Five-Year Performance of an ESE Lightning Protection System for a Large Scale PV Power Plant in Thailand

被引:1
|
作者
Kongnok, Rungphet [1 ]
Pummaitong, Thanakorn [1 ]
Plangklang, Boonyang [1 ]
机构
[1] Rajamangala Univ Technol Thanyaburi, Dept Elect Engn, Fac Engn, 39 Moo 1,Klong 6, Khlong Luang 12110, Pathum Thani, Thailand
来源
SYMMETRY-BASEL | 2021年 / 13卷 / 11期
关键词
Franklin lightning protection; ESE lightning protection; PV power plant; STROKE;
D O I
10.3390/sym13112106
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This article presents a five-year performance review of an early streamer emission (ESE) air terminal lightning protection system for a large scale PV power plant in Thailand. The comparison effect of a Franklin lightning protection system and the ESE lightning protection system was analyzed for the PV power plant. The ESE lightning protection system was selected to be implemented in the PV power plant. The capacity of the PV power plant studied was 8 MWp on an area of 150,000 square meters in the Nong Ya Plong district, Phetchaburi province, Western Thailand. A Franklin lightning rod type was also designed to be implemented in this PV power plant. The Franklin lightning rod type comprised 122 pieces but the ESE lightning rod type consisted of only 11 pieces. The conceptual design of the Franklin rod type followed the standard of the Council of Engineers, Thailand, and the ESE lightning rod type followed the NFC17102 standard of France. The estimated cost of installation was a key comparison to select the lightning protection system; the total installation cost of the Franklin lightning rod type was USD 197,363.80 and the ESE lightning rod type was USD 44,338.06. The lightning system was applied to the lightning arrester in the power plant to provide good protection, in which the balance of the pole to the mounting position is required to optimize the system performance. The result of the simulation also showed that the shading effects of the Franklin rod type were greater than the ESE rod type. The installation cost of the Franklin lightning rod type was 4.45 times more expensive than the ESE lightning rod type. Therefore, the ESE lightning protection system was selected to be implemented in the PV power plant. From the recorded data of the five-year performance of the ESE lightning protection system (2016-2020), there were three occurrences of a lightning strike on the PV power plant. The ESE lightning protection system effectively protected and prevented the lightning strike to the PV power plant. This study can help and support with the selection of a lightning system for the protection of large scale PV power plants in the future.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Impact of Large-Scale PV Penetration on Power System Oscillatory Stability
    Shah, Rakibuzzaman
    Mithulananthan, Nadarajah
    Arthit-Sode-Yome
    Lee, Kwang. Y.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [32] Comparison of large scale solar PV (photovoltaic) and nuclear power plant investments in an emerging market
    Karaveli, Abdullah Bugrahan
    Soytas, Ugur
    Akinoglu, Bulent G.
    ENERGY, 2015, 84 : 656 - 665
  • [33] Three-level AGC for Large-scale PV Power Plant with String Inverters
    Wang Shuchao
    Duan Shengpeng
    Hou Wei
    Chen Jun
    Zhao Xicai
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2016,
  • [34] Supplementary Damping Control Design for Large Scale PV Power Plant at Transmission Level Interconnection
    Isbeih, Younes J.
    El Moursi, Mohamed Shawky
    Lotfi, Mohamed
    Catalao, Joao P. S.
    Abdel-Rahman, Mansour H.
    2020 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE 2020): SMART GRIDS: KEY ENABLERS OF A GREEN POWER SYSTEM, 2020, : 625 - 629
  • [35] Risk Analysis of the Lightning-Related Transients on Photovoltaic Systems: Application to a Solar Power Plant Without a Lightning Protection System
    Kermani, B.
    Shariatinasab, R.
    Khorshidi, M.
    He, Jinliang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (01) : 618 - 629
  • [36] Survey of Fault Analysis and Protection for Power System with Large Scale Power Electronic Equipments
    Song G.
    Tao R.
    Li B.
    Hu J.
    Wang C.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2017, 41 (12): : 2 - 12
  • [37] Analysis of the Lightning Transient Response of the Earthing System of Large-Scale Ground-Mounted PV Plants
    Araneo, Rodolfo
    Maccioni, Marco
    Lauria, Stefano
    Celozzi, Salvatore
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [38] Methods to Optimize the Performance of an Existing Large-Scale On-grid Solar PV Plant
    Umesh, Suma
    Chaithra, J.
    Deborah, G.
    Gayathri, J.
    Pruthvi, N.
    EMERGING RESEARCH IN ELECTRONICS, COMPUTER SCIENCE AND TECHNOLOGY, ICERECT 2018, 2019, 545 : 1407 - 1436
  • [39] A review of key power system stability challenges for large-scale PV integration
    Shah, Rakibuzzaman
    Mithulananthan, N.
    Bansal, R. C.
    Ramachandaramurthy, V. K.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 41 : 1423 - 1436
  • [40] Harmonic Analysis on Power Grid of Large Scale PV Grid-connected System
    Fu, Xixi
    Wen, Jun
    Liu, Tingting
    Ji, Cheng
    PROCEEDINGS OF 2014 IEEE WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS (WARTIA), 2014, : 1346 - 1349