A non-dimensional analysis of a ventilated double facade energy performance

被引:58
|
作者
Balocco, C [1 ]
机构
[1] Univ Florence, Dipartimento Energet S Stecco, Florence, Italy
关键词
non-dimensional numbers; ventilated double facade; simulation;
D O I
10.1016/S0378-7788(03)00086-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A method based on dimensional analysis is proposed for a natural ventilated double facade energy performance study. The 14 non-dimensional numbers defined, with physical meaning, can be used to describe thermal and energy performance of different facade designs. A comparison between non-dimensional numbers solved by simulation, experimental data, and the obtained and validated correlation results is reported. A simple tool to evaluate thermal performance of a solar chimney is provided. Applying it, useful design indications can be derived also by varying simple parameters using thermal and physical data easy to get. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [1] Thermal behaviour of interactive mechanically ventilated double glazed facade: Non-dimensional analysis
    Balocco, C
    Colombari, M
    ENERGY AND BUILDINGS, 2006, 38 (01) : 1 - 7
  • [2] Energy performance of the opaque ventilated facade
    Fribar-Solaberrieta, E.
    Escudero-Revilla, C.
    Odriozola-Maritorena, M.
    Campos-Celador, A. .
    Garcia-Gafaro, C.
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 55 - 60
  • [3] Energy performance of a ventilated double skin facade with PCM under different climates
    de Gracia, Alvaro
    Navarro, Lidia
    Castell, Albert
    Cabeza, Luisa F.
    ENERGY AND BUILDINGS, 2015, 91 : 37 - 42
  • [4] Non-dimensional analysis of the performance of semiactive vehicle suspensions
    Ahmadian, Mehdi
    Blanchard, Emmanuel
    19TH INTERNATIONAL CONFERENCE ON DESIGN THEORY AND METHODOLOGY/1ST INTERNATIONAL CONFERENCE ON MICRO AND NANO SYSTEMS, VOL 3, PART A AND B, 2008, : 1271 - 1277
  • [5] Energy performance of a ventilated facade by simulation with experimental validation
    Aparicio-Fernandez, Carolina
    Vivancos, Jose-Luis
    Ferrer-Gisbert, Pablo
    Royo-Pastor, Rafael
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 563 - 570
  • [6] A Non-dimensional analysis of hemodialysis
    Bonert M.
    Saville B.A.
    Open Biomedical Engineering Journal, 2010, 4 : 138 - 155
  • [7] Design and overall energy performance of a ventilated photovoltaic facade
    Yun, Geun Young
    McEvoy, Mike
    Steemers, Koen
    SOLAR ENERGY, 2007, 81 (03) : 383 - 394
  • [8] PERFORMANCE EVALUATION AND OPTIMIZATION OF VENTILATED DOUBLE SKIN FACADE IN CHINA
    Zhou, Hao
    Xiong, Chenguang
    Huang, Yichun
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 502 - 509
  • [9] Performance of ventilated double-sided PV facade compared with conventional clear glass facade
    Han, Jun
    Lu, Lin
    Peng, Jinqing
    Yang, Hongxing
    ENERGY AND BUILDINGS, 2013, 56 : 204 - 209
  • [10] Analysis of the energy performance of an Opaque Ventilated Facade under winter and summer weather conditions