sibylle I. Ziegler
    Axel Haase
    Stephan G. Nekolla
    Markus Schwaiger
    European Radiology, 2015, 25 : 1154 - 1161
  • [33] 6-CHANNEL AND 16-CHANNEL ANALYSIS OF EEG
    FARKAS, I
    DESI, I
    STROHMAYER, A
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 50 (3-4): : P96 - P96
  • [34] Evaluation of improved CT-based hardware attenuation correction in PET/MRI: Application to a 16-channel RF breast coil
    Lindemann, Maike E.
    Oehmigen, Mark
    Lanz, Titus
    Grafe, Hong
    Bruckmann, Nils Martin
    Umutlu, Lale
    Quick, Harald H.
    MEDICAL PHYSICS, 2022, 49 (04) : 2279 - 2294
  • [35] A 16-channel loop array for in vivo macaque whole-brain imaging at 7 T
    Lou, Feiyang
    Tang, Xiaocui
    Quan, Zhiyan
    Qian, Meizhen
    Wang, Jianbao
    Qu, Shuxian
    Gao, Yang
    Wang, Yueming
    Pan, Gang
    Lai, Hsin-Yi
    Roe, Anna Wang
    Zhang, Xiaotong
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 179 - 183
  • [36] A 16-channel loop array for in vivo macaque whole-brain imaging at 3 T
    Quan, Zhiyan
    Gao, Yang
    Qu, Shuxian
    Wang, Xiaojie
    Friedman, Robert M.
    Chernov, Mykyta M.
    Kroenke, Christopher D.
    Roe, Anna Wang
    Zhang, Xiaotong
    MAGNETIC RESONANCE IMAGING, 2020, 68 : 167 - 172
  • [37] A 16-Channel Dipole Antenna Array for Human Head Magnetic Resonance Imaging at 10.5 Tesla
    Woo, Myung Kyun
    DelaBarre, Lance
    Waks, Matt
    Radder, Jerahmie
    Choi, Uk-Su
    Lagore, Russell
    Ugurbil, Kamil
    Adriany, Gregor
    SENSORS, 2021, 21 (21)
  • [38] 16-Channel Organic Electrochemical Transistor Array for In Vitro Conduction Mapping of Cardiac Action Potential
    Gu, Xi
    Yao, Chunlei
    Liu, Ying
    Hsing, I-Ming
    ADVANCED HEALTHCARE MATERIALS, 2016, 5 (18) : 2345 - 2351
  • [39] Reconstruction of gas-liquid flows using the stochastic estimation with a 16-channel electrode array
    Zhou, Wei
    Suzuki, Takao
    Nishiumi, Toyohiko
    Yamamoto, Fujio
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (10)
  • [40] Staging of gastric cancer with 16-channel MDCT
    C.-Y. Chen
    D.-C. Wu
    W.-Y. Kang
    J.-S. Hsu
    Abdominal Imaging, 2006, 31 : 514 - 520