A non-dimensional analysis of a ventilated double facade energy performance

被引:58
|
作者
Balocco, C [1 ]
机构
[1] Univ Florence, Dipartimento Energet S Stecco, Florence, Italy
关键词
non-dimensional numbers; ventilated double facade; simulation;
D O I
10.1016/S0378-7788(03)00086-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A method based on dimensional analysis is proposed for a natural ventilated double facade energy performance study. The 14 non-dimensional numbers defined, with physical meaning, can be used to describe thermal and energy performance of different facade designs. A comparison between non-dimensional numbers solved by simulation, experimental data, and the obtained and validated correlation results is reported. A simple tool to evaluate thermal performance of a solar chimney is provided. Applying it, useful design indications can be derived also by varying simple parameters using thermal and physical data easy to get. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [31] Ventilated Facade with double chamber and flow control device
    Cruz Astorqui, Jaime Santa
    Porras-Amores, Cesar
    ENERGY AND BUILDINGS, 2017, 149 : 471 - 482
  • [32] Modeling ventilated double skin facade - A zonal approach
    Jiru, Teshome Edae
    Haghighat, Fariborz
    ENERGY AND BUILDINGS, 2008, 40 (08) : 1567 - 1576
  • [33] Non-dimensional analysis of an unsteady flow in a magnetorheological damper
    Shou, Mengjie
    Xie, Lei
    Li, Rui
    Liao, Changrong
    PHYSICS OF FLUIDS, 2022, 34 (08)
  • [34] Non-dimensional analysis of shot peening by means of DoE
    Baragetti, S.
    Terranova, A.
    International Journal of Materials and Product Technology, 2000, 15 (01) : 131 - 141
  • [35] Non-dimensional analysis of experimental pressure drop and energy dissipation measurements in Oscillatory Baffled Reactors
    Munoz-Camara, J.
    Solano, J. P.
    Perez-Garcia, J.
    CHEMICAL ENGINEERING SCIENCE, 2022, 262
  • [36] Thermal performance analysis of naturally ventilated and perforated sheet based double skin facade system for hot summer conditions
    Sharma M.K.
    Preet S.
    Mathur J.
    Chowdhury A.
    Mathur S.
    International Journal of Ventilation, 2022, 21 (04): : 263 - 283
  • [37] Design enhancement and non-dimensional analysis of magnetically-levitated nonlinear vibration energy harvesters
    Nammari, Abdullah
    Bardaweel, Hamzeh
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2017, 28 (19) : 2810 - 2822
  • [38] Experimental and numerical studies to assess the energy performance of naturally ventilated PV facade systems
    Shahrestani, Mehdi
    Yao, Runming
    Essah, Emmanuel
    Shao, Li
    Oliveira, Armando C.
    Hepbasli, Arif
    Biyik, Emrah
    del Cano, Teodosio
    Rico, Elena
    Luis Lechon, Juan
    SOLAR ENERGY, 2017, 147 : 37 - 51
  • [39] Composite polymeric materials as an alternative to aluminium for improved energy performance of ventilated facade systems
    Arregi, Benat
    Elguezabal, Peru
    Alvarez, Izaskun
    CLIMATE RESILIENT CITIES - ENERGY EFFICIENCY & RENEWABLES IN THE DIGITAL ERA (CISBAT 2019), 2019, 1343
  • [40] Double skin facade: energy performance in the United Arab Emirates
    Aldawoud, Abdelsalam
    Salameh, Tareq
    Kim, Young Ki
    ENERGY SOURCES PART B-ECONOMICS PLANNING AND POLICY, 2021, 16 (05) : 387 - 405