Five-Year Performance of an ESE Lightning Protection System for a Large Scale PV Power Plant in Thailand

被引:1
|
作者
Kongnok, Rungphet [1 ]
Pummaitong, Thanakorn [1 ]
Plangklang, Boonyang [1 ]
机构
[1] Rajamangala Univ Technol Thanyaburi, Dept Elect Engn, Fac Engn, 39 Moo 1,Klong 6, Khlong Luang 12110, Pathum Thani, Thailand
来源
SYMMETRY-BASEL | 2021年 / 13卷 / 11期
关键词
Franklin lightning protection; ESE lightning protection; PV power plant; STROKE;
D O I
10.3390/sym13112106
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This article presents a five-year performance review of an early streamer emission (ESE) air terminal lightning protection system for a large scale PV power plant in Thailand. The comparison effect of a Franklin lightning protection system and the ESE lightning protection system was analyzed for the PV power plant. The ESE lightning protection system was selected to be implemented in the PV power plant. The capacity of the PV power plant studied was 8 MWp on an area of 150,000 square meters in the Nong Ya Plong district, Phetchaburi province, Western Thailand. A Franklin lightning rod type was also designed to be implemented in this PV power plant. The Franklin lightning rod type comprised 122 pieces but the ESE lightning rod type consisted of only 11 pieces. The conceptual design of the Franklin rod type followed the standard of the Council of Engineers, Thailand, and the ESE lightning rod type followed the NFC17102 standard of France. The estimated cost of installation was a key comparison to select the lightning protection system; the total installation cost of the Franklin lightning rod type was USD 197,363.80 and the ESE lightning rod type was USD 44,338.06. The lightning system was applied to the lightning arrester in the power plant to provide good protection, in which the balance of the pole to the mounting position is required to optimize the system performance. The result of the simulation also showed that the shading effects of the Franklin rod type were greater than the ESE rod type. The installation cost of the Franklin lightning rod type was 4.45 times more expensive than the ESE lightning rod type. Therefore, the ESE lightning protection system was selected to be implemented in the PV power plant. From the recorded data of the five-year performance of the ESE lightning protection system (2016-2020), there were three occurrences of a lightning strike on the PV power plant. The ESE lightning protection system effectively protected and prevented the lightning strike to the PV power plant. This study can help and support with the selection of a lightning system for the protection of large scale PV power plants in the future.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A protection scheme for the transmission line connecting large-scale centralized solar PV plant
    Singh, Sikander
    Nayak, Paresh Kumar
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2024,
  • [22] A guide in installing large-scale PV power plant for self consumption mechanism
    Senol, M.
    Abbasoglu, S.
    Kukrer, O.
    Babatunde, A. A.
    SOLAR ENERGY, 2016, 132 : 518 - 537
  • [23] Large-Scale PV Plant With a Robust Controller Considering Power Oscillation Damping
    Shah, Rakibuzzaman
    Mithulananthan, Nadarajah
    Lee, Kwang Y.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (01) : 106 - 116
  • [24] Effect of Solar Tracking on the Economic Viability of a Large-Scale PV Power Plant
    Agyekum, Ephraim Bonah
    Afornu, Bright Kwame
    Ansah, Michael Nii Sanka
    ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2020, 24 (03) : 55 - 65
  • [25] Design of Robust Power Oscillation Damping Controller for Large-scale PV Plant
    Shah, Rakibuzzaman
    Mithulananathan, N.
    Lee, Kwang Y.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [26] Proposal of unique PV system for large-scale photovoltaic power generation system
    Fukae, K
    Takabayashi, A
    Itoyama, S
    Kataoka, I
    Makita, H
    Matsushita, M
    Mukai, T
    Takehara, N
    Konishi, M
    PROCEEDINGS OF 3RD WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION, VOLS A-C, 2003, : 2815 - 2820
  • [27] Performance evaluation of a 10 kWp PV power system prototype for isolated building in Thailand
    Sasitharanuwat, Achitpon
    Rakwichian, Wattanapong
    Ketjoy, Nipon
    Yammen, Suchart
    RENEWABLE ENERGY, 2007, 32 (08) : 1288 - 1300
  • [28] Heart transplantation performance in China: Five-year experience after transplantation system reform
    Lin Shen
    Chen Sipeng
    Zheng Shanshan
    Liu Sheng
    Huang Jie
    Shi Ying
    Wang Haibo
    Zheng Zhe
    China Heart Transplant Registry Collaborative Group
    中华医学杂志英文版, 2025, 138 (05)
  • [29] Active control-based protection for a flexible DC system of a PV power plant
    Zhu, Rui
    Jia, Ke
    Bi, Tian-shu
    Zhao, Qijuan
    Wang, Cong-bo
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114
  • [30] Performance evaluation and analysis of grid-tied large scale PV plant in Algeria
    Dahmoun, Mouhcen El-Hadi
    Bekkouche, Bennaissa
    Sudhakar, K.
    Guezgouz, Mohammed
    Chenafi, Abdessalam
    Chaouch, Abdellah
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2021, 61 : 181 - 195