The Application of a New Model-Based Iterative Reconstruction in Low-Dose Upper Abdominal CT

被引:7
|
作者
Jia, Yongjun [1 ]
Zhai, Bingying [2 ]
He, Taiping [1 ]
Yu, Yong [1 ]
Yu, Nan [1 ]
Duan, Haifeng [1 ]
Yang, Chuangbo [1 ]
Zhang, Xirong [1 ]
机构
[1] Shaanxi Chinese Med Univ, Dept Radiol, Affiliated Hosp, 2 Weiyang West Rd, Xianyang 712000, Shaanxi, Peoples R China
[2] Yanan Univ, Xianyang Hosp, Dept Crit Care Med, Xianyang, Peoples R China
关键词
Model-based iterative reconstruction; Adaptive statistical iterative reconstruction; Radiation dose; X-ray computed tomography; Abdominal CT; FILTERED BACK-PROJECTION; IMAGE QUALITY; HYBRID; MBIR;
D O I
10.1016/j.acra.2018.11.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare upper abdominal computed tomography (CT) image quality of new model-based iterative reconstruction (MBIR) with low-contrast resolution preference (MBIRNR40), conventional MBIR (MBIRc), and adaptive statistical iterative reconstruction (ASIR) at low dose with ASIR at routine-dose. Materials and Methods: Study included phantom and 60 patients who had initial and follow-up CT scans. For patients, the delay phase was acquired at routine-dose (noise index = 10 HU) for the initial scan and low dose (noise index = 20 HU) for the follow-up. The low-dose CT was reconstructed with 40% and 60% ASIR, MBIRc, and MBIRNR40, while routine-dose CT was reconstructed with 40% ASIR. CT value and noise measurements of the subcutaneous fat, back muscle, liver, and spleen parenchyma were compared using one-way ANOVA. Two radiologists used semiquantitative 7-scale (<inverted exclamation>3 to +3) to rate image quality and artifacts. Results: The phantom study revealed superior low-contrast resolution with MBIRNR40. For patient scans, the CT dose index for the lowdose CT was 3.00 +/- 1.32 mGy, 75% lower than the 11.90 +/- 4.75 mGy for the routine-dose CT. Image noise for the low-dose MBIRNR40 images was significantly lower than the low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Subjective ratings showed higher image quality for low-dose MBIRNR40, with lower noise, better low-contrast resolution for abdominal structures, and finer lesion contours than those of low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Conclusion: MBIRNR40 with low-contrast resolution preference provides significantly lower noise and better image quality than MBIRc and ASIR in low-dose abdominal CT; significantly better objective and subjective image quality than the routine-dose ASIR with 75% dose reduction.
引用
收藏
页码:E275 / E283
页数:9
相关论文
共 50 条
  • [21] Application of low-dose CT combined with model-based iterative reconstruction algorithm in oncologic patients during follow-up: dose reduction and image quality
    Ippolito, Davide
    Maino, Cesare
    Pecorelli, Anna
    Salemi, Ilaria
    Gandola, Davide
    Riva, Luca
    Franzesi, Cammillo Talei
    Sironi, Sandro
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1124):
  • [22] Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose
    Aurumskjold, Marie-Louise
    Soderberg, Marcus
    Stalhammar, Fredrik
    von Steyern, Kristina Vult
    Tingberg, Anders
    Ydstrom, Kristina
    ACTA RADIOLOGICA, 2018, 59 (06) : 740 - 747
  • [23] Forward-Projected Model-Based Iterative Reconstruction in Screening Low-Dose Chest CT: Comparison With Adaptive Iterative Dose Reduction 3D
    Hassani, Cameron
    Ronco, Anthony
    Prosper, Ashley E.
    Dissanayake, Sumudu
    Cen, Steven Y.
    Lee, Christopher
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 548 - 556
  • [24] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [25] Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction
    Lee, Sun Hwa
    Yun, Seong Jong
    Jo, Hyeon Hwan
    Song, Jae Gwang
    CLINICAL IMAGING, 2018, 50 : 216 - 222
  • [26] Reduced Radiation Dose with Model-based Iterative Reconstruction versus Standard Dose with Adaptive Statistical Iterative Reconstruction in Abdominal CT for Diagnosis of Acute Renal Colic
    Fontarensky, Mikael
    Alfidja, Agaicha
    Perignon, Renan
    Schoenig, Arnaud
    Perrier, Christophe
    Mulliez, Aurelien
    Guy, Laurent
    Boyer, Louis
    RADIOLOGY, 2015, 276 (01) : 156 - 166
  • [27] Effects of Model-Based Iterative Reconstruction in Low-Dose Paranasal Computed Tomography: A Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction
    Tomita, Hayato
    Kuramochi, Kenji
    Fujikawa, Atsuko
    Ikeda, Hirotaka
    Komita, Midori
    Kurihara, Yoshiko
    Kobayashi, Yasuyuki
    Mimura, Hidefumi
    ACTA MEDICA OKAYAMA, 2022, 76 (05) : 511 - 517
  • [28] Multiclass Dictionary-Based Statistical Iterative Reconstruction for Low-Dose CT
    Kamoshita, Hiryu
    Kitahara, Daichi
    Fujimoto, Ken'ichi
    Condat, Laurent
    Hirabayashi, Akira
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2021, E104A (04) : 702 - 713
  • [29] Model-Based Iterative Reconstruction in CT Enterography
    Murphy, Kevin P.
    Crush, Lee
    Twomey, Maria
    McLaughlin, Patrick D.
    Mildenberger, Iris C.
    Moore, Niamh
    Bye, Jackie
    O'Connor, Owen J.
    McSweeney, Sean E.
    Shanahan, Fergus
    Maher, Michael M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (06) : 1173 - 1181
  • [30] Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction
    R. H. H. Wellenberg
    M. F. Boomsma
    J. A. C. van Osch
    A. Vlassenbroek
    J. Milles
    M. A. Edens
    G. J. Streekstra
    C. H. Slump
    M. Maas
    Skeletal Radiology, 2017, 46 : 623 - 632