Performance of ventilated double-sided PV facade compared with conventional clear glass facade

被引:85
|
作者
Han, Jun [1 ,2 ]
Lu, Lin [1 ]
Peng, Jinqing [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Renewable Energy Res Lab, Kowloon, Hong Kong, Peoples R China
[2] CSIRO, CSIRO Div Ecosyst Sci, Highett, Vic 3190, Australia
关键词
PV facade (PVF); Conventional facade (CF); Thin-film solar cells; Heat gain; Power generation; HEAT-TRANSFER; AIR-FLOW; THERMAL PERFORMANCE; BIPV; WINDOW; CELLS;
D O I
10.1016/j.enbuild.2012.08.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The outdoor performance of a naturally ventilated double-sided PV facade was evaluated through field monitoring from a small scale test rig. The comparison of its thermal performance with that of a conventional clear glass facade with shield was made through the field measurement. The measured data show that the maximum indoor air temperature for conventional facade is close to 34 degrees C, while 29 degrees C only for PV facades under same summer weather conditions. This indicates that heat gain to building in summer could be substantially reduced and additional electrical power could also be generated from such facade as a byproduct. In addition, the temperature influence on thin-film solar cells was tested. The effect of temperature on the conversion efficiency of thin-film amorphous silicon solar cell is found small. It is observed that a reduction of 15.6 degrees C in module temperature of the thin-film solar cell only leads to a decrease of 0.29% in conversion efficiency. However, the ventilation cooling of PV reduce the possibility of potential overheating problems when PV is integrated into building as an external facade, especially in extreme hot weather conditions. In addition, the internal heat gain could be considerably reduced compared with conventional clear glass facade with shield in summer. A better thermal comfort of indoor occupants thus could be anticipated in the present proposed facade system. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [1] Energy performance of an open-joint ventilated facade compared with a conventional sealed cavity facade
    Sanjuan, Cristina
    Jose Suarez, Maria
    Gonzalez, Marcos
    Pistono, Jorge
    Blanco, Eduardo
    [J]. SOLAR ENERGY, 2011, 85 (09) : 1851 - 1863
  • [2] Improved Performance of a PV Integrated Ventilated Facade at an Existing nZEB
    Tejero-Gonzalez, Ana
    Krawczyk, Dorota Anna
    Garcia, Jose Ramon Martin-Sanz
    Javier Rey-Martinez, Francisco
    Velasco-Gomez, Eloy
    [J]. ENERGIES, 2019, 12 (15)
  • [3] PERFORMANCE EVALUATION AND OPTIMIZATION OF VENTILATED DOUBLE SKIN FACADE IN CHINA
    Zhou, Hao
    Xiong, Chenguang
    Huang, Yichun
    [J]. 2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 502 - 509
  • [4] Thermal modelling of a building with an integrated ventilated PV facade
    Mei, L
    Infield, D
    Eicker, U
    Fux, V
    [J]. ENERGY AND BUILDINGS, 2003, 35 (06) : 605 - 617
  • [5] Energy performance of the opaque ventilated facade
    Fribar-Solaberrieta, E.
    Escudero-Revilla, C.
    Odriozola-Maritorena, M.
    Campos-Celador, A. .
    Garcia-Gafaro, C.
    [J]. 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 55 - 60
  • [7] Ventilation performance of a naturally ventilated double-skin facade in buildings
    Tao, Yao
    Zhang, Haihua
    Zhang, Lili
    Zhang, Guomin
    Tu, Jiyuan
    Shi, Long
    [J]. RENEWABLE ENERGY, 2021, 167 : 184 - 198
  • [8] An evolutionary approach to single-sided ventilated facade design
    Marzban, Samin
    Ding, Lan
    Fiorito, Francesco
    [J]. INTERNATIONAL HIGH-PERFORMANCE BUILT ENVIRONMENT CONFERENCE - A SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2016 SERIES (SBE16), IHBE 2016, 2017, 180 : 582 - 590
  • [9] Experimental and numerical studies to assess the energy performance of naturally ventilated PV facade systems
    Shahrestani, Mehdi
    Yao, Runming
    Essah, Emmanuel
    Shao, Li
    Oliveira, Armando C.
    Hepbasli, Arif
    Biyik, Emrah
    del Cano, Teodosio
    Rico, Elena
    Luis Lechon, Juan
    [J]. SOLAR ENERGY, 2017, 147 : 37 - 51
  • [10] Experimental and numerical study of a mechanically ventilated glass double facade with integrated shading device
    Manz, H
    Simmler, H
    [J]. RESEARCH IN BUILDING PHYSICS, 2003, : 519 - 526