The Application of a New Model-Based Iterative Reconstruction in Low-Dose Upper Abdominal CT

被引:7
|
作者
Jia, Yongjun [1 ]
Zhai, Bingying [2 ]
He, Taiping [1 ]
Yu, Yong [1 ]
Yu, Nan [1 ]
Duan, Haifeng [1 ]
Yang, Chuangbo [1 ]
Zhang, Xirong [1 ]
机构
[1] Shaanxi Chinese Med Univ, Dept Radiol, Affiliated Hosp, 2 Weiyang West Rd, Xianyang 712000, Shaanxi, Peoples R China
[2] Yanan Univ, Xianyang Hosp, Dept Crit Care Med, Xianyang, Peoples R China
关键词
Model-based iterative reconstruction; Adaptive statistical iterative reconstruction; Radiation dose; X-ray computed tomography; Abdominal CT; FILTERED BACK-PROJECTION; IMAGE QUALITY; HYBRID; MBIR;
D O I
10.1016/j.acra.2018.11.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare upper abdominal computed tomography (CT) image quality of new model-based iterative reconstruction (MBIR) with low-contrast resolution preference (MBIRNR40), conventional MBIR (MBIRc), and adaptive statistical iterative reconstruction (ASIR) at low dose with ASIR at routine-dose. Materials and Methods: Study included phantom and 60 patients who had initial and follow-up CT scans. For patients, the delay phase was acquired at routine-dose (noise index = 10 HU) for the initial scan and low dose (noise index = 20 HU) for the follow-up. The low-dose CT was reconstructed with 40% and 60% ASIR, MBIRc, and MBIRNR40, while routine-dose CT was reconstructed with 40% ASIR. CT value and noise measurements of the subcutaneous fat, back muscle, liver, and spleen parenchyma were compared using one-way ANOVA. Two radiologists used semiquantitative 7-scale (<inverted exclamation>3 to +3) to rate image quality and artifacts. Results: The phantom study revealed superior low-contrast resolution with MBIRNR40. For patient scans, the CT dose index for the lowdose CT was 3.00 +/- 1.32 mGy, 75% lower than the 11.90 +/- 4.75 mGy for the routine-dose CT. Image noise for the low-dose MBIRNR40 images was significantly lower than the low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Subjective ratings showed higher image quality for low-dose MBIRNR40, with lower noise, better low-contrast resolution for abdominal structures, and finer lesion contours than those of low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Conclusion: MBIRNR40 with low-contrast resolution preference provides significantly lower noise and better image quality than MBIRc and ASIR in low-dose abdominal CT; significantly better objective and subjective image quality than the routine-dose ASIR with 75% dose reduction.
引用
收藏
页码:E275 / E283
页数:9
相关论文
共 50 条
  • [31] Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction
    Wellenberg, R. H. H.
    Boomsma, M. F.
    van Osch, J. A. C.
    Vlassenbroek, A.
    Milles, J.
    Edens, M. A.
    Streekstra, G. J.
    Slump, C. H.
    Maas, M.
    SKELETAL RADIOLOGY, 2017, 46 (05) : 623 - 632
  • [32] Usefulness of model-based iterative reconstruction in low-dose lumbar spine CT after spine surgery with metal implant: a phantom study
    Fukushima, Yasuhiro
    Matsuda, Akira
    Koizumi, Koji
    Honda, Maya
    Masamoto, Kazutaka
    Fujibayashi, Shunsuke
    ACTA RADIOLOGICA, 2021, 62 (10) : 1333 - 1340
  • [33] Reduction of CT Exposure for Low-Dose CT Imaging by Iterative CT Reconstruction
    Grosser, O. S.
    Czuczwara, D.
    Wissel, H.
    Laatz, K.
    Ulrich, G.
    Furth, C.
    Ruf, J.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S501 - S501
  • [34] Ultra-Low-Dose Fetal CT With Model-Based Iterative Reconstruction: A Prospective Pilot Study
    Imai, Rumi
    Miyazaki, Osamu
    Horiuchi, Tetsuya
    Asano, Keisuke
    Nishimura, Gen
    Sago, Haruhiko
    Nosaka, Shunsuke
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (06) : 1358 - 1365
  • [35] Fast iterative adaptive reconstruction in low-dose CT imaging
    Cheng, Lin
    Chen, Yunqiang
    Fang, Tong
    Tyan, Jason
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 889 - +
  • [36] Investigation of iterative image reconstruction in low-dose breast CT
    Bian, Junguo
    Yang, Kai
    Boone, John M.
    Han, Xiao
    Sidky, Emil Y.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2659 - 2685
  • [37] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [38] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [39] Feasibility of an ultra low dose CT for left atrium and pulmonary veins imaging using a new model-based iterative reconstruction
    Annoni, A.
    Andreini, D.
    Formenti, A.
    Pontone, G.
    Mushtaq, S.
    Bertella, E.
    Petulla, M.
    Nobili, E.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 200 - 200
  • [40] Iterative Reconstruction for Low-Dose CT Using Deep Gradient Priors of Generative Model
    He, Zhuonan
    Zhang, Yikun
    Guan, Yu
    Guan, Bing
    Niu, Shanzhou
    Zhang, Yi
    Chen, Yang
    Liu, Qiegen
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (07) : 741 - 754