Comparative behavior of glucose oxidase and oxalate oxidase immobilized in mucin/chitosan hydrogels for biosensors applications

被引:12
|
作者
Benavidez, Tomas E. [1 ]
Baruzzi, Ana M. [1 ]
机构
[1] Univ Nacl Cordoba, INFIQC CONICET, Dept Fis Quim, Fac Ciencias Quim, RA-5016 Cordoba, Argentina
关键词
Biosensor; Enzymes; Hydrogel; CHITOSAN MEMBRANES; SOLUTE DIFFUSION; DRUG-DELIVERY; CROSS-LINKING; RELEASE; ENZYME; BIOMATERIALS; MECHANISMS; TRANSPORT; NETWORKS;
D O I
10.1016/j.polymer.2011.12.014
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The analytical response of amperometric glucose electrodes was explained in the framework of the properties of hydrogels with different muc/chit ratio at pH = 7.00 used as immobilization matrix for glucose oxidase. The continuous increase in the sensitivity of the electrodes with the amount of chitosan was attributed to a more efficient crosslinking without affecting the enzyme activity. The results were compared with those obtained using the same matrices to immobilize Oxalate Oxidase at pH = 2.85 where it has the highest activity. A maximum sensitivity at muc/chit 70/30 ratio for these oxalate electrodes was observed. Decrease in permeability of negatively charged oxalate with the chitosan content in the matrices, in spite of the high partition coefficient, explains the analytical differences with glucose electrodes. Swelling and viscoelasticity of the hydrogels allowed to asses the importance of a hydrophilic environment for the enzyme in both cases. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:438 / 444
页数:7
相关论文
共 50 条
  • [41] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [42] Study of Microfluidic Chip with In-situ Prepared Chitosan Membrane Immobilized with Glucose Oxidase
    Cao Qiang
    Xu Yi
    Song Defu
    Han Weiwei
    Dong Xizhe
    MICRO AND NANO TECHNOLOGY: 1ST INTERNATIONAL CONFERENCE OF CHINESE SOCIETY OF MICRO/NANO TECHNOLOGY(CSMNT), 2009, 60-61 : 194 - 197
  • [43] Highly stable biosensor based on glucose oxidase immobilized in chitosan film for diagnosis of diabetes
    Zare, Hossein
    Najafpour, Ghasem D.
    Jahanshahi, Mohsen
    Rahimnejad, Mostafa
    Rezvani, Mohsen
    ROMANIAN BIOTECHNOLOGICAL LETTERS, 2017, 22 (03): : 12611 - 12619
  • [44] DETERMINATION OF URINARY OXALATE USING BANANA OXALATE OXIDASE - COMPARISON WITH IMMOBILIZED ENZYME
    LATHIKA, KM
    INAMDAR, KV
    TARACHAND, U
    SINGH, BB
    RAGHAVAN, KG
    ANALYTICAL LETTERS, 1995, 28 (03) : 425 - 442
  • [45] Determination of urinary oxalate with oxalate oxidase and peroxidase immobilized onto glass beads
    Pundir, CS
    Kuchhal, NK
    Bhargava, AK
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 1998, 27 : 103 - 107
  • [46] Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on Prussian blue layer
    Zhu, JH
    Zhu, ZQ
    Lai, ZS
    Wang, R
    Guo, XM
    Wu, XQ
    Zhang, GX
    Zhang, ZR
    Zhang, ZR
    Wang, YT
    Chen, ZY
    SENSORS, 2002, 2 (04): : 127 - 136
  • [47] CONTINUOUS-FLOW ASSAY FOR URINARY OXALATE USING IMMOBILIZED OXALATE OXIDASE
    KASIDAS, GP
    ROSE, GA
    ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (JUL) : 412 - 419
  • [48] ENZYME ELECTRODE BASED ON OXALATE OXIDASE IMMOBILIZED IN GELATIN FOR SPECIFIC DETERMINATION OF OXALATE
    DINCKAYA, E
    TELEFONCU, A
    INDIAN JOURNAL OF BIOCHEMISTRY & BIOPHYSICS, 1993, 30 (05): : 282 - 284
  • [49] Electrodeposited glucose oxidase/anionic clay for glucose biosensors design
    Mignani, Adriana
    Scavetta, Erika
    Tonelli, Domenica
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 98 - 106
  • [50] OXALATE MEASURED BY AN OXALATE-OXIDASE ELECTRODE IMMOBILIZED ON A COLLAGEN-MEMBRANE
    AMINI, MAS
    VALLON, JJ
    BICHON, C
    ANALYTICAL LETTERS, 1989, 22 (01) : 43 - 59