Comparative behavior of glucose oxidase and oxalate oxidase immobilized in mucin/chitosan hydrogels for biosensors applications

被引:12
|
作者
Benavidez, Tomas E. [1 ]
Baruzzi, Ana M. [1 ]
机构
[1] Univ Nacl Cordoba, INFIQC CONICET, Dept Fis Quim, Fac Ciencias Quim, RA-5016 Cordoba, Argentina
关键词
Biosensor; Enzymes; Hydrogel; CHITOSAN MEMBRANES; SOLUTE DIFFUSION; DRUG-DELIVERY; CROSS-LINKING; RELEASE; ENZYME; BIOMATERIALS; MECHANISMS; TRANSPORT; NETWORKS;
D O I
10.1016/j.polymer.2011.12.014
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The analytical response of amperometric glucose electrodes was explained in the framework of the properties of hydrogels with different muc/chit ratio at pH = 7.00 used as immobilization matrix for glucose oxidase. The continuous increase in the sensitivity of the electrodes with the amount of chitosan was attributed to a more efficient crosslinking without affecting the enzyme activity. The results were compared with those obtained using the same matrices to immobilize Oxalate Oxidase at pH = 2.85 where it has the highest activity. A maximum sensitivity at muc/chit 70/30 ratio for these oxalate electrodes was observed. Decrease in permeability of negatively charged oxalate with the chitosan content in the matrices, in spite of the high partition coefficient, explains the analytical differences with glucose electrodes. Swelling and viscoelasticity of the hydrogels allowed to asses the importance of a hydrophilic environment for the enzyme in both cases. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:438 / 444
页数:7
相关论文
共 50 条
  • [31] Evaluation of Oxalate Decarboxylase and Oxalate Oxidase for Industrial Applications
    Pierre Cassland
    Anders Sjöde
    Sandra Winestrand
    Leif J. Jönsson
    Nils-Olof Nilvebrant
    Applied Biochemistry and Biotechnology, 2010, 161 : 255 - 263
  • [32] Evaluation of Oxalate Decarboxylase and Oxalate Oxidase for Industrial Applications
    Cassland, Pierre
    Sjode, Anders
    Winestrand, Sandra
    Jonsson, Leif J.
    Nilvebrant, Nils-Olof
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2010, 161 (1-8) : 255 - 263
  • [33] Iridium oxide|glucose oxidase biosensors and microprobes
    Rauh, RD
    Twardoch, UM
    Jones, GS
    Jones, RB
    PROCEEDINGS OF THE SYMPOSIUM ON MOLECULAR FUNCTIONS OF ELECTROACTIVE THIN FILMS, 1999, 98 (26): : 176 - 183
  • [34] GLUCOSE OXIDASE - VANADIUM SUBSTITUTED ANIONIC CLAY AS BIONANOCOMPOSITE FORMULATIONS FOR BIOSENSORS APPLICATIONS
    Carja, Gabriela
    Ratoi, Simona
    Ciobanu, Gabriela
    Balasanian, Ion
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2009, 8 (01): : 55 - 58
  • [35] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [36] DETECTION OF GLUCOSE BY USING IMMOBILIZED GLUCOSE-OXIDASE
    MANOCHIOPINIJ, S
    SAPSAMARNWONG, C
    SIRISALI, K
    JOURNAL OF THE SCIENCE SOCIETY OF THAILAND, 1985, 11 (02): : 79 - 91
  • [37] GLUCOSE-OXIDASE IMMOBILIZED WITH POLYURETHANE FOR GLUCOSE SENSING
    PHADKE, RS
    ALVA, S
    GOVIL, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 147 - BIOT
  • [38] EVALUATION OF A PROCEDURE FOR GLUCOSE UTILIZING IMMOBILIZED GLUCOSE OXIDASE
    BROWN, HH
    MEOLA, JM
    SANSUR, M
    LEON, LP
    CLINICAL CHEMISTRY, 1975, 21 (07) : 978 - 978
  • [39] A METHOD FOR MEASURING GLUCOSE OXIDASE-IMMOBILIZED GLUCOSE
    IVANOV, IP
    DANEV, SI
    DIMITROV, DG
    LABORATORNOE DELO, 1991, (10): : 28 - 30
  • [40] IMMOBILIZED GLUCOSE OXIDASE USED TO MEASURE GLUCOSE IN SERUM
    KUNZ, HJ
    STASTNY, M
    CLINICAL CHEMISTRY, 1974, 20 (08) : 1018 - 1022